ASTM D1921-2012 Standard Test Methods for Particle Size (Sieve Analysis) of Plastic Materials《塑料材料粒度(筛析)的标准试验方法》.pdf
《ASTM D1921-2012 Standard Test Methods for Particle Size (Sieve Analysis) of Plastic Materials《塑料材料粒度(筛析)的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1921-2012 Standard Test Methods for Particle Size (Sieve Analysis) of Plastic Materials《塑料材料粒度(筛析)的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1921 12Standard Test Methods forParticle Size (Sieve Analysis) of Plastic Materials1This standard is issued under the fixed designation D1921; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision.
2、 A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 These test methods cover the measurement of thepar
3、ticle size of plastic materials in the powdered, granular, orpelleted forms in which they are commonly supplied. As thesetest methods utilize dry sieving, the lower limit of measure-ment is considered to be about 38 m (No. 400 sieve). Forsmaller particle sizes, sedimentation test methods are recom-m
4、ended.1.2 Two test methods are described:1.2.1 Test Method AThis test method uses multiple sievesselected to span the particle size of the material. This methodis used to determine the mean particle diameter and particlesize distribution.1.2.2 Test Method BThis test method is an abbreviatedversion o
5、f Test MethodAconducted with a few specific sieves.This test method determines “percent passing” or “percentretained” on a given sieve. Test Method B is applicable tomaterials which do not have a normal particle size distributionsuch as pellets and cubes.1.3 The values stated in SI units shall be co
6、nsideredstandard for dimensions of the wire cloth openings and thediameter of the wires used in the wire cloth. The values statedin inch-pound units shall be considered standard with regard tothe sieve frames.1.4 This standard does not purport to address all of thesafety concerns, if any, associated
7、 with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 1There is no known ISO equivalent for this test method.2. Referenced Documents2.1 ASTM Standards:2E11
8、 Specification for Woven Wire Test Sieve Cloth and TestSievesE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Summary of Test Methods3.1 A dry mass of plastic material is placed on a series ofsieves arranged in order of increasing fineness and the ma
9、ss isdivided into fractions corresponding to the sieve opening.4. Significance and Use4.1 These test methods are used to determine particle sizedistribution and therefore are useful for determining lot-to-lotuniformity.4.2 The particle sizes of plastic materials affect the handlingcharacteristics an
10、d sometimes will affect the processing char-acteristics of some polymers.5. Interferences5.1 Some materials develop a static charge during sieving.This charge interferes with the sieving process and results in acoarse bias. Use of an antistat is necessary to obtain meaning-ful results.5.2 The choice
11、 of antistat (or slip agent) has been known toaffect the coarse bias. Some materials are more effective inaiding the fines to separate from the mass.5.3 Too much material on a sieve causes mass blinding andresults in a coarse bias. The sieve selection and charge weightmust be chosen to avoid overloa
12、ding any sieve.1These test methods are under the jurisdiction of ASTM Committee D20 onPlastics and are the direct responsibility of Subcommittee D20.70 on AnalyticalMethods (Section D20.70.01).Current edition approved Aug. 1, 2012. Published September 2012. Originallyapproved in 1961. Last previous
13、edition approved in 2006 as D1921 - 061. DOI:10.1520/D1921-12.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website
14、.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.4 Wavy, improperly stretched wire-cloth potentially al-lows wires to separate without being visually damaged. Sieveswi
15、th wavy or torn wires shall not be used, as they no longerconform to Specification E11.6. Apparatus6.1 Balance, 500-g minimum capacity with the capability ofreading to the nearest 0.1 g.6.2 Mechanical Sieving Device and Time SwitchA me-chanical sieve-shaking device equipped with an automatic timeswi
16、tch. This device shall be capable of imparting uniformrotary motion and a tapping action at a rate of 150 6 10taps/min.6.3 Wire Cloth Sieves, woven wire cloth conforming toSpecification E11, as shown in Table 1, mounted in 8-in.203-mm frames. The number of sieves and the choice of sizesshall be sele
17、cted for the material being tested. A cover and abottom pan are also required.6.4 Accessories for Cleaning the Screens:6.4.1 Brush3,6.4.2 Vacuum Cleaner, and6.4.3 Air Hose.7. Reagents and Materials7.1 Antistat (or slip) agent suitable to the material beingtested.8. Hazards8.1 The sieving operation a
18、nd cleaning of the sieves some-times introduce fine plastic particles and antistat agent into theatmosphere. Take precautions to avoid breathing these par-ticles.9. Sampling9.1 Homogenize the lot where possible before removing thetest sample to avoid segregation of particles during handling.10. Prep
19、aration of Apparatus10.1 Thorough cleaning and inspection of the sieve arerequired prior to initiating a test. Carefully clean the sieveswith a brush and vacuum cleaner or compressed air, or both.Periodic washing with soap and water or suitable solvent isrecommended with some materials.10.2 Tare eac
20、h sieve and the pan. Record tare weights to thenearest 0.1 g.10.3 Assemble sieves so that the sieve openings decrease insize in sequence from the top of the stack. Place the pan at thebottom.10.4 Use full- or half-size screens to accommodate theholder in the shaker.11. Conditioning11.1 The plastic m
21、aterial must be in a free-flowing condi-tion.11.2 If possible, condition the material to the laboratorytemperature and humidity.TEST METHOD A12. Procedure12.1 Select sieves in sufficient number to cover the expectedrange of particle sizes, and nest them together in order ofdiminishing opening with t
22、he coarsest sieve on top and the panon the bottom.12.2 Select sieves in sufficient number to have significantmeasurable quantities on four or more sieves. Weigh the sieveson a balance reading to the nearest 0.1 g. Record these sievemasses as their tare masses, respectively.12.3 Weigh 50 g of sample
23、to the nearest 0.1 g and transferit to the top of the stack. Record the sample weight used. Largesample size causes screen blinding and will skew the results tothe coarse particle size. A screen is considered blinded if it isholding 20 or more g. For repeatable results, use a smallersample size.NOTE
24、 2For some materials an antistat (or slip agent) is needed. Add1 % of the antistat (or slip agent) to the sample and mix in with a spatula.With polyvinyl chloride resins, it has been found that the distribution willskew to either the fine or the coarse particle size depending on the antistatused. Re
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD19212012STANDARDTESTMETHODSFORPARTICLESIZESIEVEANALYSISOFPLASTICMATERIALS 塑料 材料 粒度 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-510687.html