ASTM D1294-2005 Standard Test Method for Tensile Strength and Breaking Tenacity of Wool Fiber Bundles 1-in (25 4-mm) Gage Length《1英寸(25 4毫米)规准长度羊毛纤维束的拉伸强度和断裂强度的标准试验方法》.pdf
《ASTM D1294-2005 Standard Test Method for Tensile Strength and Breaking Tenacity of Wool Fiber Bundles 1-in (25 4-mm) Gage Length《1英寸(25 4毫米)规准长度羊毛纤维束的拉伸强度和断裂强度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1294-2005 Standard Test Method for Tensile Strength and Breaking Tenacity of Wool Fiber Bundles 1-in (25 4-mm) Gage Length《1英寸(25 4毫米)规准长度羊毛纤维束的拉伸强度和断裂强度的标准试验方法》.pdf(6页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1294 05Standard Test Method forTensile Strength and Breaking Tenacity of Wool FiberBundles 1-in. (25.4-mm) Gage Length1This standard is issued under the fixed designation D 1294; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、 revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the break-ing force (or load) and estimation of t
3、he tensile strength andtenacity of wool fiber bundles with a 1-in. (25.4-mm) gagelength. A procedure for preparation of the fiber bundle isincluded.1.2 The values stated in inch-pound units are to be regardedas standard; the values in SI units are provided for informationonly. Because the instrument
4、 is calibrated in inch-pound units,inch-pound units are shown first, contrary to Committee D13policy.NOTE 1For other methods of measuring breaking tenacity of fiberbundles, refer to Test Methods D 1445 and D 2524.NOTE 2This test method can be used for other fibers that lendthemselves to the same kin
5、d of preparation but the difference in densitymust be taken into account when calculating the tensile strength. It is notnecessary to know or correct for the density of a fiber when calculatingbreaking tenacity.1.3 This standard does not purport to address all of thesafety concerns, if any, associat
6、ed with its use. It is theresponsibiltiy of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2D76 Specification for Tensile Testing Machines for TextilesD
7、123 Terminology Relating to TextilesD 1445 Test Method for Breaking Strength and Elongationof Cotton Fibers (Flat Bundle Method)D 1776 Practice for Conditioning and Testing TextilesD 2524 Test Method for Breaking Tenacity of Wool Fibers,Flat Bundle Method18-in. (3.2-mm) Gage LengthD 2525 Practice fo
8、r Sampling Wool for MoistureD 4845 Terminology for Wool3. Terminology3.1 For all terminology related to Wool and Wool Felt,D13.13, refer to Terminology D 4845.3.1.1 The following terms are relevant to this standard: gagelength, recycled wool tenacity, wool.3.2 For all other terminology related to te
9、xtiles see Termi-nology D 123.4. Summary of Test Method4.1 The strength determination is based on the load requiredto break a bundle of fibers which had been parallelized andheld under uniform tension with masking tape. A 1-in. (25.4-mm) spacing between the tapes (and clamps at the zero setting)make
10、s possible the cutting and weighing of this amount of fiberfor use in calculating the strength expressed as breakingtenacity in grams-force per tex or tensile strength in pounds-force per square inch.5. Significance and Use5.1 Test Method D 1294 for the determination of tensilestrength may be used f
11、or the acceptance testing of commercialshipments of wool, but caution is advised since techniciansmay fail to get good agreement between results. Comparativetests as directed in 5.1.1 may be advisable.5.1.1 If there are differences of practical significance be-tween reported test results for two lab
12、oratories (or more),comparative test should be performed to determine if there is astatistical bias between them, using competent statistical assis-tance. As a minimum, use the samples for such a comparativetest that are as homogenous as possible, drawn from the samelot of material as the samples th
13、at resulted in disparate resultsduring initial testing and randomly assigned in equal numbersto each laboratory. The test results from the laboratoriesinvolved should be compared using a statistical test forunpaired data, a probability level chosen prior to the testingseries. If bias is found, eithe
14、r its cause must be found andcorrected, or future test results for that material must beadjusted in consideration of the known bias.1This test method is under the jurisdiction ofASTM Committee D13 on Textilesand is the direct responsibility of Subcommittee D13.13 on Wool and Wool Felt.Current editio
15、n approved April 1, 2005. Published May 2005. Originallyapproved in 1953 . Last previous edition approved in 2001 as D 1294 95a(2001).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume info
16、rmation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2 This test method is useful in studying the relationshipbetween fiber strength and product quality; results s
17、hould beconsidered comparative rather than fundamental since thestrength found will be lower than the sum of the strengths ofthe individual fibers present due to slight differences intensioning.5.3 Elongation may be obtained also but the accuracy ofelongation measurements is limited and their determ
18、ination is,therefore, not included as a formal part of this test method.5.4 The basic differences between the procedures employedin this test method and those of Test Method D 2524 are in thegage lengths employed and the methods of clamping. In TestMethod D 2524, specific clamps are required whereas
19、 in TestMethod D 1294, any conventional clamps may be used. Re-sults for breaking load determined by Test Method D 2524average 30 % higher than those obtained by Test MethodD 1294.6. Apparatus and Materials6.1 Comb, fine, sharp.36.2 Analytical Balance, with a sensitivity of 0.0001 g.6.3 Tensile Test
20、ing Machine, a CRE or CRT Type about50-lb (22-kg) capacity machine as prescribed in SpecificationD76, capable of operating the moving clamp at a uniformspeed of 10.0 6 0.5 in./min (250 6 12 mm/min). If a CRLtypemachine is used, it should be capable of operating at a rate ofloading of 1 kgf/s (10 N/s
21、). In no case shall the working rangebe outside the limits recommended by the manufacturer.NOTE 3There may be no overall correlation between the resultsobtained with the CRE, CRT, or CRL type testing machines. Conse-quently, these three machines cannot be used interchangeably.6.4 Metal Plates, 2 by
22、1-in. (50.8 by 25.4-mm) with onerubber-covered surface. The plates should be rigid, flat, andapproximately 0.1 in. (2.5 mm) thick with one rubber faceapproximately 0.06 in. (1.5 mm) thick (Note 4). Two plates arerequired to prepare a bundle for testing.NOTE 4These plates can be made by gluing rubber
23、 sheeting approxi-mately 0.06 in. (1.5 mm) thick to the face of the plate.6.5 Hand Vise,3preferably of the spring-type.6.6 Masking Tape, 2-in. (50-mm) wide, heavy.7. Sampling7.1 Division into LotsTreat a single shipment of a singlefiber type as a lot.7.2 Lot SampleAs a lot sample for acceptance test
24、ing,take at random the number of shipping containers directed inan applicable material specification or other agreement be-tween the purchaser and the supplier, such as an agreement touse Practice D 2525. Consider shipping containers to be theprimary sampling units.7.3 Laboratory SampleFor acceptanc
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD12942005STANDARDTESTMETHODFORTENSILESTRENGTHANDBREAKINGTENACITYOFWOOLFIBERBUNDLES1IN254MMGAGELENGTH1

链接地址:http://www.mydoc123.com/p-509592.html