1、Designation: D 955 00Standard Test Method ofMeasuring Shrinkage from Mold Dimensions ofThermoplastics1This standard is issued under the fixed designation D 955; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revis
2、ion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope *1.1 This test method is intended to measure shrinkage frommold cavity to molded dimensions of thermoplastics whenmolded by compre
3、ssion or injection processes with specifiedprocess conditions.1.2 This test method covers initial shrinkage measurements.The method also accommodates shrinkage at 24 and 48 h,which may be critical for some materials.1.3 This method will give comparable data based on stan-dard specimens and can not p
4、redict absolute values in actualmolded parts with varying flow paths, wall thicknesses, pres-sure gradients and process conditions. Differences in moldshrinkage may also be observed between the three specimengeometries described in this test method.1.4 The values stated in SI units are to be regarde
5、d as thestandard. The values given in parentheses are given forinformation only.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and det
6、ermine the applica-bility of regulatory limitations prior to use.NOTE 1This test method is technically identical to ISO 294-4 whereType D2 specimens are used except that pressure transducers are an optionin this test method and required in ISO 294-4.2. Referenced Documents2.1 ASTM Standards:D 374 Te
7、st Methods for Thickness of Solid Electrical Insu-lation2D 618 Practice for Conditioning Plastics and ElectricalInsulating Materials for Testing3D 788 Classification System for Poly(Methyl Methacrylate)(PMMA) Molding and Extension Compounds3D 883 Terminology Relating to Plastics3D 3641 Practice for
8、Injection Molding of Test Specimens ofThermoplastic Molding and Extrusion Materials4D 4066 Specification for Nylon Injection and ExtrusionMaterials4D 4181 Specification for Acetal (POM) Molding and Extru-sion Materials4D 4549 Specification for Polystyrene Molding and Extru-sion Materials (PS)5D 4703
9、 Practice for Compression Molding of Thermoplas-tic Materials into Test Specimens, Plaques, Sheets5D 4976 Specification for Polyethylene Plastics Molding andExtension Materials5D 5947 Test Methods for Physical Dimensions of SolidPlastics Specimens5E 691 Practice for Conducting an Interlaboratory Stu
10、dy toDetermine the Precision of a Test Method62.2 ISO Standards:ISO 293 PlasticsCompression Moulding Test Specimensof Thermoplastic Materials7ISO 294-3 PlasticsInjection Moulding of Test Specimensof Thermoplastic MaterialsPart 3: Small Plates7ISO 294-4 PlasticsInjection Moulding of TestSpecimensPart
11、 4: Determination of Moulding Shrink-age73. Terminology3.1 DefinitionsGeneral definitions of terms applying tothis test method appear in Terminology D 883.3.2 Definitions of Terms Specific to This Standard:3.2.1 demolding, nremoving the specimens from themold.1This test method is under the jurisdict
12、ion of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.09 on Specimen Preparation.Current edition approved Nov. 10, 2000. Published January 2001. Originallypublished as D 955 48T. Last previous edition D 955 89 (1996).2Annual Book of ASTM Standards, Vol 10.01.3Annu
13、al Book of ASTM Standards, Vol 08.01.4Annual Book of ASTM Standards, Vol 08.02.5Annual Book of ASTM Standards, Vol 08.03.6Annual Book of ASTM Standards, Vol 14.02.7Available from American National Standards Institute, 11 W. 42nd St., 13thFloor, New York, NY 10036.1*A Summary of Changes section appea
14、rs at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.4. Summary of Test Method4.1 The principle of this test method is to compare moldcavity dimensions with specimen dimensions and report thedifferences in pe
15、rcent.5. Significance and Use5.1 Injection MoldingIn injection molding, the differencebetween the dimensions of a mold cavity and of the moldedspecimen may vary according to the design of the mold andoperation of the molding process. Factors such as mold andmelt temperature, fill times, and packing
16、conditions are knownto affect shrinkage significantly. Adherence to the specifiedmold design (see 7.1) and specifications outlined in PracticeD 3641 or ISO 294-4 or the appropriate material will improvethe reproducibility of the test.5.2 Compression MoldingIn compression molding, thedifference betwe
17、en the dimensions of a mold cavity and of themolded specimen may vary according to the design of the moldand operation of the molding process. Factors, such as theamount of material in charge, cooling time, and pressureapplication are known to affect shrinkage significantly. Adher-ence to the specif
18、ied mold design (see 7.2) and specificationsoutlined in Practice D 4703 or ISO 293 or the appropriatematerial specifications will improve the reproducibility of thetest.6. Sample Preparation6.1 Some materials require special treatment before they aremolded. For example, thermoplastics, which absorb
19、moisturemust be dried before molding. Refer to the manufacturersrecommendations for required conditions or appropriate mate-rial specification. The preparation given to the material prior tomolding shall be recorded and reported.7. Apparatus7.1 Injection MoldSpecimens shall be molded in a twocavity
20、mold conforming with dimensions as shown in Figs. 1and 2 for the 60 3 60-mm plaque specimen (Type D2), Fig. 3for the 12.7 3 127-mm bar specimen (Type A) and Fig. 4 forthe 100mm 3 3.2-mm disk specimen (Type B). The mold mayhave scribe marks included for the measurement of shrinkage.The scribe marks s
21、hall be 1.0 mm long by .01 mm wide located1.0 mm from each edge on one side of the mold. Pressuretransducers for monitoring the pressure in at least one cavityare mandatory for Type D2. Mold shrinkage measurementsshould be made on specimens that have been molded at one ofthe following cavity pressur
22、es 6 3 % from the selectedpressure: 20 MPa, 40 MPa, 60 MPa, 80 MPa, 100 MPa, or asspecified in the appropriate material specification. Pressuretransducers are recommended, but not mandatory for speci-mens Type A and Type B.7.2 Compression MoldA single cavity positive mold hav-ing cavity dimensions c
23、onforming to the dimensions of Fig. 2for the 60 3 60-mm plaque (Type D2) Fig. 3 for the 12.7 3127-mm bar specimen (Type A) and Fig. 4 for the 100-mm 33.2-mm disk specimen (Type B), not including the sprue,runner or gate. The mold may have scribe marks included forthe measurement of shrinkage. The sc
24、ribe marks shall be 1.0mm long by 0.1 mm wide located 1.0 mm from each edge onone side of the mold.7.3 Injection PressA suitable injection molding machinethat will fill the test molds when it is operated in the range from20 to 80 % of its rated shot capacity at the molding parametersSp sprue molding
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD9552000STANDARDTESTMETHODOFMEASURINGSHRINKAGEFROMMOLDDIMENSIONSOFTHERMOPLASTICS 塑料 模型 尺寸 收缩 测量 标准

链接地址:http://www.mydoc123.com/p-512585.html