ASTM D2505-1988(2010) Standard Test Method for Ethylene Other Hydrocarbons and Carbon Dioxide in High-Purity Ethylene by Gas Chromatography《气相色谱法测定高纯度乙烯中乙烯、其它烃类和二氧化碳的标准试验方法》.pdf
《ASTM D2505-1988(2010) Standard Test Method for Ethylene Other Hydrocarbons and Carbon Dioxide in High-Purity Ethylene by Gas Chromatography《气相色谱法测定高纯度乙烯中乙烯、其它烃类和二氧化碳的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D2505-1988(2010) Standard Test Method for Ethylene Other Hydrocarbons and Carbon Dioxide in High-Purity Ethylene by Gas Chromatography《气相色谱法测定高纯度乙烯中乙烯、其它烃类和二氧化碳的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D2505 88 (Reapproved 2010)Standard Test Method forEthylene, Other Hydrocarbons, and Carbon Dioxide in High-Purity Ethylene by Gas Chromatography1This standard is issued under the fixed designation D2505; the number immediately following the designation indicates the year oforiginal adop
2、tion or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of carbondioxide, methane, eth
3、ane, acetylene, and other hydrocarbons inhigh-purity ethylene. Hydrogen, nitrogen, oxygen, and carbonmonoxide are determined in accordance with Test MethodD2504. The percent ethylene is obtained by subtracting thesum of the percentages of the hydrocarbon and nonhydrocar-bon impurities from 100. The
4、method is applicable over therange of impurities from 1 to 500 parts per million volume(ppmV).1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health pra
5、ctices and determine the applica-bility of regulatory limitations prior to use. For some specifichazard statements, see Section 6.1.3 The values stated in acceptable metric units are to beregarded as the standard. The values in parentheses are forinformation only.2. Referenced Documents2.1 ASTM Stan
6、dards:2D2504 Test Method for Noncondensable Gases in C2andLighter Hydrocarbon Products by Gas ChromatographyD4051 Practice for Preparation of Low-Pressure GasBlendsE260 Practice for Packed Column Gas ChromatographyF307 Practice for Sampling Pressurized Gas for Gas Analy-sis3. Summary of Test Method3
7、.1 The sample is separated in a gas chromatograph systemutilizing four different packed chromatographic columns withhelium as the carrier gas. Methane and ethane are determinedby using a silica gel column. Propylene and heavier hydrocar-bons are determined using a hexamethylphosphoramide(HMPA) colum
8、n. Acetylene is determined by using, in series,a hexadecane column and a squalane column. Carbon dioxideis determined using a column packed with activated charcoalimpregnated with a solution of silver nitrate in b,b8-oxydipropionitrile. Columns other than those mentioned abovemay be satisfactory (se
9、e 5.3). Calibration data are obtainedusing standard samples containing the impurities, carbondioxide, methane, and ethane in the range expected to beencountered. Calibration data for acetylene are obtained as-suming that acetylene has the same peak area response on aweight basis as methane. The acet
10、ylene content in a sample iscalculated on the basis of the ratio of peak area of the acetylenepeak to the peak area of a known amount of methane.Calculations for carbon dioxide, methane, and ethane arecarried out by the peak-height measurement method.4. Significance and Use4.1 High-purity ethylene i
11、s required as a feedstock for somemanufacturing processes, and the presence of trace amounts ofcarbon dioxide and some hydrocarbons can have deleteriouseffects. This method is suitable for setting specifications, foruse as an internal quality control tool and for use in develop-ment or research work
12、.5. Apparatus5.1 Any chromatographic instrument with an overall sensi-tivity sufficient to detect 2 ppmV or less of the compoundslisted with a peak height of at least 2 mm without loss ofresolution.5.2 DetectorsThermal ConductivityIf a methanation re-actor is used, a flame ionization detector is als
13、o required. Todetermine carbon dioxide with a flame ionization detector, amethanation reactor must be inserted between the column and1This test method is under the jurisdiction of ASTM Committee D02 onPetroleum Products and Lubricants and is the direct responsibility of SubcommitteeD02.D0.02 on Ethy
14、lene.Current edition approved May 1, 2010. Published May 2010. Originallyapproved in 1966. Last previous edition approved in 2004 as D2505 88 (2004)E1.DOI: 10.1520/D2505-88R10.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. Fo
15、r Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.the detector and hydrogen added as a reduction gas (see TestMethod D25
16、04, Appendix X1, Preparation of MethanationReactor).5.3 ColumnAny column or set of columns can be usedthat separates carbon dioxide, methane, acetylene and C3andheavier compounds. There may be tailing of the ethylene peakbut do not use any condition such that the depth of the valleysahead of the tra
17、ce peak is less than 50 % of the trace peakheight. (See Fig. 1 for example.)5.4 RecorderA recorder with a full-scale response of 2 sor less and a maximum rate of noise of 60.3 % of full scale.5.5 Gas-Blending ApparatusA typical gas-blending appa-ratus is shown in Fig. 2. A high-pressure manifold equ
18、ippedwith a gage capable of accurately measuring ethylene pressuresup to 3.4 MN/m2gage (500 psig) is required. Other types ofgas-blending equipment, such as described in Practice D4051,can be used.NOTE 1 Practice E260 contains information that will be helpful tothose using this method.6. Reagents an
19、d Materials6.1 Copper or Aluminum, or Stainless Steel Tubing, 6.4-mm(14-in. ) outside diameter, and nylon tubing, 3.2-mm (18-in.)outside diameter.6.2 Solid SupportsCrushed firebrick or calcined diatoma-ceous earth, such as Chromosorb P,335 to 80-mesh and 80 to100-mesh. Other supporting materials or
20、mesh sieves can besatisfactory.6.3 Active SolidsActivated carbon, 30 to 40-mesh,4silicagel, 100 to 200-mesh.5Other sizes may be satisfactory.6.4 Liquid PhasesHexamethylphosphoramide (HMPA6),hexadecane.6Squalene,6silver nitrate, and b,b8-oxydipropionitrile.7Other liquid phases may be satisfactory.(Wa
21、rningCombustible solvents. See A1.7.) (WarningHMPAmay be harmful if inhaled. Causes irritation.Apotentialcarcinogen (lungs). See A1.5.)6.5 Helium.(WarningCompressed Gas, Hazardous Pres-sure. See A1.2.)6.6 Hydrogen.(WarningFlammable Gas, HazardousPressure. See A1.6.)6.7 Acetone.(WarningExtremely Flam
22、mable. See A1.1.)6.8 Gases for CalibrationPure or research grade carbondioxide, methane, ethane, acetylene, ethylene, propane, andpropylene. Certified calibration blends are commercially avail-able from numerous sources and may be used. (WarningFlammable Gases, Hazardous Pressure. See A1.2 and A1.3.
23、)6.9 Methanol.(WarningFlammable. Vapor Harmful. SeeA1.4.)3The sole source of supply of the apparatus is available from the Celite Division,Johns Mansville Co., New York, NY. If you are aware of alternative suppliers,please provide this information to ASTM International Headquarters. Your com-ments w
24、ill receive careful consideration at a meeting of the responsible technicalcommittee1, which you may attend.4A fraction sieved in the laboratory to 30 to 40 mesh from medium activitycharcoal, 20 to 60 mesh, sold by Central Scientific Co., 1700 Irving Park Road,Chicago, IL 60613, has been found satis
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD250519882010STANDARDTESTMETHODFORETHYLENEOTHERHYDROCARBONSANDCARBONDIOXIDEINHIGHPURITYETHYLENEBYGASCHROMATOGRAPHY

链接地址:http://www.mydoc123.com/p-512988.html