ASTM D3634-1999(2005)e1 Standard Test Method for Trace Chloride Ion in Engine Coolants《测定发动机冷却剂中痕量氯离子的试验方法》.pdf
《ASTM D3634-1999(2005)e1 Standard Test Method for Trace Chloride Ion in Engine Coolants《测定发动机冷却剂中痕量氯离子的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3634-1999(2005)e1 Standard Test Method for Trace Chloride Ion in Engine Coolants《测定发动机冷却剂中痕量氯离子的试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3634 99 (Reapproved 2005)e1Standard Test Method forTrace Chloride Ion in Engine Coolants1This standard is issued under the fixed designation D 3634; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last re
2、vision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.e1NOTEIn 10.3, the solution was corrected editorially t
3、o AgNo3in June 2006.1. Scope1.1 This test method covers the determination of chlorideion in engine coolants in the range from 5 to 200 ppm in thepresence of up to 0.6 weight % mercaptobenzothiazole.1.2 Other materials that react with silver ion will interfere.1.3 Chloride in engine coolants containi
4、ng an aryltriazoleinstead of mercaptobenzothiazole can be determined directlyby this test method without pretreatment with hydrogen per-oxide.1.4 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.5 This standard does not purport
5、 to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. Specific hazardsstatements are given in Section
6、7.2. Referenced Documents2.1 ASTM Standards:2D 1176 Practice for Sampling and Preparing Aqueous So-lutions of Engine Coolants or Antirusts for Testing Pur-posesD 1193 Specification for Reagent WaterE 200 Practice for Preparation, Standardization, and Stor-age of Standard and Reagent Solutions for Ch
7、emicalAnalysis2.2 Manufacturing Chemists Association Document:3MCA Chemical Safety Data Sheet SD-533. Summary of Test Method3.1 The sample is first treated at a pH of 12 to 13 withaqueous hydrogen peroxide to oxidize the mercaptobenzothia-zole to soluble, noninterfering sulfonate. The treated sample
8、 isdissolved in glacial acetic acid and titrated potentiometricallywith dilute standard silver nitrate solution. Since the solubilityof silver chloride in this system is sufficient to preventobtaining a suitable inflection at the very low limit of the testmethod, some chloride is deliberately added
9、to the glacialacetic acid solvent and then corrected for by a blank titration.4. Significance and Use4.1 This test method permits the determination of very lowlevels of chloride ion in engine coolants containing thecommon corrosion inhibitor, mercaptobenzothiazole, or relatedmercaptans, which would
10、normally interfere with the titrationby also forming insoluble silver salts with silver nitrate.5. Apparatus5.1 Manual Titrations:5.1.1 pH MeterAn expanded scale pH meter which can beread to 1 or 2 mV is desirable but not required. A silver billetindicator electrode4and glass reference electrode5are
11、 used forthe chloride titration. The silver electrode should be polishedoccasionally with fine steel wool or scouring powder andthoroughly rinsed.5.1.2 Buret, 10-mL, micro, Class A, calibrated in 0.02-mLdivisions.1This test method is under the jurisidiction of ASTM Committee D15 on EngineCoolants an
12、d is the direct responsibility of Subcommittee D15.04 on ChemicalProperties.Current edition approved Oct. 1, 2005. Published November 2005. Originallyapproved in 1977. Last previous edition approved in 1999 as D 3634 99e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontac
13、t ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from the Manufacturing Chemists Association, 1825 ConnecticutAve., Washington, DC 20009.4The sole source of supply of the Silver
14、 Billet Electrode known to the committeeat this time is Fisher Scientific (, Catalog No. 13-620-122). If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will receive careful consideration at ameeting of the responsible technical
15、 committee,1which you may attend.5The sole source of supply of the reference electrode known to the committee atthis time is Fisher Scientific (, Catalog No. 13-620-216). If youare aware of alternative suppliers, please provide this information to ASTMInternational Headquarters. Your comments will r
16、eceive careful consideration at ameeting of the responsible technical committee,1which you may attend.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.1.3 Beakers, electrolytic, 250-mL tall form.5.2 Automatic Titrators are satisfact
17、ory for this test method,provided they exhibit resolution and accuracy equivalent tothat specified for manual titrations.5.3 Pipets, 10, 20, and 100-mL, Class A.5.4 Flask, Erlenmeyer, 250 mL, with a 24/40 standard taper,female ground glass joint.5.5 CondenserThe condenser shall be of the water-coole
18、d, reflux, glass-tube type, having a condenser jacketapproximately 200 mm in length. The bottom end of thecondenser shall have a 24/40 male ground glass joint to matchthe Erlenmeyer flask.5.6 Flask, volumetric, 200 mL, Class A.NOTE 1All glassware should be thoroughly cleaned and reserved foruse in t
19、his test method. Great care must be exercised to avoid contami-nation. Glassware should be cleaned with chromic acid (WarningSee7.1.) cleaning solution, then thoroughly rinsed with water, then withacetone (WarningSee 7.2.), and dried.6. Reagents and Materials6.1 Purity of ReagentsReagent grade chemi
20、cals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.6Other grades may beused, provided it is first ascertained
21、 that the reagent is ofsufficiently high purity to permit its use without lessening theaccuracy of the determination.6.2 Purity of WaterReferences to water shall be under-stood to mean Type IV reagent water conforming to Specifi-cation D 1193: total particulate and dissolved matter, 2.0 mg/Lmaximum;
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD363419992005E1STANDARDTESTMETHODFORTRACECHLORIDEIONINENGINECOOLANTS 测定 发动机 冷却剂 痕量 氯离子 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-515141.html