《ASTM D3138-2004(2016) Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly(Vinyl Chloride) (PVC) Non-Pressure Pip.pdf》由会员分享,可在线阅读,更多相关《ASTM D3138-2004(2016) Standard Specification for Solvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly(Vinyl Chloride) (PVC) Non-Pressure Pip.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D3138 04 (Reapproved 2016)Standard Specification forSolvent Cements for Transition Joints Between Acrylonitrile-Butadiene-Styrene (ABS) and Poly(Vinyl Chloride) (PVC)Non-Pressure Piping Components1This standard is issued under the fixed designation D3138; the number immediately followin
2、g the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved
3、for use by agencies of the U.S. Department of Defense.1. Scope1.1 This specification provides general requirements forsolvent cements used in joining acrylonitrile-butadiene-styrene(ABS) plastic pipe or fittings to poly(vinyl chloride) (PVC)plastic pipe or fittings.1.2 These cements are intended for
4、 use in cementing tran-sition joints between ABS and PVC materials in non-pressureapplications only (25 psi (170 kPa) or less).NOTE 1This specification was developed to provide a means forjoining an ABS non-pressure piping system using a solvent-cementedtransition joint, for example, joining ABS bui
5、lding drain to a PVC sewersystem. The intention was not to create a specification for an all purposeABS-PVC solvent cement that would be used for mixing ofABS and PVCpiping materials nor to specify a cement that could generally be used foreither material. Specific cements for ABS or PVC components s
6、hould beused (see 1.3).1.3 Solvent cements used for joining PVC pipe and fittingsare specified in Specification D2564. Solvent cements used forjoining ABS pipe and fittings are specified in SpecificationD2235.1.4 Arecommended procedure for joiningABS to PVC pipeand fittings for non-pressure applicat
7、ions is given in theappendix.1.5 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.6 The following safety hazards caveat pertains only to
8、 thetest methods portion, Section 6, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of
9、 regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2D1084 Test Methods for Viscosity of AdhesivesD1600 Terminology forAbbreviated Terms Relating to Plas-ticsD1784 Specification for Rigid Poly(Vinyl Chloride) (PVC)Compounds and Chlorinated Poly(Vinyl Chloride)(CPVC) Compo
10、undsD2235 Specification for Solvent Cement for Acrylonitrile-Butadiene-Styrene (ABS) Plastic Pipe and FittingsD2564 Specification for Solvent Cements for Poly(VinylChloride) (PVC) Plastic Piping SystemsD2661 Specification for Acrylonitrile-Butadiene-Styrene(ABS) Schedule 40 Plastic Drain, Waste, and
11、 Vent Pipeand FittingsD2665 Specification for Poly(Vinyl Chloride) (PVC) PlasticDrain, Waste, and Vent Pipe and FittingsF402 Practice for Safe Handling of Solvent Cements,Primers, and Cleaners Used for Joining ThermoplasticPipe and FittingsF412 Terminology Relating to Plastic Piping SystemsF493 Spec
12、ification for Solvent Cements for ChlorinatedPoly(Vinyl Chloride) (CPVC) Plastic Pipe and Fittings3. Terminology3.1 DefinitionsDefinitions are in accordance with Termi-nology F412, and abbreviations are in accordance with Termi-nology D1600, unless otherwise specified.4. Materials and Manufacture4.1
13、 The solvent cement shall be a solution of Class12454-B, unplasticized poly(vinyl chloride) molding or extru-sion compound as classified in Specification D1784, or equiva-lent PVC resin.1This specification is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct res
14、ponsibility of Subcommittee F17.20 on Joining.Current edition approved Nov. 1, 2016. Published November 2016. Originallyapproved in 1972. Last previous edition approved in 2011 as D3138 04(2011).DOI: 10.1520/D3138-04R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
15、ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.2 Either virgin or clean
16、rework material may be used,provided that the rework material is generated from the solventcement manufacturers own production, is compatible withvirgin material, and will produce a cement that meets therequirements of this specification.4.3 The cement shall be free-flowing and shall not containlump
17、s, macroscopic undissolved particles, or any foreignmatter that will adversely affect the ultimate joint strength orchemical resistance of the cement.4.4 The cement shall show no gelation. It shall show nostratification or separation that cannot be removed by stirringor shaking.4.5 Inert fillers may
18、 be added, provided the resulting cementmeets all requirements of this specification.4.6 The solvents used in the formulation of this solventcement shall consist of tetrahydrofuran (THF) in combinationwith cyclohexanone or methyl ethyl ketone (MEK), or both.NOTE 2It is recommended that solvent cemen
19、ts made to this speci-fication not be orange since that color is recommended for use with CPVCsolvent cement under Specification F493.5. Other Requirements5.1 Resin ContentThe PVC resin content shall be 10 %minimum when tested in accordance with 6.1.5.2 DissolutionThe cement shall be capable of diss
20、olvingan additional 3 weight % of Class 12454-B, PVC compound orthe equivalent PVC resin at 73.4 6 3.6F (23 6 2C) withoutevidence of gelation.5.3 ViscosityThe minimum viscosity at room temperatureshall be 90 cP (90 mPas) when tested in accordance with 6.2.NOTE 3Cements approaching the minimum viscos
21、ity requirement ofthis specification generally are not recommended for noninterference-typefit (where a gap exists between the pipe and fitting socket).5.4 Lap Shear StrengthThe minimum average lap shearstrength when tested in accordance with 6.3.2 shall be 600 psi(4.1 MPa) after a 72-h curing time.
22、5.5 Hydrostatic Burst StrengthThe minimum average hy-drostatic burst strength when tested in accordance with 6.3.3shall be 200 psi (1.4 MPa) after a 72-h curing time.6. Test Methods6.1 Solids Content:6.1.1 Apparatus:6.1.1.1 Ointment Tins (Style No. 12, 1-oz (30-mL), allmetal).6.1.1.2 Vacuum Oven.6.1
23、.1.3 Analytical Balance.6.1.1.4 Centrifuge.6.1.2 Procedure:6.1.2.1 Stir the sample thoroughly with a spatula beforeweighing (Note 4). Weight 3.0 6 0.5 g of the sample to thenearest 1 mg into a tared ointment tin. Place the tin into thevacuum oven (Note 5), and heat at 248F (120C) for 45 min+ 15, 0 m
24、in. Discard specimens left in for more than 1 h. Thevacuum must be continually in operation to draw off flammablesolvents. Absolute pressure should not exceed 15 mm Hg.Remove the tin from the oven and place in a desiccator untilcooled to room temperature. Weigh the tin and dried sample tothe nearest
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD313820042016STANDARDSPECIFICATIONFORSOLVENTCEMENTSFORTRANSITIONJOINTSBETWEENACRYLONITRILEBUTADIENESTYRENEABSANDPOLYVINYLCHLORIDEPVCNONPRESSUREPIPPDF

链接地址:http://www.mydoc123.com/p-514136.html