《ASTM D3745-1995(2006) Standard Practice for Installation of Prefabricated Asphalt Reservoir Pond Canal and Ditch Liner (Exposed Type)《水库、池塘、渠、沟用预制沥青衬里(暴露型)安装的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3745-1995(2006) Standard Practice for Installation of Prefabricated Asphalt Reservoir Pond Canal and Ditch Liner (Exposed Type)《水库、池塘、渠、沟用预制沥青衬里(暴露型)安装的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3745 95 (Reapproved 2006)Standard Practice forInstallation of Prefabricated Asphalt Reservoir, Pond, Canal,and Ditch Liner (Exposed Type)1This standard is issued under the fixed designation D 3745; the number immediately following the designation indicates the year oforiginal adoption
2、 or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the description of suitable materialsand procedures fo
3、r installing prefabricated asphalt reservoir,pond, canal, and ditch liner (exposed type).1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practice
4、s and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D5 Test Method for Penetration of Bituminous MaterialsD6 Test Method for Loss on Heating of Oil and AsphalticCompoundsD36 Test Method for Softening Point of Bitumen (Ring-and-Ball App
5、aratus)D92 Test Method for Flash and Fire Points by ClevelandOpen Cup TesterD113 Test Method for Ductility of Bituminous MaterialsD 312 Specification for Asphalt Used in RoofingD 2042 Test Method for Solubility of Asphalt Materials inTrichloroethyleneD 2643 Specification for Prefabricated Asphalt Re
6、servoir,Pond, Canal, and Ditch Liner (Exposed Type)D 2822 Specification for Asphalt Roof Cement, Asbestos-Containing3. Terminology3.1 There are no terms in this practice that require new orother dictionary definitions.4. Significance and Use4.1 The practices described are only for water bearingreser
7、voirs, ponds, canals, and ditches.5. Materials5.1 The materials needed for the installation consist of thelining sheets, a joint sealant (either a hot-mopped asphalt or acold-applied asphalt mastic type), and batten or cover strips forthe joints between sheets; all of which are manufactured forcompa
8、tibility to prevent exudation.5.2 The lining sheets should conform to SpecificationD 2643.5.3 The hot-mopped asphalt joint sealant should conform toone of the following specifications:5.3.1 Specification D 312, Types II, III, or IV.5.3.1.1 The choice of which type of roofing asphalt to usefor a part
9、icular application will be influenced by climaticconditions and must be determined by the installer.5.3.2 An asphalt manufactured to the requirements in Table1.5.3.3 Test MethodsThe properties specified in Table 1may be determined as follows:5.3.3.1 Flash PointTest Method D92.5.3.3.2 Softening Point
10、Test Method D36.5.3.3.3 PenetrationTest Method D5.5.3.3.4 DuctilityTest Method D113.5.3.3.5 Weight LossTest Method D6.5.3.3.6 Asphalt Soluble in TrichloroethyleneTest MethodD 2042.5.4 The cold-applied joint sealant should meet the require-ments of Specification D 2822 and should have the approval of
11、the manufacturer of the lining material.1This practice is under the jurisdiction ofASTM Committee D08 on Roofing andWaterproofing and is the direct responsibility of Subcommittee D08.20 on RoofingMembrane Systems.Current edition approved Dec. 1, 2006. Published December 2006. Originallyapproved in 1
12、978. Last previous edition approved in 2000 as D 3745 95 (2000)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM web
13、site.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.5 The batten or cover strips should meet the requirementsof Specification D 2643, except with a minimum thickness of8 mm (5/16 in.) and a width of 203 mm (8 in.), unless othermat
14、erials or thicknesses are recommended by the lining manu-facturer or agreed upon between the purchaser and seller.6. Preparation of Subgrade6.1 Prepare the subgrade, whether soil, brick, concrete, orother substrate, by whatever means are necessary to removeany irregularities that might puncture or d
15、eform the lining.6.2 The subgrade should be designed to support the load ofthe particular installation under consideration. Compaction ofthe soil to give a minimum 95 % modified proctor density isrecommended.7. Cleaning the Liner Sheets7.1 Remove parting material from the lining prior to instal-lati
16、on. The cleaning equipment required will be determined bythe type of parting material used to separate the sheets duringshipment. Removal of some parting material may simply meanlifting off a sheet of paper or plastic. Other parting material,such as sand or mica, may require vigorous brushing withpo
17、wer equipment.7.2 CautionIf loose powdery material is involved, con-duct the cleaning process outside the installation area and wearsuitable protective equipment to prevent damage to the eyes orthe respiratory system.8. Installation of Bottom Lining in a Reservoir or Pond8.1 Lay the lining sheets in
18、 any pattern agreeable to thepurchaser and the installer. The following pattern has provensuccessful:8.1.1 Place a row of lining sheets on a line near the centerand parallel to the long side of the reservoir or pond. Lay thesheets end-to-end using butt-joints.8.1.2 Butt-joint succeeding rows adjacen
19、t to the first row,with transverse joints offset to the approximate midpoint of thesheets of each adjacent row.8.2 Seal the transverse and longitudinal joints using battenor cover strips and joint sealant. Use battens at least 305 mm(12 in.) longer than the joint to be covered. The ends oflongitudin
20、al cover strips should be overlapped 150 mm (6 in.)about midway between alternating perpendicular butt joints ofthe lining sheets.8.2.1 Apply joint sealant along all joints at least as wide asthe cover strips. If sealant application is by any method otherthan pouring (for example, mopping, troweling
21、, or spraying),apply another coat of sealant to the underside of the coverstrips.8.2.2 Position and press the cover strips immediately beforethe joint sealant solidifies. Apply sufficient pressure to forceout some of the sealant all along the edges.8.2.3 Point the ends of the batten strips with cold
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD374519952006STANDARDPRACTICEFORINSTALLATIONOFPREFABRICATEDASPHALTRESERVOIRPONDCANALANDDITCHLINEREXPOSEDTYPE

链接地址:http://www.mydoc123.com/p-515391.html