1、Designation: D 2013 07Standard Practice forPreparing Coal Samples for Analysis1This standard is issued under the fixed designation D 2013; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in paren
2、theses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This practice2covers the reduction and division of grossor divided s
3、amples, and the preparation of composite samples,up to and including the individual portions for laboratoryanalysis.1.2 Reduction and division procedures are prescribed forcoals of the following groups:1.2.1 Group A includes coals that have been cleaned in allsizes.1.2.2 Group B includes all other c
4、oals. Unknown coals areto be considered under Group B.1.2.3 Group A allows smaller weight laboratory samples tobe retained than Group B. These lower weights may be used forparticular coals if they have been shown, by using theprocedures of Annex A1.2, to give a sample preparation andanalysis varianc
5、e which is no more than 20 % of the totalanalysis variance.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bi
6、lity of regulatory limitations prior to use.1.4 The values stated in SI units are to be regarded asstandard. The values given in parentheses are provided forinformation purposes only.2. Referenced Documents2.1 ASTM Standards:3D 121 Terminology of Coal and CokeD 2234/D 2234M Practice for Collection o
7、f a Gross Sampleof CoalD 3174 Test Method forAsh in theAnalysis Sample of Coaland Coke from CoalD 3302 Test Method for Total Moisture in CoalD 4749 Test Method for Performing the Sieve Analysis ofCoal and Designating Coal SizeE11 Specification for Wire Cloth and Sieves for TestingPurposesE 177 Pract
8、ice for Use of the Terms Precision and Bias inASTM Test MethodsE 456 Terminology Relating to Quality and Statistics3. Terminology3.1 Definitions of Terms Specific to This StandardNoterms are used which are specific to this practice. Many termsused in this practice may be found in Terminologies D 121
9、 andE 456 and in Practice E 177.4. Summary of Practice4.1 Three processes of sample division and reduction arecovered as follows:4.1.1 Procedure AManual riffles are used for division ofthe sample and mechanical crushing equipment for the reduc-tion of the sample.4.1.2 Procedure BMechanical sample di
10、viders are usedfor the division of the sample and mechanical crushingequipment for the reduction of the sample.4.1.3 Combined Procedure A and BThe two proceduresmay be combined at any stage.5. Significance and Use5.1 Other standards are used to collect the gross sample:Practice D 2234/D 2234 M allow
11、s for one division of the grosssample before crushing. The mass and top size of the gross ordivided sample collected by using these guides and practicesare usually too large for chemical or physical testing. PracticeD 2013 provide instructions for reducing and dividing thegross or divided sample, by
12、 on-line or off-line processes, orboth, to a top size and mass suitable to the performance of1This practice is under the jurisdiction of ASTM Committee D05 on Coal andCoke and is the direct responsibility of Subcommittee D05.23 on Sampling.Current edition approved June 1, 2007. Published July 2007.
13、Originally approvedin 1962. Last previous edition approved in 2004 as D 2013 04.2For more detailed explanation of this practice see Keller, G. E., “Determinationof Quantities Needed in Coal Sample Preparation and Analysis,” Transactions,Vol232, 1965, pp. 218-226.3For referenced ASTM standards, visit
14、 the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-295
15、9, United States.testing. Any bias in the gross or divided sample beforeadherence to this practice will remain in the final sampleresulting from use of this practice. Therefore, carefully selectthe standard to be used to collect the gross sample.5.2 Division and reduction of a sample may occur at mo
16、rethan one location. Most often, the sample is collected, reduced,and divided (one or more times) by use of a mechanicalsampling system. The remaining sample may be further di-vided on-site to facilitate transporting it to the laboratory wherefurther reduction and division likely occurs before analy
17、sis.5.3 In places, this practice requires air drying the samplebefore subsequent reduction. Procedures for air drying andair-dry loss determination are provided in Test Method D 3302.5.4 Most often, samples are reduced and divided to ananalysis sample. However, some tests may require a sample ofdiff
18、erent mass or top size. This procedure may be used toprovide a sample of any mass and size consist from the grossor divided sample to, and including, the analysis sample.5.5 This practice also specifies how to prepare compositesamples, if required.6. Apparatus6.1 Crushers or GrindersJaw, cone, or ro
19、tary crusher;hammer mill; roll; or other suitable crusher to reduce thesample to pass the sieve designated in 6.4. Hard steel or chillediron plate with tamper, sledge, or hand bar may be used forpreliminary crushing of any large lumps in the sample beforefeeding into the crusher. Crushers should be
20、designed andoperated in a manner to minimize the effect of induced aircirculation and thus the potential for drying the coal.6.1.1 Pulverizer or MillFor final reduction of laboratorysample to the 250-m (No. 60) sieve size, the followingequipment may be used:6.1.2 Hammer MillCompletely enclosed to av
21、oid loss ofdust or moisture.6.1.3 Porcelain-Jar Ball MillThis mill shall be approxi-mately 230 mm (9.0 in.) in diameter and 250 mm (10.0 in.) inheight with smooth, hard, well-rounded, flint pebbles, orequivalent, that do not increase ash content of the sample.6.1.4 Bucking Board (Chrome Steel) or Mo
22、rtar (Agate orEquivalent) and PestleOnly for reducing the small fractionof sample, not passing a 250-m (No. 60) sieve after pulveri-zation.6.2 Sample Dividers:6.2.1 MechanicalA mechanical sample divider using areciprocating or rotating cutter, a rotating hopper and spout, arotating slotted cone, a r
23、eciprocating hopper and fixed cutter,bucket cutter with either bottom dump or inverting discharge,slotted belt, rotary disk divider, mechanical stopped or movingbelt sweeper, or other acceptable devices for dividing thesample. Typical mechanical sample dividers are shown in Fig.1. These illustrate v
24、arious designs, but other acceptable designsare available.6.2.2 RiffleA manual sample divider that splits the coalstream into a number of alternate elements. Riffle slots shouldbe at least three times the top size of coal being divided. Atypical riffle is shown in Fig. 2. It is preferable that feed
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD20132007STANDARDPRACTICEFORPREPARINGCOALSAMPLESFORANALYSIS 分析 样品 制备 标准 实施 规程 PDF

链接地址:http://www.mydoc123.com/p-510845.html