1、Designation: D 849 05Standard Test Method forCopper Strip Corrosion by Industrial AromaticHydrocarbons1This standard is issued under the fixed designation D 849; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revi
2、sion. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This test method covers the corrosiveness of
3、 industrialaromatic hydrocarbons to a copper strip.NOTE 1For a similar copper strip test applicable to other petroleumproducts, see Test Method D 130 and Test Method D 1838.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3
4、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific haza
5、rdstatements, see Section 8.2. Referenced Documents2.1 ASTM Standards:2B 152/B 152M Specification for Copper Sheet, Strip, Plate,and Rolled BarD 130 Test Method for Corrosiveness to Copper fromPetroleum Products by the Copper Strip TestD 1838 Test Method for Copper Strip Corrosion by Lique-fied Petr
6、oleum (LP) GasesD 4790 Terminology of Aromatic Hydrocarbons and Re-lated Chemicals2.2 Other Documents:OSHA Regulations, 29 CFR, paragraphs 1910.1000 and1910.120032.3 ASTM Adjuncts:ASTM Copper Strip Corrosion Standards (13 photolithedaluminum strips; includes Test Method D 130)43. Terminology3.1 See
7、Terminology D 4790 for definition of terms used inthis test method.4. Summary of Test Method4.1 A polished copper strip is immersed in 200 mL ofspecimen in a flask with a condenser and placed in boilingwater for 30 min. At the end of this period, the copper strip isremoved and compared with the ASTM
8、 Copper Strip Corro-sion Standards.5. Significance and Use5.1 This test method is suitable for setting specifications, foruse as an internal quality control tool, and for use in develop-ment or research work on industrial aromatic hydrocarbons andrelated materials. It also gives an indication of the
9、 presence ofcertain corrosive substances which may corrode equipment,such as acidic compounds or sulfur compounds.6. Apparatus6.1 Flask, of sufficient size to allow for refluxing 200 mLspecimen, of chemically resistant glass with flat bottom andvial mouth.6.2 Glass Condenser, length may vary, with t
10、he insidediameter of the condenser tube not less than 10 mm. A cork isused to connect the flask with the condenser. A condenser andflask with ground-glass joints may also be used.6.3 Strip Polishing Vise, (optional), to hold the copper stripfirmly without marring the edges. For convenient vises see
11、TestMethod D 130.1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.01 on Benzene, Toluene, Xylenes, Cyclohexane, and TheirDerivatives.Current edition approved July 1, 2005. Published Jul
12、y 2005. Originally approvedin 1945. Last previous edition approved in 2003 as D 849 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summar
13、y page onthe ASTM website.3Available from U.S. Government Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401.4Available from ASTM International Headquarters. Request Adjunct No.ADJD0130. Names of suppliers in the United Kingdom can be obtained fr
14、om theInstitute of Petroleum. Two master standards are held by the IP for reference.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.4 Water Bath, of convenient desig
15、n, able to maintainboiling water such that the contents of the flask are submergedduring the test.7. Reagents and Materials7.1 Wash SolventAny volatile, sulfur-free hydrocarbonsolvent may be used provided that it shows no tarnish at allwhen tested at 100C for 1 h. Isooctane (WarningSee 8.2)isa suita
16、ble solvent.7.2 Surface Preparation/Polishing Materials, 00 grade orfiner steel wool or silicon carbide grit paper or cloth of varyingdegrees of fineness including 65-m (240-grit) grade; also asupply of 105-m (150-mesh) size silicon carbide grain orpowder and absorbent cotton (cotton wool). A commer
17、cialgrade is suitable, but pharmaceutical grade is most commonlyavailable and is acceptable.7.3 Copper StripsUse strips 12.5 mm 6 1 mm wide, 1.5to 3.5 mm thick, cut 75 mm 6 3 mm long from smooth-surfaced, hard-tempered, cold-finished copper of 99.9 + %purity. Electrical bus-bar stock is generally su
18、itable (hard-temper, cold-finished type-electrolytic tough pitch (ETP) cop-per conforming to UNS C11000 in Specification B 152/B 152M. Drill a 3.2 mm 6 0.5 mm hole approximately 3.2 mmfrom one end in the center of the strip. The strips may be usedrepeatedly but should be discarded when surfaces beco
19、medeformed on handling.7.4 Copper wire, soft, about 150 mm in length.7.5 ASTM Copper Strip Corrosion Standards, consisting ofreproductions in color of typical test strips representing in-creasing degrees of tarnish and corrosion. The reproductionsare encased in plastic in the form of a plaque. Instr
20、uctions forcare and use are given on the reverse side of each plaque andin Test Method D 130.7.6 Ashless Filter Paper or Disposable Gloves, for use inprotecting the copper strip from coming in contact with theindividual during final polishing.8. Hazards8.1 Consult current OSHA regulations, suppliers
21、 MaterialSafety Data Sheets, and local regulations for all materials usedin this test method.8.2 Isooctane is Extremely Flammable. Harmful if inhaled.Vapors may cause flash fire. Keep away from heat, sparks, andopen flame. Keep container closed. Use with adequate venti-lation. Avoid buildup of vapor
22、s and eliminate all sources ofignition, especially non-explosion-proof electrical apparatusand heaters. Avoid prolonged breathing of vapor or spray mist.Avoid prolonged or repeated skin contact.9. Preparation of Strips9.1 Surface PreparationRemove all surface blemishesfrom all six sides of the strip
23、 obtained from a previous analysis(see Note 2). One way to accomplish this is to use 00 grade orfiner steel wool or silicon carbide grit paper or cloth of suchdegrees of fineness as are needed to accomplish the desiredresults efficiently. Finish with 65-m (240-grit) silicon-carbidepaper or cloth, re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD8492005STANDARDTESTMETHODFORCOPPERSTRIPCORROSIONBYINDUSTRIALAROMATICHYDROCARBONS 用工 芳香烃 测试 腐蚀性 标准

链接地址:http://www.mydoc123.com/p-512302.html