1、Designation: D76/D76M 11 (Reapproved 2016)Standard Specification forTensile Testing Machines for Textiles1This standard is issued under the fixed designation D76/D76M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of las
2、t revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the operating characteristics ofthree types of tensile testing machines used for the determina-
3、tion of the force-elongation properties of textile materials.These types of tensile testing machines are:1.1.1 Constant-rate-of-extension, CRE.1.1.2 Constant-rate-of-traverse, CRT.1.1.3 Constant-rate-of-loading (force), CRL.1.2 Specifications for tensile testing machines to measureother tensile-rela
4、ted properties of textile materials not coveredby this standard are given in the ASTM standards using thosemachines.1.3 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsyst
5、em shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1.4 The following safety hazards caveat pertains only to thetest methods described in this specification: This standard doesnot purport to address all of the safety concer
6、ns, if any,associated with its use. It is the responsibility of the user of thisstandard to establish appropriate safety and health practicesand determine the applicability of regulatory limitations priorto use.2. Referenced Documents2.1 ASTM Standards:2D123 Terminology Relating to TextilesD2256 Tes
7、t Method for Tensile Properties of Yarns by theSingle-Strand MethodD4849 Terminology Related to Yarns and FibersE4 Practices for Force Verification of Testing MachinesE74 Practice of Calibration of Force-Measuring Instrumentsfor Verifying the Force Indication of Testing Machines3. Terminology3.1 For
8、 terminology related to tensile testing, see Terminol-ogy D4849.3.1.1 The following terms are relevant for this standard:bench marks, calibrate, capacity, clamp, constant-rate-of ex-tension type tensile testing machine (CRE), constant-rate-of-load tensile testing machine (CRL), constant-rate-of-trav
9、ersetensile testing machine (CRT), effective carriage mass, effec-tive gauge length, grip, jaw face, jaw liner, jaws, least count,nominal gauge length, response time, sensitivity, in electronicsystems, sensitivity, stress, tensile testing machine, test skein,time-to-break, true gauge length.3.1.2 Fo
10、r all other terminology related to textiles, seeTerminology D123.4. Performance Requirements4.1 Individual ASTM methods for tensile testing of textilematerials that prescribe apparatus which conforms to thisspecification shall also include such other detailed specifica-tions as may be necessary to d
11、escribe the testing machine andits operation completely.4.1.1 This specification shall not be construed as beingintended to preclude the evolution of improved methods oftesting or testing apparatus, which is recognized as being vitalin an advancing technology.4.2 Comparison of results from tensile t
12、esting machinesoperating on different principles is not recommended. Whenthese machines are used for comparison testing however,constant time-to-break at 20 6 3 s is the established way ofproducing data, but even then the data may differ significantly.4.2.1 Comparison of test data from machines of t
13、he sametype, especially two or more CRT-type or two or moreCRL-type machines, requires consideration of the effect ofindividual machine characteristics; for example, inertia effects,capacity, sensitivity, type of loadcell, etc., which may causesignificant differences in results even though uniform p
14、roce-dures are employed. Data from different CRE-type testingmachines, however, should not be significantly different.4.2.2 In any case, all types of tensile testing machines mustsatisfy the accuracy requirements as given in Section 7.1This specification is under the jurisdiction of ASTM Committee D
15、13 onTextiles and is the direct responsibility of Subcommittee D13.58 on Yarns andFibers.Current edition approved July 1, 2016. Published July 2016. Originally approvedin 1920 . Last previous edition approved in 2011 as D76 11. DOI: 10.1520/D0076_D0076M-11R16.2For referenced ASTM standards, visit th
16、e ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandardsvolume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. Un
17、ited States14.3 While changes in humidity affect the tensile propertiesof many textile materials, changes in humidity normally do notaffect the testing machines themselves.4.4 When machines are moved to different locations, theircalibration shall be verified to make sure that they still meet thespec
18、ified tolerances.4.5 When each of the sub-systems (force, extension, clamp-ing) has been individually calibrated, verified, or checked, it isrecommended that the total system be verified using a standardmaterial appropriate for the type testing to be carried out.3Thistesting of the total system is t
19、he established way of ensuringthat the clamping system is operating properly.5. Apparatus5.1 Tensile Testing MachinesTensile testing machines fortextile materials are classified according to their operatingprinciple as follows:Type Principle of OperationCRE Constant rate-of-extensionCRT Constant rat
20、e-of-traverse (pendulum type)CRL Constant rate-of-load (inclined plane type)5.1.1 CRE-TypeA testing machine in which the pullingclamp moves at a uniform rate, and when loaded at themaximum allowable force the force-measuring mechanism(load cell) moves a negligible distance of less than 0.13 mm0.005
21、in.5.1.2 CRT-TypeA testing machine in which the pullingclamp moves at a uniform rate and the force is applied throughthe other clamp, which moves appreciably to actuate a force-measuring mechanism, producing a rate of increase of force orextension which is usually not constant and is dependent on th
22、eextension characteristics of the specimen.5.1.3 CRL-TypeA testing machine in which the rate ofincrease of the force is uniform with time after the first3sandthe specimen is free to elongate, this elongation being depen-dent upon the extension characteristics of the specimen at anyapplied force.5.1.
23、4 Multiple-Purpose TypeMachines capable of beingoperated as both a CRE-type and a CRL-type may be used.5.2 Measuring DevicesMachines shall be equipped with asuitable device for measuring the force and, when needed, adevice to measure extension. Preferably, the data must beelectronically stored using
24、 a data-acquisition system, or at leastthe curve shall be recorded graphically, or the force andextension data may be indicated on appropriate scales ordisplays.5.2.1 Most testing machines record only force-extensiondata. When the capacity of a testing machine is adjusted to fitthe predetermined lin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD76D76M20112016STANDARDSPECIFICATIONFORTENSILETESTINGMACHINESFORTEXTILES 纺织品 拉伸 试验 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-512155.html