ASTM D2712-1991(2010) Standard Test Method for Hydrocarbon Traces in Propylene Concentrates By Gas Chromatography《用气相色谱法测定丙烯浓缩物中烃类痕量的标准试验方法》.pdf
《ASTM D2712-1991(2010) Standard Test Method for Hydrocarbon Traces in Propylene Concentrates By Gas Chromatography《用气相色谱法测定丙烯浓缩物中烃类痕量的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2712-1991(2010) Standard Test Method for Hydrocarbon Traces in Propylene Concentrates By Gas Chromatography《用气相色谱法测定丙烯浓缩物中烃类痕量的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2712 91 (Reapproved 2010)Standard Test Method forHydrocarbon Traces in Propylene Concentrates by GasChromatography1This standard is issued under the fixed designation D2712; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revis
2、ion, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of 5 to 500ppm each of ethylene, total butylenes, acetylene
3、, methylacetylene, propadiene, and butadiene in propylene concen-trates.1.2 The values stated in SI units are to be regarded asstandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. I
4、t is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2E260 Practice for Packed Column Gas ChromatographyF307 Practice for Sampling Pr
5、essurized Gas for Gas Analy-sis3. Summary of Test Method3.1 A relatively large volume of sample is charged to a gaspartition chromatography apparatus which has a column thatwill separate the trace hydrocarbon constituents from the majorcomponents. Any column or combination of columns may beused prov
6、ided they have the necessary resolution and thedetecting system has sufficient sensitivity. Several columns thathave been found satisfactory are given in 5.1.3.2 Calculation is performed by calculating the concentra-tion of the trace compound from its area relative to the area ofa standard compound
7、of known concentration.4. Significance and Use4.1 The trace hydrocarbon compounds listed in Table 1 mayhave an effect in the commercial use of propylene concentrates,and information on their concentration is frequently necessary.5. Apparatus5.1 ColumnsAny column may be used provided it willresolve t
8、he trace compound peaks present in concentrations of20 ppm or more so that the resolution ratio, A/B, will not beless than 0.4, where A is the depth of the valley on either sideof peak B and B is the height above the baseline of the smallerof any two adjacent peaks (see Fig. 1). For compounds presen
9、tin concentrations of less than 20 ppm the ratio A/B may be lessthan 0.4. In the case where the small-component peak isadjacent to a large one, it may be necessary to construct thebaseline of the small peak tangent to the curve as shown in Fig.2. Butylenes need not be resolved from each other. Colum
10、nsfound to be acceptable together with operating conditions usedare shown in Table 2. Table 3 shows typical retention times.5.1.1 Columns may be constructed of 3.2 -mm (18-in.), 6.4-mm (14-in.), or capillary tubing and usually need to be aminimum of 6 m (20 ft) in length. They usually have 20 to 40g
11、 of liquid substrate to 100 g of solid support. If packedcolumns are used, the liquid may be placed on the solid supportby any suitable method, provided the column has the desiredresolution and sensitivity.NOTE 1Separation of all the desired compounds on a single columnhas been found by cooperators
12、to be very difficult. Most laboratories havefound it necessary to use two or more columns. Typical instructions forpreparing such columns may be found in Practice E260.5.2 Gas ChromatographAny gas chromatography appa-ratus may be used provided the system has sufficient sensitivityto detect the trace
13、 compounds of interest. For calculationtechniques utilizing a recorder, the signal for 20 ppm concen-tration shall be at least 5 chart divisions above the noise levelona0to100scale chart. The noise level must be restricted toa maximum of 2 chart divisions. When electronic integration isemployed, the
14、 signal for 20-ppm concentration must be at leasttwice the noise level.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.D0.03 on Propylene.Current edition approved May 1, 2010. Published May 2010
15、. Originallyapproved in 1968. Last previous edition approved in 2003 as D2712 91 (2003)E1.DOI: 10.1520/D2712-91R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to t
16、he standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.NOTE 2A flame ionization detector is preferred. When using withrelatively volatile liquid phases, such as HMPA, an additional 0.31-
17、m(1-ft) section of column containing uncoated solid support will aid inreducing noise.5.3 Sample IntroductionMeans shall be provided for in-troducing a measured quantity of sample into the apparatus.Pressure sampling devices may be used to inject a smallamount of the liquid directly into the carrier
18、 gas. Introductionmay be by means of a gas valve to charge the vaporized liquid.6. Reagents and Materials6.1 Hydrocarbons, for peak identification, including propy-lene, ethylene, ethane, acetylene, methyl acetylene, propadi-ene, propane, 1,3-butadiene, isobutylene, 1-butene, cis andtrans 2-butene,
19、iso- and normal butane, and cyclopropane.(WarningLiquefied petroleum gas under pressure and flam-mable.) Mixtures of these hydrocarbons may be used forcalibration provided there is no uncertainty as to the identity ofthe desired compound.6.2 Propane or Propylene, for synthetic base stock contain-ing
20、 less than 2 ppm by weight of acetylene or 1,3-butadiene.(WarningLiquefied petroleum gas under pressure and flam-mable.)6.3 Calibration CompoundsAcetylene and 1,3-butadiene99 % minimum purity. (WarningLiquefied petroleum gasunder pressure and flammable.)6.4 Carrier GasesHelium or Nitrogen.(WarningCo
21、mpressed gas under pressure.)6.5 Hydrogen.(WarningCompressed gas under pressureand flammable.)6.6 Liquid Phase for ColumnSee Table 2.(WarningHexamethylphosphoramide is a potential carcinogen.)6.7 Solid SupportC22firebrick or diatomaceous earth,usually 40 to 60 or 60 to 80 mesh.6.8 Stainless Steel Sa
22、mple Cylinder, 300 to 500-cm3capac-ity, capable of withstanding a minimum of 1723 kPa gage (250psig).6.9 Silicone Rubber Septum, with suitable fittings for attach-ment to sample cylinder.6.10 Gas Syringe, 10-cm3.6.11 Vacuum Pump, capable of evacuating sample cylinderto less than 2 mm Hg absolute pre
23、ssure.6.12 Aluminum or Stainless Steel Tubing, 0.61 m (2 ft), 3.2mm (18 in.), or 1.6 mm (116 in.), outside diameter with fittingson one end to connect to butadiene cylinder and the other endmodified so as to have an opening with an inside diameter ofabout 0.5 mm larger than the outside diameter of t
24、he gassyringe needle.7. Sampling7.1 This section is to be followed on all samples includingunknown samples and the synthetic standards.7.2 Samples should be supplied to the laboratory in high-pressure sample cylinders, obtained using the proceduresdescribed in Practice F307 or similar methods.7.3 Pl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD271219912010STANDARDTESTMETHODFORHYDROCARBONTRACESINPROPYLENECONCENTRATESBYGASCHROMATOGRAPHY 用气相

链接地址:http://www.mydoc123.com/p-513391.html