ASTM D619-2014 Standard Test Methods for Vulcanized Fibre Used for Electrical Insulation《电绝缘用硫化纤维的标准试验方法》.pdf
《ASTM D619-2014 Standard Test Methods for Vulcanized Fibre Used for Electrical Insulation《电绝缘用硫化纤维的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D619-2014 Standard Test Methods for Vulcanized Fibre Used for Electrical Insulation《电绝缘用硫化纤维的标准试验方法》.pdf(8页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D619 14 An American National StandardStandard Test Methods forVulcanized Fibre Used for Electrical Insulation1This standard is issued under the fixed designation D619; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, th
2、e year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods cover the procedures for testingvulcanized fibre sheets, tubes, and rods of such grades
3、as canbe used for electrical insulation.1.2 The procedures appear in the following sections:Procedure SectionArc resistance 23Ash 6Bond strength (ply adhesion) 16Bursting strength 14Compressive strength 12, 25, 30Conditioning 4Density 17, 26, 32Dielectric strength 18, 27Dimensional measurements 28,
4、33Flammability 22Flexural strength 13, 31Silica 7Tearing strength 11Tensile strength 10, 24, 29Thickness (sheets) 20Resistance to impact 15Rockwell hardness 19Volatile matter 8Water absorption 5Zinc chloride 91.3 The values stated in inch-pound units are to be regardedas the standard. The SI values
5、given in parentheses are forinformation only.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regula
6、tory limitations prior to use. Specific hazardstatements are given in 7.3, 22.1, 22.2.NOTE 1The test methods described herein are similar technically tothose described in IEC Publication 60667-2. Not all of the tests in thisdocument are included in IEC 60667-2, and the procedures in the twopublicati
7、ons are not completely identical; but it is expected that compa-rable results will be obtained from most of the procedures. Conductcomparative tests if necessary before directly comparing results of testsusing the different procedures.2. Referenced Documents2.1 ASTM Standards:2D149 Test Method for D
8、ielectric Breakdown Voltage andDielectric Strength of Solid Electrical Insulating Materialsat Commercial Power FrequenciesD202 Test Methods for Sampling and Testing UntreatedPaper Used for Electrical InsulationD229 Test Methods for Rigid Sheet and Plate MaterialsUsed for Electrical InsulationD256 Te
9、st Methods for Determining the Izod PendulumImpact Resistance of PlasticsD348 Test Methods for Rigid Tubes Used for ElectricalInsulationD349 Test Methods for Laminated Round Rods Used forElectrical InsulationD374 Test Methods for Thickness of Solid Electrical Insu-lation (Withdrawn 2013)3D495 Test M
10、ethod for High-Voltage, Low-Current, Dry ArcResistance of Solid Electrical InsulationD570 Test Method for Water Absorption of PlasticsD668 Test Methods of Measuring Dimensions of Rigid Rodsand Tubes Used for Electrical InsulationD689 Test Method for Internal Tearing Resistance of Paper(Withdrawn 200
11、9)3D695 Test Method for Compressive Properties of RigidPlasticsD710 Specification for Vulcanized Fibre Sheets, Rods, andTubes Used for Electrical InsulationD785 Test Method for Rockwell Hardness of Plastics andElectrical Insulating MaterialsD792 Test Methods for Density and Specific Gravity (Rela-ti
12、ve Density) of Plastics by DisplacementD828 Test Method for Tensile Properties of Paper andPaperboard Using Constant-Rate-of-ElongationApparatus(Withdrawn 2009)31These test methods are under the jurisdiction of ASTM Committee D09 onElectrical and Electronic Insulating Materials and are the direct re
13、sponsibility ofSubcommittee D09.07 on Flexible and Rigid Insulating MaterialsCurrent edition approved Nov. 1, 2014. Published December 2014. Originallyapproved in 1941. Last previous edition approved in 2004 as D619 99 (2004)which was withdrawn January 2013 and reinstated in November 2014. DOI:10.15
14、20/D0619-14.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3The last approved version of this historical sta
15、ndard is referenced onwww.astm.org.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States1D952 Test Method for Bond or Cohesive Strength of SheetPlastics and Electrical Insulat
16、ing MaterialsD1711 Terminology Relating to Electrical InsulationD6054 Practice for Conditioning Electrical Insulating Mate-rials for Testing (Withdrawn 2012)32.2 IEC Standard:IEC 60667-2 Specification for Vulcanized Fibre for Electri-cal PurposesPart 2: Methods of Test43. Terminology3.1 DefinitionsF
17、or definitions of terms used in this stan-dard refer to Terminology D1711.3.2 Definitions of Terms Specific to This Standard:3.2.1 In referring to the cutting of specimens and theapplication of the load, the following definitions of termsapply. These definitions of terms correspond to normal practic
18、ein the paper industry.3.2.2 vulcanized fibre, na material made from chemicallygelatinized cellulosic paper or board using zinc chloride as thegelatinizing agent.3.2.2.1 DiscussionThe zinc chloride is subsequently re-moved by leaching. The resulting product, after being driedand finished by calender
19、ing, is a material of partially regener-ated cellulose in which the fibrous structure is retained invarying degrees depending on the grade of paper used and onthe processing conditions. Material up to about 3.2 mm inthickness is produced by bonding multiple layers of paper (orboard) after chemical t
20、reatment. Vulcanized fibre thicker than3.2 mm is typically produced by laminating multiple plies ofvulcanized fibre together. Vulcanized fibre does not containvulcanized rubber or sulfur as the name might imply. Thinvulcanized fibre has sometimes been termed “fish paper.” Formore detail on vulcanize
21、d fibre refer to Specification D710.3.2.3 lengthwise (LW), adjthe direction of the sheet whichis strongest in flexure.3.2.3.1 DiscussionThis is also known as the machinedirection. It is the lengthwise direction in which the paper isformed and travels on the paper machine, wire, or cylinder.Since mak
22、ing paper (which form the plies of vulcanized fibre)is a directional process, vulcanized fibres properties differsignificantly between machine direction and cross direction.For some materials, including the raw materials used for themanufacture of materials considered herein, this direction maybe de
23、signated as the warp direction.3.2.4 crosswise (CW), adjthe direction of the sheet whichis at 90 to the lengthwise direction, and which is normally theweakest direction in flexure.3.2.4.1 DiscussionFor some materials, including the rawmaterials used for manufacture of materials considered herein,thi
24、s direction may be designated as the cross-machine directionor the weft direction. It is also known as cross direction.3.2.5 edgewise loading, vmechanical force applied in theplane of the original sheet or plate.3.2.6 flatwise loading, vmechanical force applied normalto the surfaces of the original
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD6192014STANDARDTESTMETHODSFORVULCANIZEDFIBREUSEDFORELECTRICALINSULATION 绝缘 硫化 纤维 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-511980.html