ASTM D3474-1990(2007) Standard Practice for Calibration and Use of Torque Meters Used in Packaging Applications《包装用扭矩计校正和使用的标准实施规程》.pdf
《ASTM D3474-1990(2007) Standard Practice for Calibration and Use of Torque Meters Used in Packaging Applications《包装用扭矩计校正和使用的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3474-1990(2007) Standard Practice for Calibration and Use of Torque Meters Used in Packaging Applications《包装用扭矩计校正和使用的标准实施规程》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3474 90 (Reapproved 2007)Standard Practice forCalibration and Use of Torque Meters Used in PackagingApplications1This standard is issued under the fixed designation D 3474; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers the calibration and use of torquemeters of the type normally used in packaging
3、applications.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2.
4、 Referenced Documents2.1 ASTM Standards:2D 3198 Test Method for Application and Removal Torqueof Threaded or Lug-Style Closures3. Terminology3.1 DefinitionsFor definitions of application torque andremoval torque, see Test Method D 3198.3.2 stripping torque a force or system of forces acting ina tigh
5、tening direction that causes overrunning of the threads orrotation of an overshell with respect to its supporting member.4. Summary of Practice4.1 Calibration Reference torque values are obtained bymeans of vertically suspended dead weights acting at specificdistances from the axis of the mounting p
6、latform of the tester.4.2 UseTorque values to apply or remove closures areobtained by mounting containers on the platform and eitherapplying or removing the closures. In some applications, theclosure is mounted on the platform and the container is rotated.5. Significance and Use5.1 This practice can
7、 be used to check devices used tomeasure the application and removal torques of continuous orintermittent thread and lug closures.5.2 This practice can be used to determine the amount oftorque to either apply or remove a closure.6. Apparatus6.1 AdapterA circular plate that can be mounted concen-tric
8、ally on the platform of the tester. If the platform itself issuitable, an adapter is not necessary. The adapter should be ofsuch diameter that its radius multiplied by appropriate weightswill give torque values equal to14 ,12 , and full-scale meterreadings. (Typical devices for packaging application
9、s haveranges from: 0 to 10, 0 to 25, 0 to 50, and 0 to 100 lbf-in. (0to 1.13, 0 to 2.8, 0 to 5.7, and 0 to 11.3 N/m, respectively).6.2 Connecting MeansAvery flexible, thin filament, suchas a wire or fishing line that transmits the force of hangingweights to the circumference of the adapter.6.3 Pulle
10、y, low friction, used to change the direction of theconnecting means from horizontal to vertical.6.4 Appropriate Dead Weights, for example: 2, 4, and 7-lb(0.9, 1.8, and 3.2-kg) for a torque meter with a 7 in. (178 mm)diameter plate or platform and a range of 0 to 25 in-lbs (0 to 2.8N-m).7. Condition
11、ing7.1 Prior to calibration, the torque meter and weights shallbe allowed to come to ambient room conditions.8. Calibration Procedures (see Fig. 1)8.1 Spring-Loaded Type Testers :8.1.1 Verify that the meter needle moves freely throughoutits entire range and rests on zero when not loaded. Adjust ifne
12、cessary.8.1.2 If an adapter is used, fasten it securely and concentri-cally to the tester platform or spindle.8.1.3 Secure the torque meter to a table or work surface.8.1.4 Secure one end of the connecting means to a point onthe circumference of the adapter or rotating platform and wrapit at least h
13、alfway around the circumference.8.1.5 Run the connecting means over a low friction pulleylocated near the edge of a bench or table, and let it hangvertically for the attachment of weights.8.1.6 Sequentially, attach dead weights appropriately to givetorque values equal to14 ,12 , and full-scale meter
14、 readings.Make certain that the weights are hanging freely. Record the1This practice is under the jurisdiction of ASTM Committee D10 on Packagingand is the direct responsibility of Subcommittee D10.31 on Child ResistantPackaging and Closure Systems.Current edition approved Oct. 1, 2007. Published Oc
15、tober 2007. Originallyapproved in 1976. Last previous edition approved in 2002 as D 3474 90 (2002).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Doc
16、ument Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.weight, radius and the meter reading at each test point, makingcertain that the needle returns to zero when the weights areremoved.8.1.7 If the dif
17、ference between the measured and indicatedreadings differ from the manufacturers specification (usually64 % of full scale), the user will need to generate a calibrationchart or have the instrument repaired.8.1.8 For torque meters that measure both clockwise andcounterclockwise, repeat 8.1.6, but wit
18、h the platform rotationin the opposite direction.8.2 Automatic Type Testers:8.2.1 Attach a small flexible string at least halfway aroundthe circumference of the platform and over a low frictionpulley so that calibration weights can be attached.8.2.2 Run the calibration program on the computer.8.2.3
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD347419902007STANDARDPRACTICEFORCALIBRATIONANDUSEOFTORQUEMETERSUSEDINPACKAGINGAPPLICATIONS 包装 扭矩

链接地址:http://www.mydoc123.com/p-514838.html