ASTM D531-2000(2005) Standard Test Method for Rubber Property-Pusey and Jones Indentation《橡胶特性的标准试验方法 普西和琼斯压痕试验》.pdf
《ASTM D531-2000(2005) Standard Test Method for Rubber Property-Pusey and Jones Indentation《橡胶特性的标准试验方法 普西和琼斯压痕试验》.pdf》由会员分享,可在线阅读,更多相关《ASTM D531-2000(2005) Standard Test Method for Rubber Property-Pusey and Jones Indentation《橡胶特性的标准试验方法 普西和琼斯压痕试验》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 531 00 (Reapproved 2005)Standard Test Method forRubber PropertyPusey and Jones Indentation1This standard is issued under the fixed designation D 531; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last r
2、evision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers the determination
3、of the inden-tation of rubber or rubber-like materials by means of the Puseyand Jones type of plastometer. This apparatus is used tomeasure the depth of indentation of an indentor, under fixedforce into the surface of a specimen.1.2 The values stated in SI units are to be regarded as thestandard.1.3
4、 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Docu
5、ments2.1 ASTM Standards:2D 618 Practice for Conditioning Plastics for TestingD 1415 Test Method for Rubber PropertyInternationalHardnessD 4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustriesNOTE 1The specific dated edition of the prac
6、tice that prevails in thisdocument is referenced in the Precision section.3. Significance and Use3.1 The Pusey and Jones indentation value is the depth ofindentation, expressed in hundredths of a millimetre, of a ball3.175 mm (0.1250 in.) in diameter under an expressed force of9.8 N (2.2 lbf). This
7、value may be used to compare theindentation resistance of rubber and rubber-like materials.3.2 The indentation value obtained should not be confusedwith hardness as measured by Test Method D 1415, since in thelatter test the rubber immediately adjacent to the indentor isprecompressed.4. Apparatus4.1
8、 Plastometer, an instrument consisting of an indentor, amass for applying the stated force on the indentor, a microme-ter for indicating the depth of the indentation, a specimenholder and support.4.1.1 Indentor, for indenting the specimen, consisting of avertical steel shaft attached, at the upper e
9、nd to a depthindicator gage, and terminating in a steel sphere having adiameter of 3.175 6 0.015 mm (0.1250 6 0.0005 in.) ofpolished, noncorrosive hard metal treated to resist wear.4.1.2 Mass, the mass shall be 1000 6 0.01 g.4.1.3 Depth Indicator Gage, a micrometer attached to theplastometer, either
10、 an electronic digital gage or analog dialgage, capable of displaying indentor movement (indentation)in increments of at least 0.01 mm (0.0004 in.) and having travelof 0 (zero) to no less than 3 mm (0.12 in).4.1.4 Support, a support frame, or fixture, for the plastom-eter, shall be configured so tha
11、t the specimen holder and hence,the specimen, are perpendicular to the indentor support shaftand that the mass may be independently raised or loweredvertically, permitting the indentor to rest on the surface of thespecimen and the mass to be subsequently applied.4.1.5 Specimen Holder, for the standa
12、rd, or reference speci-men described in 5.1, shall consist of a clamping fixture of twometal plates secured by two threaded bolts. The uppermostplate shall have a hole and a slot, as depicted in Fig. 1, to allowfor the unencumbered introduction of the indentor to thespecimen.4.1.5.1 The purpose of t
13、he specimen holder is to support thespecimen in a manner that reduces, or eliminates, relativepositioning or movement that may adversely affect test deter-minations.4.1.5.2 In routine testing, a specimen holder, a support, orboth, of other, but similar, configurations may be employed toaccommodate s
14、pecimens other than those described in 5.1,refer to 5.1.1.5. Test Specimens5.1 The standard, or reference, test specimen shall be auniform molded rectangular block a minimum of 13 mm (0.51in.) in thickness, 30 mm (1.18 in.) in width, and 75 mm (2.951This test method is under the jurisdiction of ASTM
15、 Commitee D11 on Rubberand is the direct responsibility of Subcommittee D11.10 on Physical Testing.Current edition approved May 1, 2005. Published May 2005. Originallyapproved in 1939. Last previous edition approved in 2000 as D 531 00.2For referenced ASTM standards, visit the ASTM website, www.astm
16、.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.in.) in le
17、ngth. The upper and lower surfaces, those oppositesurfaces with the largest area, shall be parallel to within 60.5mm (60.20 in).5.1.1 The standard, or reference, test specimen shall be usedwhen the plastometer is employed for the purpose of determin-ing a standard, or reference, either within or bet
18、ween labora-tories, that is, in other than routine testing.5.2 In routine testing, specimens may be used with aconfiguration other than those of the standard, or reference, testspecimen described in 5.1.6. Procedure6.1 Measurement of Indentation of Standard, or ReferenceSpecimens:6.1.1 When measurin
19、g the indentation on a standard, orreference specimen as described in 5.1, secure it in thespecimen holder (refer to Fig. 1 and Section 4.1.5) with thebolts tightened sufficiently to hold it firmly without measurablecompression.6.1.2 Place the specimen holder on the support.6.1.3 Mount the plastomet
20、er over the specimen so that theindentor shaft is perpendicular to the support and hence thespecimen holder, to within 60.05 mm (60.002 in).6.1.4 The plastometer and support shall be placed upon aflat surface in a manner that prevents unsteadiness or move-ment other than described in 6.3.6.1.5 Lower
21、 the indentor shaft until the indentor is at themoment of contact with the specimen.6.1.5.1 Adjust the depth indicator gage to record indenta-tions up to 3 mm (0.12 in).6.1.5.2 Adjust the depth indicator gage so the displayindicates zero.6.1.6 Lower the mass onto the indentor, in a fashion thatelimi
22、nates shock, until the mass rests fully on the indentor.6.1.7 The amount of indentation displayed on the depthindicator gage 60 s (61 s) after the application of a total forceof 9.8 N, shall be recorded.6.1.8 Make no less than 3 such determinations on thespecimen at least 13 mm (0.51 in) apart and f
23、rom any edge.6.1.9 The median of the determinations, expressed as awhole number indicating hundredths of millimetres, shall bereported as the Pusey and Jones Indentation Value, refer to8.1.1.6.2 Measurement of Indentation of Specimens for RoutineTests (Nonstandard Specimens):6.2.1 When making determ
24、inations on specimens other thanthose described in 5.1, specimen holders, supports or othersuitable fixturing, similar to those previously described, may beemployed and the procedure in 6.1 may be followed, other-wise:6.2.2 Mount the plastometer over, or directly upon, thespecimen, so that the inden
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD53120002005STANDARDTESTMETHODFORRUBBERPROPERTYPUSEYANDJONESINDENTATION 橡胶 特性 标准 试验 方法 西和 琼斯 压痕 PDF

链接地址:http://www.mydoc123.com/p-511855.html