ASTM D3500-1990(2003) Standard Test Methods for Structural Panels in Tension《胶合板承受拉力的标准试验方法》.pdf
《ASTM D3500-1990(2003) Standard Test Methods for Structural Panels in Tension《胶合板承受拉力的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3500-1990(2003) Standard Test Methods for Structural Panels in Tension《胶合板承受拉力的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3500 90 (Reapproved 2003)Standard Test Methods forStructural Panels in Tension1This standard is issued under the fixed designation D 3500; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A
2、number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover the determination of thetens
3、ile properties of structural panels.1.2 Structural panels in use include plywood, waferboard,oriented strand board and composites of veneer, and otherwood-based layers1.3 Test Method A, Tensile Test for Small Specimens:1.3.1 This test method employs small specimens that shouldhave a reduced cross se
4、ction at the center of their length toavoid failure in the grip area. The transition from full width ofspecimen to reduced section at the center should be gradual tominimize stress concentration.1.3.2 When the measurements of elastic properties are to bemade, the length of the reduced cross section
5、at the centershould be of sufficient length to accommodate an extensometer.1.4 Test Method B, Tensile Test for Large Specimens:1.4.1 This test method employs large specimens and re-sponds well to manufacturing variables, plywood growthcharacteristics, and other defects influencing the tensile prop-e
6、rties of structural panels.1.4.2 The test specimens are large enough to contain themaximum sized defects found in plywood panels. The testspecimens have a constant cross section since the size andlocation of defects control the location of failures and the effectof stress concentration at the grips
7、is overshadowed.1.4.3 This test method is recommended for the following:1.4.3.1 Comparative tests of structural panels,1.4.3.2 Determining the influence of any specific strengthreducing defects on the tensile properties of structural panels,1.4.3.3 Determination of tensile properties of plywood andc
8、omposites containing veneer with growth and manufacturingcharacteristics.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine
9、the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:D 2395 Test Methods for Specific Gravity of Wood andWood-Base Materials2D 4442 Test Method for Direct Moisture Content Measure-ment of Wood and Wood-Base Materials23. Significance and Use3.1 These tes
10、t methods determine the tensile properties ofstructural panels in response to stresses acting in the plane ofthe panel.3.2 Test Method AThis test method is suited to materialthat is uniform with respect to tensile properties. It is normallyapplied to structural panels and plywood of clear, straight-
11、grained veneers. It may also be used to evaluate the strength ofscarf and finger joints and other manufacturing process vari-ables that can be expected to influence the tensile properties ofstructural panels in a uniform manner across the width of thesheet.3.3 Test Method BThis test method employs l
12、arge testspecimens and responds well to all manufacturing variablesand growth characteristics that affect the tensile properties ofstructural panels.3.4 It is recommended that where comparisons are to bemade that the same test method and specimen size be usedthroughout. This is because the volume of
13、 material included ina test specimen can influence the tensile strength regardless ofwhether the material properties are uniform throughout thesheet or vary widely due to the presence of growth ormanufacturing features.4. Control of Moisture Content4.1 Structural panel specimens to be tested at spec
14、ificmoisture contents or after reaching equilibrium moisture con-tent at specific temperature and relative humidity conditionsshall be conditioned to approximate constant weight in con-trolled atmospheric conditions. For approximating moistureconditions of structural panels used under dry conditions
15、, arelative humidity of 65 6 2 % at a temperature of (68 6 6F)(20 6 3C) is recommended.1These test methods are under the jurisdiction of ASTM Committee D07 onWood and are the direct responsibility of Subcommittee D07.03 on Panel Products.Current edition approved Oct. 26, 1990. Published December 199
16、0. Originallypublished as D 3500 76. Last previous edition D 3500 76 (1986).2Annual Book of ASTM Standards, Vol 04.10.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5. Variables Influencing Tensile Properties of StructuralPanels5.1
17、Moisture ContentMoisture content shall be deter-mined in accordance with Test Method D 4442.5.2 Specific GravityDetermine specific gravity in accor-dance with Test Methods D 2395. The specimen may be thesame as that for moisture content determination but must havevolume of at least 1 in.3(16 cm3) if
18、 from small specimens (TestMethod A), and at least 3 in.3(49 cm3) if from large specimens(Test Method B). Specimens containing veneer shall be free ofvisible knots or voids in any ply.TEST METHOD ATENSILE PROPERTIESOF SMALL SPECIMENS6. Test Specimens6.1 Specimens may be of Types A, B, or C in Fig. 1
19、.6.1.1 When the evaluation of elastic properties as well asultimate tensile strength is required, the size and shape of thetest specimen shall be selected on the basis of the constructionand thickness of the material. For other structural panels, andplywood or composites with the grain of the indivi
20、dual veneerplies or laminations making grain angles of individual veneerlamina of 0 or 90, Type A shall be used for material over14 in.(6 mm) in thickness and Type B for material14 in. (6 mm) orless in thickness. For plywood with an angle other than 0 or 90between the length of the specimens and the
21、 grain orientation,Type C shall be used regardless of the thickness of the material.The specimens shall have a thickness equal to that of thematerial. The thickness and the width of each specimen at thecritical section shall be measured to an accuracy of not lessthan 60.3 % or 0.001 in. (0.02 mm) wh
22、ichever is larger.6.1.2 The test specimens shall be properly shaped, using atemplate in conjunction with a vertical-spindle wood-work-ingshaper or any other method that will give equally satisfactoryresults.7. Loading Procedure7.1 Hold the specimen in wedge-type self-tightening andself-aligning grip
23、s. Rate of crosshead motion shall be constantthroughout the test such that the specimen breaks within 3 to 10min after initiation of loading. A crosshead motion rate ofU.S. CustomaryUnits, in.Metric EquivalentsmmU.S. CustomaryUnits, in.Metric Equivalentsmm14 6378 9812 13 418 10512514 108178 48 16 40
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD350019902003STANDARDTESTMETHODSFORSTRUCTURALPANELSINTENSION 胶合板 承受 拉力 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-514892.html