1、Designation: D955 08 (Reapproved 2014)Standard Test Method ofMeasuring Shrinkage from Mold Dimensions ofThermoplastics1This standard is issued under the fixed designation D955; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the ye
2、ar of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test method is intend
3、ed to measure shrinkage frommold cavity to molded dimensions of thermoplastics whenmolded by compression or injection processes with specifiedprocess conditions.1.2 This test method covers shrinkage measurements at 24and 48 hours.1.3 This method will give comparable data based on stan-dard specimens
4、 and can not predict absolute values in actualmolded parts with varying flow paths, wall thicknesses, pres-sure and temperature gradients and process conditions. Differ-ences in mold shrinkage may also be observed among the threespecimen geometries described in this test method.1.4 The values stated
5、 in SI units are to be regarded as thestandard. The values given in parentheses are given forinformation only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safet
6、y and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1This standard and ISO 294-3 are equivalent in the design ofspecimen D2. This test method is equivalent to ISO 294-4 where Type D2specimens and the procedure in Appendix X2 are used.2. Referenced Docu
7、ments2.1 ASTM Standards:2D618 Practice for Conditioning Plastics for TestingD788 Classification System for Poly(Methyl Methacrylate)(PMMA) Molding and Extrusion CompoundsD883 Terminology Relating to PlasticsD3641 Practice for Injection Molding Test Specimens ofThermoplastic Molding and Extrusion Mat
8、erialsD4066 Classification System for Nylon Injection and Extru-sion Materials (PA)D4549 Classification System and Basis for Specification forPolystyrene and Rubber-Modified Polystyrene Moldingand Extrusion Materials (PS)D4703 Practice for Compression Molding ThermoplasticMaterials into Test Specime
9、ns, Plaques, or SheetsD4976 Specification for Polyethylene Plastics Molding andExtrusion MaterialsD5947 Test Methods for Physical Dimensions of SolidPlastics SpecimensD6778 Classification System and Basis for Specification forPolyoxymethylene Molding and Extrusion Materials(POM)D6779 Classification
10、System for and Basis of Specificationfor Polyamide Molding and Extrusion Materials (PA)E691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method2.2 ISO Standards:3ISO 293 PlasticsCompression Moulding Test Specimensof Thermoplastic MaterialsISO 294-1 PlasticsInj
11、ection Moulding of Test Specimensof Thermoplastic MaterialsPart 1: General Principles,and Moulding of Multipurpose and Bar Test specimensISO 294-3 PlasticsInjection Moulding of Test Specimensof Thermoplastic MaterialsPart 3: Small PlatesISO 294-4 PlasticsInjection Moulding of TestSpecimensPart 4: De
12、termination of Moulding Shrink-age3. Terminology3.1 DefinitionsGeneral definitions of terms applying tothis test method appear in Terminology D883.3.2 Definitions of Terms Specific to This Standard:1This test method is under the jurisdiction ofASTM Committee D20 on Plasticsand is the direct responsi
13、bility of Subcommittee D20.09 on Specimen Preparation.Current edition approved Aug. 1, 2014. Published August 2014. Originallyapproved in 1948. Last previous edition approved in 2008 as D955 - 08. DOI:10.1520/D0955-08R14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
14、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from American National Standards Institute (ANSI), 25 W. 43rd St.,4th Floor, New York, NY 10036, http:/www.ansi.org.Copyright AST
15、M International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.1 jetting, nnon-uniform multi-directional flow frontapparent on the surface of the mold due to rapid filling of themold cavity.4. Summary of Test Method4.1 The principle of this test method is to
16、 compare moldcavity dimensions with specimen dimensions and report thedifferences in percent.5. Significance and Use5.1 Injection MoldingIn injection molding, the differencebetween the dimensions of a mold cavity and of the moldedspecimen may vary according to the design of the mold andoperation of
17、the molding process. Factors such as mold andmelt temperature, fill times, and packing conditions are knownto affect shrinkage significantly. Adherence to the specifiedmold design (see 7.1) and specifications outlined in PracticeD3641 or ISO 294-4 or the appropriate material specificationwill improv
18、e the reproducibility of the test.5.2 Compression MoldingIn compression molding, thedifference between the dimensions of a mold cavity and of themolded specimen may vary according to the design of the moldand operation of the molding process. Factors, such as theamount of material in charge, cooling
19、 time, and pressureapplication are known to affect shrinkage significantly. Adher-ence to the specified mold design (see 7.2) and specificationsoutlined in Practice D4703 or ISO 293 or the appropriatematerial specifications will improve the reproducibility of thetest.6. Sample Preparation6.1 Some ma
20、terials require special treatment before they aremolded. For example, thermoplastics, which absorb moisturemust be dried before molding. For required conditions forsample preparation, refer to the appropriate material specifica-tion or the manufacturers recommendations if no specificationis availabl
21、e. The preparation given to the material prior tomolding shall be recorded and reported.7. Apparatus7.1 Injection MoldSpecimens shall be molded in a twocavity mold conforming with dimensions as shown in Figs. 1and 2 for the 60 60-mm plaque specimen (Type D2), Fig. 3for the 12.7 by 127-mm bar specime
22、n (Type A) and Fig. 4 forthe 100 mm by 3.2-mm disk specimen (Type B). Pressuretransducers for monitoring the pressure in at least one cavityare mandatory for Type D2. Mold shrinkage measurementsshall be made on specimens that have been molded at one ofthe following cavity pressures 6 3 % from the se
23、lectedpressure: 20 MPa, 40 MPa, 60 MPa, 80 MPa, 100 MPa, or asspecified in the appropriate material specification. Pressuretransducers are recommended, but not mandatory for speci-mens Type A and Type B.7.2 Compression MoldA single cavity positive mold hav-ing cavity dimensions conforming to the dim
24、ensions of Fig. 2for the 60 60-mm plaque (Type D2) Fig. 3 for the 12.7 127-mm bar specimen (Type A) and Fig. 4 for the 100-mm 3.2-mm disk specimen (Type B), not including the sprue,runner or gate.Sp | sprueG | gateLc= distance between the lines along which the test specimens are cut from the runners
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD95520082014STANDARDTESTMETHODOFMEASURINGSHRINKAGEFROMMOLDDIMENSIONSOFTHERMOPLASTICS 测量 塑性 塑料 模型

链接地址:http://www.mydoc123.com/p-512587.html