ASTM D3461-2014 Standard Test Method for Softening Point of Asphalt and Pitch (Mettler Cup-and-Ball Method)《硬沥青软化点的标准试验方法 (米勒杯球法)》.pdf
《ASTM D3461-2014 Standard Test Method for Softening Point of Asphalt and Pitch (Mettler Cup-and-Ball Method)《硬沥青软化点的标准试验方法 (米勒杯球法)》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3461-2014 Standard Test Method for Softening Point of Asphalt and Pitch (Mettler Cup-and-Ball Method)《硬沥青软化点的标准试验方法 (米勒杯球法)》.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3461 97 (Reapproved 2012)D3461 14Standard Test Method forSoftening Point of Asphalt and Pitch (Mettler Cup-and-BallMethod)1This standard is issued under the fixed designation D3461; the number immediately following the designation indicates the year oforiginal adoption or, in the case
2、of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope Scope*1.1 This test method covers the determination of the softening point of asphalt and pitch
3、in the range from 5050 C to180C180 C by the cup-and-ball apparatus, and gives results comparable to those obtained by Test Method D36.NOTE 1If the softening point of asphalt by this Mettler cup-and-ball method fails to meet specified requirements, tests may be rerun using the TestMethod D36 (ring-an
4、d-ball) softening point apparatus as a referee method.NOTE 1If the softening point of asphalt by this Mettler cup-and-ball method fails to meet specified requirements, tests may be rerun using the TestMethod D36 (ring-and-ball) softening point apparatus as a referee method.1.2 This standard does not
5、 purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2
6、A314 Specification for Stainless Steel Billets and Bars for ForgingD36 Test Method for Softening Point of Bitumen (Ring-and-Ball Apparatus)D140 Practice for Sampling Bituminous MaterialsD4296 Practice for Sampling Pitch3. Summary of Test Method3.1 In this test method the softening point is defined a
7、s the temperature at which the specimen, suspended in a cylindrical cupwith a 6.5-mm 6.5 mm hole in the bottom and with a lead ball,8 mm 8 mm in diameter, centered on top of the sample in the cup, flows downward a distance of 19 mm to interrupt a light beam,as the sample is heated at a linear rate i
8、n air.4. Significance and Use4.1 Asphalt and pitch do not go through a solid-liquid phase change when heated, and therefore do not have true melting points.As the temperature is raised, they gradually soften or become less viscous. For this reason, the determination of the softening pointmust be mad
9、e by an arbitrary, but closely defined, method if the test values are to be reproducible.4.2 This test method is useful in determining the consistency as one element in establishing the uniformity of shipments orsources of supply.5. Apparatus5.1 A Mettler METTLER TOLEDO dropping point cell3 can be u
10、sed to determine softening points by this test method. Thesecommercially available instruments consist of a control unit with a digital temperature indicator, matched furnace, indicator with1 This test method is under the jurisdiction of ASTM Committee D02 on Petroleum Products Products, Liquid Fuel
11、s, and Lubricantsand is the direct responsibility ofSubcommittee D02.05 on Properties of Fuels, Petroleum Coke and Carbon Material.Current edition approved Nov. 1, 2012Oct. 1, 2014. Published November 2012November 2014. Originally approved in 1976. Last previous edition approved in 20072012as D3461
12、97 (2007).(2012). DOI: 10.1520/D3461-97R12.10.1520/D3461-14.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.3
13、 Available from the Mettler Toledo, Inc.,The sole source of supply of the apparatus known to the committee at this time is available from Mettler-Toledo, LLC., 1900Polaris Pkwy, Columbus, OH 43240, . If you are aware of alternative suppliers, please provide this information to ASTM International Hea
14、dquarters. Yourcomments will receive careful consideration at a meeting of the responsible technical committee,1 Balances and Instruments, 69 Princeton-Hightstown Rd., Hightstown, NJ08520-0071.which you may attend.This document is not an ASTM standard and is intended only to provide the user of an A
15、STM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as publishe
16、d by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1furnace built in or attached, sample cartridges, and accessories. The
17、 control unit automatically regulates the heating rate of thefurnace. The softening point is indicated on the readout, and the heating program stopped, when the sample flow triggers aphotocell detector. the softening point detection.Ageneral view of the components of the Mettler apparatus METTLER TO
18、LEDOsoftening point instrument is shown in Fig. 1. (old instrument) and Fig. 2 (new instrument).5.1.1 Integrated or Separate Control UnitThis The control unit shall provide a continuous, linear temperature increase from2525 C to 250C250 C at a rate of 2C/min. 2 C/min.Adigital readout shall indicate
19、the temperature to 0.1C 0.1 C throughout.5.1.2 Integrated or Separate Furnace UnitThis The furnace unit shall be capable of heating a specimen cup assembly,one ortwo sample cup assemblies, as described in 5.1.3, at a linear rate of 22 C 6 0.3C/min.0.3 Cmin. It shall include a sensingsystem capable o
20、f detecting the softening point with a precision of 0.1C.0.1 C.5.1.3 SpecimenSample Cup AssemblyAcup of chromium-plated brass, or of aluminum, or of stainless steel conforming to therequirements for Type 303 (UNS 530300) S30300) stainless steel as prescribed in Specification A314, with the dimension
21、s shownin Fig. 23. It shall be placed in the assembly so that the test specimen will flow pitch sample softening point will be detected whenit has flowed down a distance of 19 mm before interrupting a light beam and stopping the heating program as the softening pointis reached.mm.FIG. 1 General View
22、 of the Mettler FP-5/53METTLER TOLEDO FP90 Control Unit with Heater FP83HTD3461 1425.1.4 Lead BallA lead ball weighing 3.20 g 6 0.10 g. A32-caliber A 32-caliber lead shot is suitable for this purpose.FIG. 2 General View of the METTLER TOLEDO DP70FIG. 23 Specimen CupD3461 1436. Reagents6.1 Xylene, in
23、dustrial grade.7. Calibration of Mettler METTLER TOLEDO Apparatus7.1 This step, required only occasionally, is designed to establish that the temperature indicated by the instrument is inagreement with a known standard. A special cup with a bottom orifice of 2.8 mm is used instead of the one prescri
24、bed for thespecimen testing.testing of pitch.7.2 ReagentUse either analytical reagent or primary standard grade benzoic acid for thisthe calibration. As this material ishygroscopic,hygroscopic it must be stored in a tightly sealed container, and replaced with fresh material from a newly openedsupply
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD34612014STANDARDTESTMETHODFORSOFTENINGPOINTOFASPHALTANDPITCHMETTLERCUPANDBALLMETHOD 硬沥青 软化 标准 试验

链接地址:http://www.mydoc123.com/p-514818.html