ASTM D877-2002(2007) Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes《用圆盘电极测定绝缘液体介电击穿电压的标准试验方法》.pdf
《ASTM D877-2002(2007) Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes《用圆盘电极测定绝缘液体介电击穿电压的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D877-2002(2007) Standard Test Method for Dielectric Breakdown Voltage of Insulating Liquids Using Disk Electrodes《用圆盘电极测定绝缘液体介电击穿电压的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 877 02 (Reapproved 2007)Standard Test Method forDielectric Breakdown Voltage of Insulating Liquids UsingDisk Electrodes1This standard is issued under the fixed designation D 877; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test met
3、hod describes two procedures, A and B, fordetermining the electrical breakdown voltage of insulatingliquid specimens. The breakdown test uses ac voltage in thepower-frequency range from 45 to 65 Hz.1.2 This test method is used to judge if the disk electrodebreakdown voltage requirements are met for
4、insulating liquids,as delivered from the manufacturer, that have never beenfiltered or dried. See Specification D 3487, SpecificationD 4652, and Guide D 5222 for the minimum specified electri-cal breakdown. This test method should be used as recom-mended by professional organization standards such a
5、s IEEEC57.106.1.3 Limitations of the Procedures:1.3.1 The sensitivity of this test method to the generalpopulation of contaminants present in a liquid sample de-creases as applied test voltages used in this test method becomegreater than approximately 25 kV rms.1.3.2 If the concentration of water in
6、 the sample at roomtemperature is less than 60 % of saturation, the sensitivity ofthis test method to the presence of water is decreased. Forfurther information refer to RR: D27-1006.21.3.3 The suitability for this test method has not beendetermined for a liquids viscosity higher than 900 cSt at 40C
7、.1.4 Procedure Applications1.4.1 Procedure A:1.4.1.1 Procedure A is used to determine the breakdownvoltage of liquids in which any insoluble breakdown productseasily settle during the interval between the required repeatedbreakdown tests. These liquids include petroleum oils, hydro-carbons, and aska
8、rels (PCB) used as insulating and coolingliquids in transformers, cables, and similar apparatus.1.4.1.2 Procedure A may be used to obtain the dielectricbreakdown of silicone fluid as specified in Test MethodsD 2225, provided the discharge energy into the sample is lessthan 20 mJ (milli joule) per br
9、eakdown for five consecutivebreakdowns.1.4.2 Procedure B:1.4.2.1 This procedure is used to determine the breakdownvoltage of liquids in which any insoluble breakdown productsdo not completely settle from the space between the disksduring the 1min interval required in Procedure A. ProcedureB, modifie
10、d in accordance with Section 17 of Test MethodsD 2225, is acceptable for testing silicone dielectric liquids ifthe requirements of 1.4.1.2 can not be achieved.1.4.2.2 Procedure B should also be applied for the determi-nation of the breakdown voltage of liquid samples containinginsoluble materials th
11、at settle from the specimen during testing.These may include samples taken from circuit breakers, loadtap changers, and other liquids heavily contaminated withinsoluble particulate material. These examples representsamples that may have large differences between replicatetests. The use of Procedure
12、B will result in a more accuratevalue of breakdown voltage when testing such liquids.1.4.2.3 Use Procedure B to establish the breakdown voltageof an insulating liquid where an ASTM specification does notexist or when developing a value for an ASTM guide orstandard. Procedure A may be used once the s
13、ingle operatorprecision of 13.1 has been demonstrated.1.5 Both the SI and inch-pound units are equally acceptable.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate s
14、afety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:3D 923 Practices for Sampling Electrical Insulating LiquidsD 1816 Test Method for Dielectric Breakdown Voltage ofInsulating Oils of Petroleum Origin Using VDE
15、Electrodes1This test method is under the jurisdiction of ASTM Committee D27 onElectrical Insulating Liquids and Gases and is the direct responsibility of Subcom-mittee D27.05 on Electrical Test.Current edition approved Oct. 1, 2007. Published October 2007. Originallyapproved in 1946. Last previous e
16、dition approved in 2002 as D 87702e2.2RR: D271006, Round-Robin Data Using Modified VDE Electrode Cell forDielectric Strength Tests on Oil, is available from ASTM Headquarters.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For
17、 Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.D 2225 Test Methods for Silicone Fluids Used for ElectricalInsulationD
18、2864 Terminology Relating to Electrical Insulating Liq-uids and GasesD 3487 Specification for Mineral Insulating Oil Used inElectrical ApparatusD 4652 Specification for Silicone Fluid Used for ElectricalInsulationD 5222 Specification for High Fire-Point Mineral ElectricalInsulating Oils2.2 IEEE Stan
19、dards:4Standard 4, IEEE Standard Techniques for High-VoltageTestingC57.106 Guide for Acceptance and Maintenance of Insu-lating Oil in Equipment3. Significance and Use3.1 The dielectric breakdown voltage is a measure of theability of an insulating liquid to withstand electrical stress. Thepower-frequ
20、ency breakdown voltage of a liquid is reduced bythe presence of contaminants such as cellulosic fibers, conduct-ing particles, dirt, and water. A low result in this test methodindicates the presence of significant concentrations of one ormore of these contaminants in the liquid tested. See AppendixX
21、1.3.2 A high breakdown voltage measured in this test methoddoes not necessarily indicate that the amount of the contami-nants present in a liquid from which the sample was taken aresufficiently low for the sampled liquid to be acceptable in allelectrical equipment. Test Method D 877 is not sensitive
22、 to lowlevels of these contaminants. Breakdown in this test method isdominated by events occurring at the electrode edges. Thevoltage stress distribution between the parallel disk electrodesused in this test method are quasi-uniform and there issubstantial stress concentration at the sharp edges of
23、the flatdisk faces.3.3 This test method may be used for evaluation of insulat-ing liquids in equipment that is designed to be filled withunprocessed liquids as delivered by a vendor.3.4 This test method is not recommended for evaluation ofthe breakdown voltage of liquids used in equipment thatrequir
24、es the application of vacuum and filtering of the oilbefore being placed into service. Test Method D 1816 shouldbe used to determine the breakdown voltage of filtered anddegassed liquids.3.5 This test method is used in laboratory or field tests. Forfield breakdown results to be comparable to laborat
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD87720022007STANDARDTESTMETHODFORDIELECTRICBREAKDOWNVOLTAGEOFINSULATINGLIQUIDSUSINGDISKELECTRODES

链接地址:http://www.mydoc123.com/p-512379.html