1、Designation: D 1426 08Standard Test Methods forAmmonia Nitrogen In Water1This standard is issued under the fixed designation D 1426; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses
2、 indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 These test methods cover the determination of ammonianitrogen, exclusive of
3、 organic nitrogen, in water. Two testmethods are included as follows:SectionsTest Method ADirect Nesslerization 7 to 15Test Method BIon Selective Electrode 16 to 241.2 Test Method A is used for the routine determination ofammonia in steam condensates and demineralizer effluents.1.3 Test Method B is
4、applicable to the determination ofammonia nitrogen in the range from 0.5 to 1000 mg NH3N/Ldirectly in reagent and effluent waters. Higher concentrationscan be determined following dilution. The reported lowerrange is based on multiple-operator precision. Lower limitshave been obtained by two of the
5、twelve laboratories partici-pating in the round robin.1.4 Both test methods A and B are applicable to surface andindustrial waters and wastewaters following distillation. Thetest method for distillation given inAppendix X1 has been usedin the past to meet requirements for predistillation of samplesb
6、eing analyzed for ammonia.1.5 The values stated in SI units are to be regarded asstandard. No other units of measurement are included in thisstandard.1.6 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this
7、standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.7 The distillation method now appears as Appendix X1and is provided as nonmandatory information only. The auto-mated colorimetric phenate method has been discontin
8、ued.2. Referenced Documents2.1 ASTM Standards:2D 1066 Practice for Sampling SteamD 1129 Terminology Relating to WaterD 1192 Guide for Equipment for Sampling Water andSteam in Closed Conduits3D 1193 Specification for Reagent WaterD 2777 Practice for Determination of Precision and Bias ofApplicable Te
9、st Methods of Committee D19 on WaterD 3370 Practices for Sampling Water from Closed ConduitsD 5810 Guide for Spiking into Aqueous SamplesD 5847 Practice for Writing Quality Control Specificationsfor Standard Test Methods for Water AnalysisE60 Practice for Analysis of Metals, Ores, and RelatedMateria
10、ls by Molecular Absorption SpectrometryE 275 Practice for Describing and Measuring Performanceof Ultraviolet, Visible, and Near-Infrared Spectrophotom-eters2.2 APHA Standard4:Standard Methods for the Examination of Water and WasteWater3. Terminology3.1 DefinitionsFor definitions of terms used in the
11、se testmethods, refer to Terminology D 1129.4. Significance and Use4.1 Nitrogen is a nutrient in the environment and is neces-sary to sustain growth of most organisms. It exists in severalforms such as nitrate, nitrite, organic nitrogen such as proteinsor amino acids, and ammonia.4.2 Ammonia is a co
12、lorless, gaseous compound with a sharpdistinctive odor. It is highly soluble in water where it exists ina molecular form associated with water and in an ionized form1These test methods are under the jurisdiction of ASTM Committee D19 onWater and are the direct responsibility of Subcommittee D19.05 o
13、n InorganicConstituents in Water.Current edition approved Aug. 15, 2008. Published September 2008. Originallyapproved in 1956. Last previous edition approved in 2003 as D 1426 03.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org.
14、 For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Withdrawn.4Available from American Public Health Association, 800 I St. N.W., Washing-ton, DC 20001, http:/www.apha.org.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box
15、C700, West Conshohocken, PA 19428-2959, United States.as NH4+. The extent of association or ionization is dependenton the temperature and pH. It may also be toxic to aquatic life.The extent of toxicity is dependent upon species and extent ofdissociation.5Ammonia may occur in water as a product ofana
16、erobic decomposition of nitrogen containing compounds orfrom waste streams containing ammonia.5. Purity of Reagents5.1 Reagent grade chemicals shall be used in all tests.Unless otherwise indicated, it is intended that all reagents shallconform to the specifications of the Committee on AnalyticalReag
17、ents of the American Chemical Society, where suchspecifications are available.6Other grades may be used, pro-vided it is first ascertained that the reagent is of sufficientlyhigh purity to permit its use without lessening the accuracy ofthe determination.5.2 Unless otherwise indicated, references to
18、 water shall beunderstood to mean reagent water conforming to SpecificationD 1193, Type I. In addition, this water shall be free of ammonianitrogen. Such water is best prepared by the passage of distilledwater through an ion-exchange resin. These resins should alsobe selected so that organic compoun
19、ds which might subse-quently interfere with the ammonia determination will beremoved. Regeneration of the ion-exchange materials shouldbe carried out in accordance with the instructions of themanufacturer.6. Sampling6.1 Collect the sample in accordance with Practice D 1066,Specification D 1192, and
20、Practices D 3370, as applicable.6.2 Preserve the samples by the addition of 1 mL ofconcentrated sulfuric acid per litre and store at 4C. The pHshould be 2.0 or less. Analyze the samples within 24 h ofsampling. Do not use mercuric chloride as a preservative.TEST METHOD ADIRECT NESSLERIZATION7. Scope7
21、.1 This test method is suitable for the rapid routinedetermination of ammonia nitrogen in steam condensates anddemineralized water. See Appendix X1 for the distillation testmethod.8. Summary of Test Method8.1 A sample aliquot is Nesslerized directly and the ammo-nia content determined colorimetrical
22、ly.9. Interferences9.1 Glycine, urea, glutamic acid, cyanates, and acetamidehydrolyze very slowly in solution on standing, but, of these,only urea and cyanates will hydrolyze on distillation at a pH of9.5. Glycine, hydrazine, and some amines will react withNesslers reagent to give the characteristic
23、 yellow color in thetime required for the test. Similarly, volatile alkaline com-pounds such as hydrazine and the amines will influencetitrimetric results. Some organic compounds such as ketones,aldehydes, alcohols, and some amines may cause an off coloron Nesslerization. Some of these, such as form
24、aldehyde maybe eliminated by boiling off at a low pH prior to Nesslerization.Residual chlorine must be removed prior to the ammoniadetermination by pretreatment of the sample.9.2 Turbid samples may be clarified with ZnSO4and NaOHsolution; the precipitated Zn(OH)2is filtered off, discarding thefirst
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD14262008STANDARDTESTMETHODSFORAMMONIANITROGENINWATER 水中 氨态氮 标准 试验 方法 PDF

链接地址:http://www.mydoc123.com/p-509789.html