ASTM D1555M-2008e1 Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane [Metric]《工业香烃类计量的体积和重量计算的标准试验方法》.pdf
《ASTM D1555M-2008e1 Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane [Metric]《工业香烃类计量的体积和重量计算的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1555M-2008e1 Standard Test Method for Calculation of Volume and Weight of Industrial Aromatic Hydrocarbons and Cyclohexane [Metric]《工业香烃类计量的体积和重量计算的标准试验方法》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1555M 081Standard Test Method forCalculation of Volume and Weight of Industrial AromaticHydrocarbons and Cyclohexane Metric1This standard is issued under the fixed designation D 1555M; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEThe units statements in 1.3 and 1.3.1 were corrected editorially in May 2009.1. Scope*1.1 This s
3、tandard is for use in calculating the weight andvolume of benzene, toluene, mixed xylenes, styrene, ortho-xylene, meta-xylene, para-xylene, cumene, ethylbenzene,148.9 to 176.7C and 176.7 to 204.4C aromatic hydrocarbons,and cyclohexane. A method is given for calculating the volumeat 15C and 20C from
4、an observed volume at tC. Table 1 liststhe density in grams per cubic centimetre at 15C and 20C forhigh purity chemicals.1.2 Calculated results shall be rounded off in accordancewith the rounding-off method of Practice E29.1.3 The values stated in SI units are to be regarded asstandard. No other uni
5、ts of measurement are included in thisstandard.1.3.1 A complete inch-pound unit companion standard hasbeen developed in Test Method D 1555.1.4 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to
6、 establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1217 Test Method for Density and Relative Density(Specific Gravity) of Liquids by Bingham PycnometerD 1555 Test Method for Calculat
7、ion of Volume and Weightof Industrial Aromatic Hydrocarbons and CyclohexaneD 3505 Test Method for Density or Relative Density ofPure Liquid ChemicalsD 4052 Test Method for Density and Relative Density ofLiquids by Digital Density MeterE29 Practice for Using Significant Digits in Test Data toDetermin
8、e Conformance with Specifications2.2 Other Documents:Patterson, J. B., and Morris, E. C., Metrologia, 31, 1994,pp. 277-288TRC Thermodynamic TablesHydrocarbons, NSRDS-NIST 75-121, Supplement No. 121, April 30, 20013. Significance and Use3.1 This test method is suitable for use in calculatingweights a
9、nd volumes of the products outlined in Section 1. Theinformation presented can be used for determining quantities ofthe above-stated aromatic hydrocarbons in tanks, shippingcontainers, etc.4. Basic Data4.1 Densities of pure materials at 15C and 20C are derivedfrom densities furnished by NSRDS-NIST 7
10、5-121 (NationalStandard Reference Data SeriesNational Institute of Stan-dards and Technology). Densities of impure materials shouldbe determined by actual measurement (see Section 7).4.2 The VCF (Volume Correction Factor) equations pro-vided below are derived from the Volume Correction imple-mentati
11、on procedures presented in Method D 1555 - 04a.4.3 The former VCF tables were based on data for com-pounds of the highest purity, but were reported to be usable formaterials in the ranges indicated in Table 2. The data support-ing this conclusion appears to be unavailable at the presenttime; however
12、 there is no reason to change this recommenda-tion. If, depending on the composition of the impurities, thereis reason to suspect that the VCF implementation procedurespresented below do not apply to a particular impure product, aseparate implementation procedure should be independentlydetermined. T
13、his may be done by measuring the density of arepresentative sample at different temperatures throughout theexpected working temperature range, regressing the data toobtain a temperature/density equation that best reproduces theobserved data, and then dividing the constants of thetemperature/density
14、equation by the calculated density at 15Cand 20C. Alternatively, if the composition has been quantified1This test method is under the jurisdiction of ASTM Committee D16 onAromatic Hydrocarbons and Related Chemicals and is the direct responsibility ofSubcommittee D16.01 on Benzene, Toluene, Xylenes,
15、Cyclohexane and TheirDerivatives.Current edition approved Feb. 1, 2008. Published March 2008. Originallyapproved in 1993. Last previous edition approved in 2004 as D 1555M 04a.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. Fo
16、r Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.one
17、can use the VCFs of each component (if available) tocalculate a weighted average density at different temperaturesand then process the data as mentioned above.5. Volume Correction Factor Implementation Procedure5.1 The following general equation is used to generate theVolume Correction Factors:VCF 5
18、a 1 b 1.8t132! 1 c 1.8t132!21 d 1.8t132!31e 1.8t132!4!/VCFXX(1)where:t = temperature in C,VCFXX5 VCF59For VCF68F, andconstants a through e and VCFXXare specific to eachcompound (obtained from Method D 1555 04a and presentedin Table 3).5.2 Temperature may be entered in tenths of a degreeCentigrade.5.
19、3 The final result is rounded to 5 places past the decimal.No intermediate rounding or truncation should be done.5.4 The equations are valid for liquid product up to 60C(65.5C for p-xylene).5.5 This implementation procedure replaces the printedtables of previous editions of this Method for determini
20、ngVCFs. The implementation procedure is the Standard, notthe printed tables. However, a printout from the implemen-tation procedure is provided in 0.5C increments for the usersconvenience (Tables 4 and 5).6. Use of the Implementation Procedure6.1 Volume Reduction to 15CEnter the appropriate equa-tio
21、n with the temperature to the nearest 0.1 degree CentigradeTABLE 1 Physical PropertiesProductFreezingPointCBoilingPointCDensity in Vacuoat 15Cg/ccA,B,CDensity in Airat 15Cg/ccDDensity in Vacuoat 20Cg/ccC,E,FDensity in Airat 20Cg/ccDBenzene 5.6 80.1 0.88431 0.88324 0.87908 0.87801Cumene -96.1 152.4 0
22、.86586 0.86479 0.86160 0.86053Cyclohexane 6.6 80.7 0.78317 0.78209 0.77849 0.77741Ethylbenzene -95.0 136.2 0.87126 0.87019 0.86685 0.86578Styrene -30.6 145.2 0.91028 0.90922 0.90586 0.90480Toluene -95.0 110.6 0.87147 0.87040 0.86686 0.86579m-Xylene -47.9 139.1 0.86831 0.86724 0.86408 0.86301o-Xylene
23、 -25.2 144.4 0.88387 0.88280 0.87968 0.87861p-Xylene 13.3 138.3 0.86503 0.86396 0.86076 0.85969AObtained from Method D 1555 04a by multiplying the chemicals 60F density by the volume correction factor for 59F.BSpecific Gravity at 15C is not presented in this table as it is unnecessary to this standa
24、rd. If needed, divide 15C density in g/cc by 0.999102 g/cc. See AppendixX1.Cg/cc can be converted to kg/1000L or kg/m3by multiplying by 1000.DProduced using g/cc = (Density 1.00014992597 0.00119940779543) and rounding to 5 decimal places. See Appendix X2.EObtained from Method D 1555 - 04a by multipl
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD1555M2008E1STANDARDTESTMETHODFORCALCULATIONOFVOLUMEANDWEIGHTOFINDUSTRIALAROMATICHYDROCARBONSANDCYCLOHEXANEMETRIC

链接地址:http://www.mydoc123.com/p-510023.html