1、Designation: D 3833/D 3833M 96 (Reapproved 2006)Standard Test Method forWater Vapor Transmission of Pressure-Sensitive Tapes1This standard is issued under the fixed designation D 3833/D 3833M; the number immediately following the designation indicates theyear of original adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test meth
3、od covers one procedure for measuringthe water vapor transmission rate of pressure-sensitive tape.1.2 The values stated in either SI or inch-pound units are tobe regarded separately as standard. The values stated in eachsystem may not be exact equivalents; therefore, each systemmust be used independ
4、ently, without combining values in anyway.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulator
5、y limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 996 Terminology of Packaging and Distribution Environ-mentsD 3715/D 3715M Practice for Quality Assurance ofPressure-Sensitive TapesD 4332 Practice for Conditioning Containers, Packages, orPackaging Components for TestingE 96/E 96
6、M Test Methods for Water Vapor Transmission ofMaterialsE 122 Practice for Calculating Sample Size to Estimate,With a Specified Tolerable Error, the Average for aCharacteristic of a Lot or Process3. Terminology3.1 DefinitionsGeneral terms in this test method aredefined in Terminology D 996.4. Summary
7、 of Test Method4.1 The pressure-sensitive tape is secured by its adhesive toa test cup containing a desiccant. The assembly is exposed toa controlled atmosphere and weighed after two intervals of thatexposure. The gain in weight is used to calculate the watervapor transmission rate (WVTR).5. Signifi
8、cance and Use5.1 The results of this test method will indicate the relativepermeability by water vapor of the tape through its smallestdimension (generally normal to the tapes backing).5.1.1 The pathway for the water vapor parallel to theadhesive-cup interface is great compared to the tapes thick-ne
9、ss and the latter is usually the nearly exclusive source oftransmitted vapor.5.1.2 Some tape types allow a relatively free path in adirection normal to the backing or along backing pathwaysparallel to the adhesive-cup interface allowing the adhesive tobecome the principal barrier.5.2 If the adhesive
10、 does not continue to adhere to the cupflange during the exposure periods allowing unintended path-ways for water vapor to occur, the measurement should beconsidered as not having been made. Consequently, the tapemight be considered as being inappropriate for use on surfaceslike the cup flange under
11、 moisture conditions approximatingthose of the test.NOTE 1It may be that the interest is simply in the tape material as awater vapor barrier. In this case, how well the tape adheres to the cupflange may be of little consequence, and steps to prevent any edge effectsare in order. These are referred t
12、o in Section 10.6. Apparatus6.1 Test Cups,2made from materials that are nonhygro-scopic. The cup shall have a zero WVTR. The cups shall berectangular with a flat, smooth, rigid flange, and shall have thefollowing dimensions:Flange:Outside50.8 by 152.4 6 0.5mm2.0by6.06 0.02 in.Inside (opening)25.4 by
13、 101.6 6 0.5mm1.0by4.06 0.02 in.Body:Inside25.4 by 101.6 by 38.1 (depth) 6 0.5 mm 1.0 by 4.0 by 1.5 (depth) 60.02 in.1This test method is under the jurisdiction of ASTM Committee D10 onPackaging and is the direct responsibility of Subcommittee D10.14 on Tape andLabels.Current edition approved April
14、1, 2006. Published April 2006. Originallyapproved in 1979. Last previous edition approved in 2001 as D 3833/D 3833M 96(2001).2The sole source of supply of the apparatus known to the committee at this timeis Chemsultants International, 9349 Hamilton Dr., Mentor, OH 440611118. If youare aware of alter
15、native suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical committee,1which you may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 1942
16、8-2959, United States.The mass shall not exceed 80 % of the balance capacity usedin weighing.6.2 Calcium Chloride, anhydrous, passing a No. 8 (2.36-mm) sieve.NOTE 2Regenerate calcium chloride to a sufficiently anhydrous stateby heating it for2hatapproximately 200C 392F.6.3 Test Chamber, controlled a
17、t 90 to 95 % relative humid-ity at 38 6 1C 100.0 6 2.0F. The air shall be circulatedwithin the chamber to provide uniform conditions for allspecimens and shall give no visible condensation on the testcups.6.4 Balance, accurate to 61 mg.7. Sampling7.1 Acceptance SamplingSampling shall be in accordanc
18、ewith Practice D 3715/D 3715M.7.2 Sampling for Other PurposesThe sampling and thenumber of test specimens depends on the purpose of thetesting. Practice E 122 is recommended. It is common to test atleast five specimens of a particular tape. Test specimens shouldbe taken from several rolls of tape an
19、d wherever possible,among several production runs of a tape. Strong conclusionsabout a specific property of a tape cannot be based on testresults of a single unit (roll) of a product.8. Test Specimens8.1 Prepare three specimens for each sample or sample roll.8.2 Specimens shall be 50 minus 2.5 mm 2.
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD3833D3833M19962006STANDARDTESTMETHODFORWATERVAPORTRANSMISSIONOFPRESSURESENSITIVETAPES 压敏带 水蒸气 透过

链接地址:http://www.mydoc123.com/p-515591.html