ASTM D1618-1999(2011) Standard Test Method for Carbon Black ExtractablesTransmittance of Toluene Extract《炭黑可萃取性的标准试验方法 甲苯萃取物的透射系数》.pdf
《ASTM D1618-1999(2011) Standard Test Method for Carbon Black ExtractablesTransmittance of Toluene Extract《炭黑可萃取性的标准试验方法 甲苯萃取物的透射系数》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1618-1999(2011) Standard Test Method for Carbon Black ExtractablesTransmittance of Toluene Extract《炭黑可萃取性的标准试验方法 甲苯萃取物的透射系数》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1618 99 (Reapproved 2011)Standard Test Method forCarbon Black ExtractablesTransmittance of TolueneExtract1This standard is issued under the fixed designation D1618; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the measurement of the degreeof toluene discoloration by carbon black extractables and
3、 isuseful in controlling the reaction processes for production ofcarbon black. This test method may not be applicable to carbonblacks with high extractables.1.2 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.3 This standard d
4、oes not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM St
5、andards:2D1799 Practice for Carbon BlackSampling PackagedShipmentsD1900 Practice for Carbon BlackSampling Bulk Ship-mentsD4483 Practice for Evaluating Precision for Test MethodStandards in the Rubber and Carbon Black ManufacturingIndustries3. Terminology3.1 Definition:3.1.1 carbon black toluene disc
6、oloration, n the transmit-tance, at 425 nm, of the filtrate obtained from the tolueneextract of carbon black, compared to that of pure toluene.4. Significance and Use4.1 The toluene discoloration value provides an estimate oftoluene-soluble discoloring residues present on the carbonblack.5. Apparatu
7、s and Reagent5.1 Spectrophotometer, with tungsten filament lamp, 20-nmmaximum spectral bandpass, capable of measuring percenttransmittance at a 425-nm wavelength. The instrument is to beoperated in accordance with the manufacturers directions foroptimum performance.5.2 Cuvets, rectangular, with an o
8、ptical light path of 10 mm.5.3 Balance, analytical, with a sensitivity of 60.01 g.5.4 Oven, gravity-convection type, capable temperatureregulation within 61C at 125C and temperature uniformitywithin 65C.5.5 Pipet, automatic, bottle-type, 20 cm3, with a repeatabil-ity of 60.1.5.6 Erlenmeyer Flasks, 1
9、25 cm3with ground-glass stopper.5.7 Filter Paper, qualitative grade, medium retention,medium-fast filter speed, 150-mm diameter.5.8 Glass Filtering Funnels, 75-mm inside diameter at thetop.5.9 Beakers,50or100cm3, with pouring lips.5.10 Wiping Paper, lint-free.5.11 Cotton Swabs.5.12 Fume Hood, fully
10、enclosed on three sides, with spark-proof fan and motor.5.13 Toluene, analytical reagent grade.6. Sampling6.1 Samples shall be taken in accordance with PracticeD1799 or Practice D1900.7. Standardization of Apparatus7.1 Turn on the spectrophotometer and allow it to warm forthe length of time specifie
11、d by the manufacturer.7.2 Check the zero reading of the spectrophotometer inaccordance with the manufacturers instructions, and adjust ifnecessary.1This test method is under the jurisdiction of ASTM Committee D24 on CarbonBlack and is the direct responsibility of Subcommittee D24.31 on Non-CarbonBla
12、ck Components of Carbon Black.Current edition approved May 1, 2011. Published July 2011. Originally approvedin 1965. Last previous edition approved in 2004 as D1618 99 (2004). DOI:10.1520/D1618-99R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Servic
13、e at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7.3 Place the funnel with the filter paper int
14、o an Erlenmeyerflask. Filter approximately 30 cm3of toluene into the flask andstopper the flask.7.4 Pour a portion of the toluene into the beaker with thepouring lip for simplifying the transfer of the toluene to thecuvet.7.5 Rinse the cuvet with the filtered toluene three times,filling approximatel
15、y one third full each time. Discard thisrinsing toluene into an approved safety container.NOTE 1The cuvet must be handled on the ground-glass sides only. Donot touch the smooth, clear sides with the fingers.7.6 Fill the cuvet and wipe the outside surfaces with thelint-free wiping paper while holding
16、 the cuvet in front of asuitable light source. The toluene must be free of any contami-nants, such as lint particles, which might cause light scattering,thus influencing the test results. If necessary, rewipe the outsideuntil perfectly clean, or clean the inside surfaces with a cottonswab. Repeat 7.
17、5 if the inside surfaces are cleaned.7.7 . Insert the cuvet into the spectrophotometer and adjustit to read 100 % transmittance at the 425-nm wavelength.8. Procedure8.1 Dry an adequate sample of carbon black at 125 6 1Cfor 60, +5, 0 min, using a gravity-convection oven.NOTE 2An infrared lamp must no
18、t be used for drying samples, as itwill vaporize some of the extractable materials.8.2 Allow the sample to cool to room temperature in adesiccator.8.3 Weigh 2.00 6 0.01 g of the carbon black and transfer itto a 125-cm3Erlenmeyer flask with ground-glass stopper.8.4 Add 20 cm3of toluene to the sample
19、flask and stopperthe flask.NOTE 3If necessary, larger quantities of carbon black and toluenemay be used, but the quantities must remain in this ratio of 1 g/10 cm3oftoluene.8.5 Without delay, shake the mixture vigorously either byhand or machine for 60, +5, 0 s.8.6 Immediately pour as much of the mi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD161819992011STANDARDTESTMETHODFORCARBONBLACKEXTRACTABLESTRANSMITTANCEOFTOLUENEEXTRACT 炭黑 萃取 标准 试验

链接地址:http://www.mydoc123.com/p-510162.html