ASTM D1599-2018 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe Tubing and Fittings.pdf
《ASTM D1599-2018 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe Tubing and Fittings.pdf》由会员分享,可在线阅读,更多相关《ASTM D1599-2018 Standard Test Method for Resistance to Short-Time Hydraulic Pressure of Plastic Pipe Tubing and Fittings.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D1599 18Standard Test Method forResistance to Short-Time Hydraulic Pressure of PlasticPipe, Tubing, and Fittings1This standard is issued under the fixed designation D1599; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision
2、, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope*1.1 This test method
3、covers the determination of the resis-tance of thermoplastic pipe, tubing and fittings, and reinforcedthermosetting pipe and reinforced thermoplastic pipe to hy-draulic pressure in a short time period. Procedure A is used todetermine burst pressure of a specimen if the mode of failureis to be determ
4、ined. Procedure B is used to determine that aspecimen complies with a minimum burst requirement.NOTE 1Reinforced thermoplastic pipe is a three-layer constructionconsisting of a thermoplastic core layer around which is wound acontinuous helical reinforcement layer. A protective thermoplastic coverlay
5、er is applied over the reinforcement. For design and pressure, thethermoplastic core and cover layers are not considered hoop stress bearingelements. All of the hoop stress is taken up by the reinforcement layer.1.2 This test method is suitable for establishing laboratorytesting requirements for qua
6、lity control purposes or for pro-curement specifications.1.3 The values stated in inch-pound units are to be regardedas standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.4 This standard does not p
7、urport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environmental practices and deter-mine the applicability of regulatory limitations prior to use.1.5 This international stan
8、dard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. R
9、eferenced Documents2.1 ASTM Standards:2D2122 Test Method for Determining Dimensions of Ther-moplastic Pipe and FittingsD3517 Specification for “Fiberglass” (Glass-Fiber-Reinforced Thermosetting-Resin) Pressure PipeD3567 Practice for Determining Dimensions of “Fiberglass”(Glass-Fiber-Reinforced Therm
10、osetting Resin) Pipe andFittings3. Summary of Test Method3.1 This test method consists of loading a specimen tofailure, or a predetermined minimum level, in short-timeinterval by means of continuously increasing internalhydraulic-pressure while immersed in a controlled-temperatureenvironment.4. Sign
11、ificance and Use4.1 This test method establishes the short term hydraulicfailure pressure of thermoplastic pipe, tubing and fittings, andreinforced thermosetting pipe, and reinforced thermoplasticpipe. Data obtained by this test method are of use only inpredicting the behavior of pipe, tubing, and f
12、ittings underconditions of temperature, time, method of loading, and hoopstress similar to those used in the actual test. They are generallynot indicative of the long-term strength of thermoplastic orreinforced thermosetting resin pipe, tubing, and fittings, andreinforced thermoplastic pipe.4.2 Proc
13、urement specifications utilizing this test methodmay stipulate a minimum and maximum time for failure otherthan the 60 to 70 s listed in 9.1.3. Either the internal hydraulicpressure or the hoop stress may be listed in the requirements.NOTE 2Many thermoplastics give significantly different burststren
14、gths depending on the time to failure. For instance, significantdifferences have been observed between failure times of 65 and 85 s.1This test method is under the jurisdiction of ASTM Committee F17 on PlasticPiping Systems and is the direct responsibility of Subcommittee F17.40 on TestMethods.Curren
15、t edition approved Sept. 1, 2018. Published September 2018. Originallyapproved in 1962. Last previous edition approved in 2014 as D1599 141. DOI:10.1520/D1599-182For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book o
16、f ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international sta
17、ndard was developed in accordance with internationally recognized principles on standardization established in the Decision on Principles for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.14.3
18、This test method is also used as a short-term pressur-ization validation procedure, where the specimens are pressur-ized to a predetermined minimum pressure requirement.5. Failure5.1 Any instantaneous or rapid loss of pressure shall con-stitute failure.5.2 Any visible passage of fluid through the wa
19、ll of thespecimen shall constitute failure.5.3 Any loss of pressure that interrupts the continuous anduniform pressure increase, described in 9.1.3, shall constitutefailure.5.4 Leakage at the end closure or fracture of the specimen inthe immediate vicinity of the end closure shall be considered asan
20、 invalid test item, not a failure.6. Apparatus6.1 Constant-Temperature BathAwater bath or other fluidbath equipped so that uniform temperature is maintainedthroughout the bath. This may require agitation. If an air orother gaseous environment is used, provisions shall be madefor adequate circulation
21、. Unless otherwise stated, the tests shallbe conducted at 736 3.6 F (23 6 2 C). The tolerance onother test temperatures shall be 3.6 F (6 2 C). Fluid envi-ronments that chemically attack the specimens shall not beused unless this effect is being studied. In that case, the purposeof the test shall be
22、 included in the report.NOTE 3Reinforced thermosetting resin pipe and fittings may showincreasing failure pressures as temperature is raised above 73.4 F (23 C)in this test.6.2 Pressurizing SystemA device capable of applying anessentially continuously increasing internal hydraulic pressureto the tes
23、t specimen. Suggested equipment for this test mayinclude the following:6.2.1 Nitrogen Supply (Cylinder Gas) with a pressure regu-lator and hydraulic accumulator, or6.2.1.1 Pump, capable of applying essentially continuouslyincreasing internal hydraulic pressure to the test specimen.6.3 Pressure Indic
24、ating System:6.3.1 Pressure GaugesWhen used, mechanical pressuregauges shall have a precision within 1 % of full-scale deflec-tion with a maximum indicating hand.6.3.2 Pressure TransducersWhen used, pressure transduc-ers shall have a precision with 1% of full-scale deflection. Thesystem shall have t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD15992018STANDARDTESTMETHODFORRESISTANCETOSHORTTIMEHYDRAULICPRESSUREOFPLASTICPIPETUBINGANDFITTINGSPDF

链接地址:http://www.mydoc123.com/p-510120.html