ASTM D3866-2007 Standard Test Methods for Silver in Water《水中银含量的标准测试方法》.pdf
《ASTM D3866-2007 Standard Test Methods for Silver in Water《水中银含量的标准测试方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3866-2007 Standard Test Methods for Silver in Water《水中银含量的标准测试方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3866 07Standard Test Methods forSilver in Water1This standard is issued under the fixed designation D 3866; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates
2、 the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the atomic absorption deter-mination of silver in water. Three test methods are given asfollows:ConcentrationRange SectionsTest Method AAtom
3、ic Absorp-tionChelation-ExtractionA1to10g/L 7to15Test Method BAtomic Absorp-tionDirect0.1to10mg/L 16to24Test Method CAtomic Absorp-tionGraphite Furnace1to25g/L 25to33ASimilar to that in Brown, E., Skougstad, M. W., and Fishman, M. J., “Methodsfor Collection and Analysis of Water Samples for Dissolve
4、d Minerals and Gases,”Techniques of Water-Resources Investigations of the U.S. Geological Survey,Book 5, Chapter A1, 1970, p. 46.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish
5、 appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific precau-tionary statements are given in Note 3, Note 5, Note 9, andNote 13.2. Referenced Documents2.1 ASTM Standards:2D 1129 Terminology Relating to WaterD 1193 Specification fo
6、r Reagent WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Test Methods of Committee D19 on WaterD 3370 Practices for Sampling Water from Closed ConduitsD 3919 Practice for Measuring Trace Elements in Water byGraphite Furnace Atomic Absorption SpectrophotometryD 4691 Practic
7、e for Measuring Elements in Water by FlameAtomic Absorption SpectrophotometryD 4841 Practice for Estimation of Holding Time for WaterSamples Containing Organic and Inorganic ConstituentsD 5810 Guide for Spiking into Aqueous SamplesD 5847 Practice for Writing Quality Control Specificationsfor Standar
8、d Test Methods for Water Analysis3. Terminology3.1 Definition of Term Specific to These Test Methods:3.1.1 laboratory control sample, na solution with a cer-tified concentration of silver.3.1.2 total recoverable silveran arbitrary analytical termrelating to forms of silver that are determinable by t
9、hedigestion method that is included in the procedures.3.2 DefinitionsFor definition of terms used in these testmethods, refer to Terminology D 1129.4. Significance and Use4.1 The principal adverse effect of silver in the body iscosmetic. It causes argyria, a permanent, blue-gray discolora-tion of th
10、e skin, eyes, and mucous membranes.4.2 Relatively small quantities of silver are bactericidal orbacteriostatic and find limited use in both disinfection ofswimming pool waters and point-of-use water filters.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise
11、indicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReagents of the American Chemical Society, when suchspecifications are available.3Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to
12、 permit its use without lessening the accuracy ofthe determination.5.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean reagent water conformingto Specification D 1193, Type I, II, or III water. Type I ispreferred and more commonly used. Other reagent water t
13、ypesmay be used provided it is first ascertained that the water is of1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.05 on InorganicConstituents in Water.Current edition approved Aug. 1, 2007. Published August 2007. O
14、riginallyapproved in 1979. Last previous edition approved in 2002 as D 3866 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page o
15、nthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United
16、 States Pharmacopeiaand National Formulary, U.S. Pharmacopeial Convention, Inc. (USPC), Rockville,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.sufficiently high purity to permit its use without adverselyaffecting the precision
17、and bias of the test method. Type IIwater was specified at the time of round robin testing of thesetest methods.NOTE 1The user must ensure the type of reagent water chosen issufficiently free of interferences. The water should be analyzed using thetest method.6. Sampling6.1 Collect the sample in acc
18、ordance with Practices D 3370.The holding time for the samples may be calculated inaccordance with Practice D 4841.6.2 Preserve samples for Test Method A with HNO3(sp gr1.42) to a pH of 2 or less immediately at the time of collection;normally about 2 mL/L is required. If only dissolved silver isto b
19、e determined, filter the sample at time of collection througha 0.45-m membrane filter before acidification.6.3 Do not preserve samples for Test Methods B and C atthe time of collection. If only dissolved silver is to bedetermined, filter the sample through a 0.45-m membranefilter at time of collecti
20、on.Add cyanogen iodide (CNI) solutionto the samples in the laboratory prior to analysis. For totalrecoverable silver it is preferable to add the cyanogen iodide tothe entire sample to avoid a nonhomogeneous solution; there-fore, it is advisable to collect a discrete sample for silver.TEST METHOD AAT
21、OMIC ABSORPTIONCHELATION EXTRACTION7. Scope7.1 This test method4covers the determination of dissolvedand total recoverable silver in most water and wastewaters.7.2 This test method is applicable in the range from 1 to 10g/L of silver. The range may be extended by dilution of theoriginal sample.7.3 T
22、his test method has been used successfully withreagent water, natural surface water, and drinking water. Theinformation on precision and bias may not apply to otherwaters. It is the users responsibility to ensure the validity ofthis test method for waters of untested matrices.8. Summary of Test Meth
23、od8.1 Silver is determined by atomic absorption spectrometry.The element, either dissolved or total recoverable, is chelatedwith ammonium pyrrolidine dithiocarbamate (APDC) andextracted with methyl isobutyl ketone (MIBK). The extract isaspirated into an air-acetylene flame of the spectrophotometer.T
24、otal recoverable silver is determined following nitric aciddigestion and filtration.9. Interferences9.1 Concentrations of iron greater than 25 mg/L interfere bysuppressing the silver absorption.10. Apparatus10.1 Atomic Absorption Spectrophotometer for use at 328.1nm. A general guide for the use of f
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD38662007STANDARDTESTMETHODSFORSILVERINWATER 水中 含量 标准 测试 方法 PDF

链接地址:http://www.mydoc123.com/p-515669.html