ASTM D2603-2001(2013) Standard Test Method for Sonic Shear Stability of Polymer-Containing Oils《含油聚合物声波切变稳定性的标准试验方法》.pdf
《ASTM D2603-2001(2013) Standard Test Method for Sonic Shear Stability of Polymer-Containing Oils《含油聚合物声波切变稳定性的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2603-2001(2013) Standard Test Method for Sonic Shear Stability of Polymer-Containing Oils《含油聚合物声波切变稳定性的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2603 01 (Reapproved 2013)Standard Test Method forSonic Shear Stability of Polymer-Containing Oils1This standard is issued under the fixed designation D2603; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the evaluatio
3、n of the shearstability of an oil containing polymer in terms of the permanentloss in viscosity that results from irradiating a sample of the oilin a sonic oscillator. This test method can be useful inpredicting the continuity of this property in an oil where nochange is made in the base stock or th
4、e polymer. It is notintended that this test method serve to predict the performanceof polymer-containing oils in service.1.2 Evidence has been presented that correlation betweenthe shear degradation results obtained by means of sonicoscillation and those obtained in mechanical devices can bepoor. Th
5、is is especially true in the case of automotive engines.Further evidence indicates that the sonic technique may ratedifferent families of polymers in a different order than me-chanical devices.2,31.3 Because of these limitations, the committee underwhose jurisdiction this test method falls has devel
6、oped analternative shear test method using a diesel injector nozzle, TestMethod D3945. While that test method has found some utilityin the evaluation of crankcase oils, the stress imparted to thesample has been found to be insufficient to shear polymers ofthe shear-resistant type found in aircraft h
7、ydraulic fluids.1.4 This test method is used for polymeric additivespecifications, especially in the hydraulic fluid market.1.5 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are provided forinformational purposes only.1.6 This standard does not purp
8、ort to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:4D44
9、5 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and Calculation of Dynamic Viscos-ity)D3945 Test Method for Sheer Stability of Ploymer-Containing Fluids Using a Diesel Injector Nozzle (With-drawn 1998)5D6022 Practice for Calculation of Permanent Shear StabilityIndex3. Summary
10、 of Test Method3.1 A convenient volume of polymer-containing oil is irra-diated in a sonic oscillator for a period of time and the changesin viscosity are determined by Test Method D445. Standardreference fluids containing either a readily sheared or shear-resistant polymer are run frequently to ens
11、ure that the equip-ment imparts a controlled amount of sonic energy to thesample.NOTE 1The conditions to obtain the data for the precision statementwere a 30mL sample, 10 min, and at 0C.4. Significance and Use4.1 This test method permits the evaluation of shear stabilitywith minimum interference fro
12、m thermal and oxidative factorswhich may be present in some applications. Within thelimitations expressed in the scope of this test method, it hasbeen successfully applied to hydraulic fluids, transmissionfluids, tractor fluids, and other fluids of similar applications. Ithas been found applicable t
13、o fluids containing both readilysheared and shear-resistant polymers. Correlation with perfor-mance in the case of automotive engine applications has, todate, not been established.1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricantsand is the direct r
14、esponsibility of SubcommitteeD02.07 on High Temperature Rheology of Non-Newtonian Fluids.Current edition approved May 1, 2013. Published August 2013. Originallyapproved in 1967. Last previous edition approved in 2007 as D2603 01 (2007).DOI: 10.1520/D2603-01R13.2The Effects of Polymer Degradation on
15、Flow Properties of Fluids andLubricants, ASTM STP 382,ASTM, 1965.Available fromASTM Headquarters, 100Barr Harbor Drive, West Conshohocken, PA 19428, www.astm.org.3Shear Stability of Multigrade Crankcase Oil, ASTM DS 49, ASTM, 1973.Available from ASTM Headquarters, 100 Barr Harbor Drive, West Conshoh
16、ocken,PA 19428, www.astm.org.4For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.5The last approved version of th
17、is historical standard is referenced onwww.astm.org.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15. Apparatus5.1 Sonic Shear Unit, fixed frequency oscillator and sonichorn.5.2 Auxiliary EquipmentTo facilitate uniformperformance, th
18、e following auxiliary equipment is recom-mended:5.2.1 Cooling Bath or Ice BathTo maintain a desiredtemperature such as 0C.5.2.2 Griffn 50 mL Beaker, borosilicate glass.5.2.3 Sonic-Insulated BoxTo enclose the sonic horn toreduce the ambient noise level produced by the sonic shearunit.5.3 ViscometerAn
19、y viscometer and bath meeting the re-quirements of Test Method D445.6. Reference Fluids6.1 The primary reference fluid is ASTM Reference FluidA,6a petroleum oil containing a polymer capable of beingbroken down by turbulence at high rates of shear. This oil hasthe following typical properties:Petrole
20、umBaseReferenceFluid AViscosity at 100C, mm2/s (cSt) 5.4 10.8Viscosity at 40C, mm2/s (cSt) 32 586.2 A second reference fluid is ASTM Reference Fluid B,6a petroleum oil containing a polymer capable of being brokendown by turbulence at high rates of shear. This oil has aviscosity of about 13.6 mm2/s (
21、cSt) at 40C.7. Calibration of Apparatus7.1 The reference fluid provides a practical way to definethe performance (severity level) of a sonic oscillator unit sothat satisfactory comparison can be made between tests run ondifferent days in the same unit and between tests run withdifferent units.7.2 Th
22、e decrease in viscosity observed for a given polymer-containing oil on irradiation in an oscillator unit depends on anumber of factors; these include sample volume, irradiationtime, and oscillator power setting. These parameters can bevaried in order to increase or decrease severity of test exposure
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD260320012013STANDARDTESTMETHODFORSONICSHEARSTABILITYOFPOLYMERCONTAININGOILS 含油 聚合物 声波 切变 稳定性 标准

链接地址:http://www.mydoc123.com/p-513157.html