ASTM D847-2008 Standard Test Method for Acidity of Benzene Toluene Xylenes Solvent Naphthas and Similar Industrial Aromatic Hydrocarbons《苯、甲苯、二甲苯、溶剂石脑油和类似的工业芳烃酸度的标准试验方法》.pdf
《ASTM D847-2008 Standard Test Method for Acidity of Benzene Toluene Xylenes Solvent Naphthas and Similar Industrial Aromatic Hydrocarbons《苯、甲苯、二甲苯、溶剂石脑油和类似的工业芳烃酸度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D847-2008 Standard Test Method for Acidity of Benzene Toluene Xylenes Solvent Naphthas and Similar Industrial Aromatic Hydrocarbons《苯、甲苯、二甲苯、溶剂石脑油和类似的工业芳烃酸度的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 847 08Standard Test Method forAcidity of Benzene, Toluene, Xylenes, Solvent Naphthas,and Similar Industrial Aromatic Hydrocarbons1This standard is issued under the fixed designation D 847; the number immediately following the designation indicates the year oforiginal adoption or, in t
2、he case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 Thi
3、s test method is intended for the detection of acidityand for the quantitative determination of acidity of benzene,toluene, xylenes, solvent naphthas, and similar industrial aro-matic hydrocarbons.1.2 In determining the conformance of the test results usingthis method to applicable specifications, r
4、esults shall berounded off in accordance with the rounding-off method ofPractice E29.1.3 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.4 This standard does not purport to address all of thesafety concerns, if any, associated
5、 with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements see Section 8.2. Referenced Documents2.1 ASTM Standards:2D 1193 Specificati
6、on for Reagent WaterD 3437 Practice for Sampling and Handling Liquid CyclicProductsE29 Practice for Using Significant Digits in Test Data toDetermine Conformance with Specifications2.2 Other Documents:OSHA Regulations, 29CFR paragraphs 1910.1000 and1910.120033. Terminology3.1 Definitions:3.1.1 acidi
7、ty, nthe number of milligrams of sodium hy-droxide consumed when 100 mL of the specimen are titratedunder the conditions prescribed in this test method.3.1.2 acid reaction, na characteristic of materials produc-ing the acid-color of the indicator used under the conditionsprescribed in this test meth
8、od.3.1.3 alkaline or basic reaction, na characteristic of thematerials producing the alkali-color of the indicator used underthe conditions prescribed in this test method.4. Summary of Test Method4.1 The acidity of aromatic hydrocarbons is detected anddetermined quantitatively using a sodium hydroxi
9、de titrationand a color change in a phenolphthalein indicator.5. Significance and Use5.1 This test method is suitable for setting specifications, foruse as an internal quality control tool, and for use in develop-ment or research work on industrial aromatic hydrocarbons andrelated materials. This te
10、st method gives an indication ofresidual acidity and is a measure of the quality of the finishedproduct. It is an indication of the tendency of the product tocorrode equipment.6. Interferences6.1 Tests for acidity are not applicable in the presence ofcontaminating acidic or alkaline gases, soaps, sa
11、lts, or othercompounds derived from the atmosphere or apparatus. Thecontainer holding the specimen, and the apparatus, water,indicator, and other materials used in the test shall be chosen sothat they themselves shall not appreciably affect the results.Since new corks used in specimen bottles often
12、are bleachedwith oxalic acid, it is advisable to rinse them thoroughly andcheck them for neutrality with the indicator used in the test.Glassware shall be of acid-resistant and alkali-resistant glass4and shall be rinsed with neutral distilled water before use. The1This test method is under the juris
13、diction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.01 on Benzene, Toluene, Xylenes, Cyclohexane and TheirDerivatives.Current edition approved Dec. 1, 2008. Published December 2008. Originallyapproved in 1945. Last previous
14、edition approved in 2004 as D 847 04.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Available from U.S. Gov
15、ernment Printing Office Superintendent of Documents,732 N. Capitol St., NW, Mail Stop: SDE, Washington, DC 20401, http:/www.access.gpo.gov.4Borosilicate glass or the equivalent has been found satisfactory for this purpose.1*A Summary of Changes section appears at the end of this standard.Copyright A
16、STM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.room in which the test is performed shall be chosen so as toprevent undue contamination by carbon dioxide, ammonia, orother interfering substances that may be present in the atmo-sphere.6.2 The dis
17、tilled water used in the test shall not alter thecomposition of the specimen nor otherwise interfere with thepurpose of the work. Although inert impurities often may beneglected, care must be exercised to correct for impurities or toeliminate them entirely if they are likely to interfere. When thedi
18、stilled water does not show an acid or alkaline reaction, itmay be used without further adjustment to neutrality. However,if the water shows an acid or alkaline reaction, it shall bebrought to a persistent pink end point before use by titrationwith standard 0.01 N NaOH solution (see 8.5) or standard
19、 0.01N H2SO4, respectively.7. Apparatus7.1 Graduate, 100-mL.47.2 Bottle, 500-mL glass-stoppered.47.3 Buret, 10-mL, graduated in 0.05-mL subdivisions.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is intended thatall reagents shall c
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD8472008STANDARDTESTMETHODFORACIDITYOFBENZENETOLUENEXYLENESSOLVENTNAPHTHASANDSIMILARINDUSTRIALAROMATICHYDROCARBONS

链接地址:http://www.mydoc123.com/p-512295.html