ASTM D3134-1997(2008)e1 Standard Practice for Establishing Color and Gloss Tolerances《颜色和光泽度偏差确定的标准实施规程》.pdf
《ASTM D3134-1997(2008)e1 Standard Practice for Establishing Color and Gloss Tolerances《颜色和光泽度偏差确定的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM D3134-1997(2008)e1 Standard Practice for Establishing Color and Gloss Tolerances《颜色和光泽度偏差确定的标准实施规程》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 3134 97 (Reapproved 2008)1Standard Practice forEstablishing Color and Gloss Tolerances1This standard is issued under the fixed designation D 3134; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTECorrections were made editorially in Footnote 4, 7.2.1, and Section 12 in December 2008.INTRODUCTIONPermissible color and gloss deviat
3、ions from a standard are generally dependent upon the colordiscrimination of the observer, on the lighting and surround in which the material is viewed, and onspecial considerations related to the design, manufacture, and practical usage of the colored materialor object. The tolerances, therefore, m
4、ay be influenced by economic, technical, psychological, andpractical requirements. In many circumstances, acceptability of color and gloss deviations from astandard may differ appreciably from the perceptibility of deviations such as on-tone fadingpreferences, large tolerances for luminance variatio
5、n, nongreen bias, or nonyellow bias. With properallowances, perceptibility data can be used as an aid to develop permissible tolerances. Finally, thesum of all these considerations should result in a specification acceptable to both buyer and seller.1. Scope1.1 This practice describes a procedure fo
6、r establishingtolerances and evaluating the color and gloss of specimens withrespect to specified standards. This practice is appropriate fornonfluorescent opaque specimens.1.2 This practice does not indicate the extent of tolerances,but gives guidance on how they can be set. For productspecificatio
7、n, the tolerances between specimens and the speci-fied standard should be agreed upon between the purchaser andthe seller.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-
8、priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 523 Test Method for Specular GlossD 1535 Practice for Specifying Color by the Munsell Sys-temD 1729 Practice for Visual Appraisal of Colors and Colo
9、rDifferences of Diffusely-Illuminated Opaque MaterialsD 2244 Practice for Calculation of Color Tolerances andColor Differences from Instrumentally Measured ColorCoordinatesD 3964 Practice for Selection of Coating Specimens forAppearance MeasurementsD 4449 Test Method for Visual Evaluation of Gloss D
10、iffer-ences Between Surfaces of Similar AppearanceD 5531 Guide for Preparation, Maintenance, and Distribu-tion of Physical Product Standards for Color and Geomet-ric Appearance of CoatingsE 284 Terminology of AppearanceE 308 Practice for Computing the Colors of Objects byUsing the CIE SystemE 312 Pr
11、actice for Description and Selection of Conditionsfor Photographing Specimens Using Analog (Film) Cam-eras and Digital Still Cameras (DSC)E 805 Practice for Identification of Instrumental Methods ofColor or Color-Difference Measurement of MaterialsE 1164 Practice for Obtaining Spectrometric Data for
12、Object-Color EvaluationE 1331 Test Method for Reflectance Factor and Color bySpectrophotometry Using Hemispherical GeometryE 1345 Practice for Reducing the Effect of Variability ofColor Measurement by Use of Multiple MeasurementsE 1349 Test Method for Reflectance Factor and Color bySpectrophotometry
13、 Using Bidirectional (45:0 or 0:45)GeometryE 1360 Practice for Specifying Color by Using the Optical1This practice is under the jurisdiction of ASTM Committee E12 on Color andAppearance and is the direct responsibility of Subcommittee E12.11 on VisualMethods.Current edition approved Dec. 1, 2008. Pu
14、blished December 2008. Originallyapproved in 1972. Last previous edition approved in 2003 as D 3134 97 (2003).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the st
15、andards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.Society of America Uniform Color Scales SystemE 1499 Guide for Selection, Evaluation, and Training ofObserversE 1541 Practice for Specif
16、ying and Matching Color Usingthe Colorcurve System3E 1708 Practice for Electronic Interchange of Color andAppearance Data2.2 CIE Publication:No. CIE S 014-4/E2007 Colorimetry 2nd ed.43. Terminology3.1 DefinitionsFor definitions of terms related to thispractice see Terminology E 284.4. Summary of Pra
17、ctice4.1 This practice consists of recommendations for the se-lection of a standard, the necessary physical measurements toassess the permanence of the standard to reproduce it whenneeded, and to establish tolerances.4.2 Recommendations are given for the determination of theconformance of a specimen
18、 to preestablished color and glosstolerances by instrumental or visual means.5. Significance and Use5.1 Color specifications are centered around exact positionsin color space. Correspondingly, gloss specifications are cen-tered around an exact position on the gloss scale. Because it isdifficult to a
19、chieve these exact positions repeatedly, it isnecessary to specify tolerances that are acceptable to both thebuyer and the seller. This practice details the procedure foraccomplishing this goal.6. Specimens6.1 The exact method of preparation of the specimen shallbe agreed upon between the purchaser
20、and the seller. However,for the highest precision in instrumental measurements thespecimens should be opaque, uniform in color, plane, anduniform in texture. The specimens should be relatively perma-nent, and capable of being cleaned. Preferred sizes of speci-mens for visual evaluation are given in
21、Practice D 1729, thespecific size being governed by the use of the specimens.7. Procedure7.1 Selection and Specification of Color and Gloss Stan-dard:7.1.1 Select a standard in accordance with Practice D 3964that is preferably the same type of material as the specimens tobe evaluated for color or gl
22、oss, or both. Prepare, in sufficientquantity, secondary standards in accordance with GuideD 5531 that are representative of the desired color and gloss, inthe permanent material. Standards should have the samespectral characteristics as the manufactured product. This isusually accomplished by use of
23、 the same colorant composition,incorporated in the same manner into the same material. Thestandard should have the same texture as the manufacturedproduct.7.1.1.1 In order to obtain a permanent record, use PracticeE 805 and either Test Method E 1331 or Test Method E 1349 tocorrectly identify the ins
24、trumental measurement method. Mea-sure the color in accordance with Practices E 1164 and E 805.Report the color as described in Practice E 308. Do this even ifthe standard is textured. (If the standard is textured, note thetexture orientation during measurement.) The variability of themeasurements d
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD313419972008E1STANDARDPRACTICEFORESTABLISHINGCOLORANDGLOSSTOLERANCES 颜色 光泽 偏差 确定 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-514121.html