ASTM D1429-2008 Standard Test Methods for Specific Gravity of Water and Brine《水和盐水的比重的标准试验方法》.pdf
《ASTM D1429-2008 Standard Test Methods for Specific Gravity of Water and Brine《水和盐水的比重的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1429-2008 Standard Test Methods for Specific Gravity of Water and Brine《水和盐水的比重的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1429 08Standard Test Methods forSpecific Gravity of Water and Brine1This standard is issued under the fixed designation D 1429; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in p
2、arentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 These test methods cover the determination of thespecific gravity of water and brine free of separable oil, asfollows:SectionsTest Method APycnome
3、ter 7 to 11, 21Test Method BBalance 12 to 16, 21Test Method CErlenmeyer Flask 17 to 21Test Method DHydrometer 22 to 271.2 Test Methods A and B are applicable to clear waters orthose containing only a moderate amount of particulate matter.Test Method B is preferred for samples of sea water or brinesa
4、nd is more sensitive than Test Method D which has the samegeneral application. Test Method C is intended for samples ofwater containing mud or sludge.1.3 It is the users responsibility to ensure the validity ofthese test methods for waters of untested matrices.1.4 The test method was tested at 22C o
5、ver a range, showninTables 1-4, of 1.0252 through 1.2299; all data were correctedto 15.6C (60F).1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health p
6、ractices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D 1066 Practice for Sampling SteamD 1129 Terminology Relating to WaterD 1193 Specification for Reagent WaterD 2777 Practice for Determination of Precision and Bias ofApplicable
7、 Test Methods of Committee D19 on WaterD 3370 Practices for Sampling Water from Closed ConduitsD 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE1 Specification for ASTM Liquid-in-Glass Thermometers3. Terminology3.1 Definitions:3.1.1 brinewater th
8、at contains dissolved matter at anapproximate concentration of more than 30 000 mg/L.3.1.2 For definitions of terms used in these test methods,refer to Terminology D 1129.4. Significance and Use4.1 Specific gravity is an important property of fluids beingrelated to density and viscosity. Knowing the
9、 specific gravitywill allow determination of a fluids characteristics comparedto a standard, usually water, at a specified temperature. Thiswill allow the user to determine if the test fluid will be heavieror lighter than the standard fluid.5. Reagents5.1 Purity of WaterUnless otherwise indicated, r
10、eferenceto water shall be understood to mean reagent water conformingto Specification D 1193, Type I. Other reagent water types maybe used provided it is first ascertained that the water is ofsufficiently high purity to permit its use without adverselyaffecting the precision and bias of the test met
11、hod. Type IIIwater was specified at the time of round robin testing of thistest method.6. Sampling6.1 Collect the samples in accordance with PracticesD 3370 and Practice D 1066.6.2 In view of the lack of a standard test method forsampling mud or sludge, no instructions are given for samplingthis typ
12、e of material.TEST METHOD APYCNOMETER7. Summary of Test Method7.1 The sample is introduced into a pycnometer, stabilizedat the desired temperature, and weighed. The specific gravity iscalculated from this weight and the previously determined1These test methods are under the jurisdiction of ASTM Comm
13、ittee D19 onWater and are the direct responsibility of Subcommittee D19.05 on InorganicConstituents in Water.Current edition approved Nov. 15, 2008. Published November 2008. Originallyapproved in 1956. Last previous edition approved in 2003 as D 1429 2003.2For referenced ASTM standards, visit the AS
14、TM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, Unit
15、ed States.weight of reagent water that is required to fill the pycnometerat the same temperature.8. Apparatus8.1 BathConstant-temperature bath designed to maintaina temperature of 15.6 6 1C (60 6 1.8F). If any othertemperature must be used due to local conditions, appropriatecorrections shall be mad
16、e.8.2 PycnometerCylindrical or conical glass vessel care-fully ground to receive an accurately fitting 24/12 standardtaper glass stopper provided with a hole approximately 1.0 to2.0 mm in diameter, centrally located in reference to thevertical axis.The top surface of the stopper shall be smooth ands
17、ubstantially plane, and the lower surface shall be concave inorder to allow all air to escape through the bore. The height ofthe concave section shall be approximately 5 mm at the center.The stoppered pycnometer shall have a capacity of about 24 to30 mL, and shall weigh not more than 40 g. Suitable
18、pycnom-eters are shown in Fig. 1.8.3 ThermometerAnASTM Gravity Thermometer havinga range from 20 to + 102C or 5 to + 215F, as specified,and conforming to the requirements for Thermometer 12C or12F, respectively, as prescribed in Specification E1.9. Procedure9.1 Weigh a clean, dry, calibrated pycnome
19、ter, completewith stopper, on an analytical balance, and record this weightto the nearest 0.1 mg, as P.9.2 Remove the stopper and fill the pycnometer with re-cently boiled reagent water that has been cooled to roomtemperature, to within several millimetres of the top. Removethe air bubbles. Immerse
20、the unstoppered pycnometer up to theneck in a constant-temperature bath maintained at 15.6 6 1C(60 6 1.8F). Allow the pycnometer to remain in the bath fora period of time sufficient to establish temperature equilibrium.Twenty minutes is usually sufficient.9.3 After temperature equilibrium has been e
21、stablished, andbefore removing from the bath, firmly insert the stopper andremove the excess water from the top of the stopper, takingcare to leave the capillary filled. Remove the stopperedpycnometer from the bath and wipe it dry. Immediately weighthe pycnometer, and record this weight to the neare
22、st 0.1 mg,as W.9.4 Empty the reagent water from the pycnometer and dry,or rinse with the sample to be tested.9.5 Using the sample to be tested, repeat the procedure inaccordance with 9.2 and 9.3, recording the weight of thepycnometer containing the sample under test as S.10. Calculation10.1 Calculat
23、e the specific gravity of the sample as follows:Specific gravity 5 S2P!/W2P!where:P = weight of the empty pycnometer,S = weight of the pycnometer and contained sample, andW = weight of the pycnometer and contained reagentwater.FIG. 1 Suitable PycnometersTABLE 1 Determination of Bias, Pycnometer Meth
24、odCalculated SpecificGravitySpecific GravityExperimentallyDetermined6 %BiasStatisticallySignificant(95 % ConfidenceLevel)1.0247 1.0262 0.049 yes1.0648 1.0665 + 0.16 yes1.1100 1.1119 + 0.17 yes1.2299 1.2235 0.52 yesTABLE 2 Determination of Bias, Balance MethodCalculated SpecificGravitySpecific Gravit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD14292008STANDARDTESTMETHODSFORSPECIFICGRAVITYOFWATERANDBRINE 盐水 比重 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509792.html