ASTM D1243-1995(2000)e1 Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers《氯乙烯聚合物的稀溶液粘度的标准试验方法》.pdf
《ASTM D1243-1995(2000)e1 Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers《氯乙烯聚合物的稀溶液粘度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM D1243-1995(2000)e1 Standard Test Method for Dilute Solution Viscosity of Vinyl Chloride Polymers《氯乙烯聚合物的稀溶液粘度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: D 1243 95 (Reapproved 2000)e1Standard Test Method forDilute Solution Viscosity of Vinyl Chloride Polymers1This standard is issued under the fixed designation D 1243; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.e1NOTEReference to ISO 1628-2 was corrected editorially in March 2000.1. Scope1.1 This test method covers the determinati
3、on of the dilutesolution viscosity of vinyl chloride polymers in cyclohex-anone. The viscosity is expressed in terms of inherent viscosity(logarithmic viscosity number). The test method is limited tothose materials that give clear, uniform solutions at the testdilution.NOTE 1Other expressions for vi
4、scosity may be used as described inthe Appendix, but any change from the test method as specified shall bestated in the report.1.2 The values stated in SI units are to be regarded as thestandard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use.
5、 It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.NOTE 2Although this test method and ISO 1628-2-1998 differ inapproach or detail, data obtained by either are technically
6、 equivalent.2. Referenced Documents2.1 ASTM Standards:D 445 Test Method for Kinematic Viscosity of Transparentand Opaque Liquids (and the Calculation of DynamicViscosity)2D 883 Terminology Relating to Plastics2D 1600 Terminology for Abbreviated Terms Relating toPlastics3D 1755 Specification for Poly
7、(Vinyl Chloride) Resins3D 2857 Test Method for Dilute Solution Viscosity of Poly-mers4E 77 Method for Verification and Calibration of Liquid-in-Glass Thermometers52.2 ISO Standard:ISO 1628-2-1998 Determination of Viscosity Number andLimiting Viscosity NumberPart 2: Poly(Vinyl Chloride)Resins62.3 Nat
8、ional Institute of Standards and Technology Circu-lar:7C-434 Testing of Glass Volumetric Apparatus3. Terminology3.1 Definitions: Definitions are in accordance with Termi-nology D 883 and Terminology D 1600, unless otherwiseindicated.4. Summary of Test Method4.1 A sample of resin is dissolved in cycl
9、ohexanone to makea solution of specified concentration. Inherent viscosity (loga-rithmic viscosity number) is calculated from the measured flowtimes of the solvent and of the polymer solution.NOTE 3For additional information, refer to Test Method D 445 andTest Method D 2857 for Dilute Solution Visco
10、sity of Polymers.35. Significance and Use5.1 Dilute solution viscosity values for vinyl chloride poly-mers are related to the average molecular size of that portion ofthe polymer that dissolves in the solvent.6. Apparatus6.1 Transfer Pipets.6.2 Volumetric Flasks, 100-mL, glass-stoppered, in accor-da
11、nce with National Institute of Standards and TechnologyCircular C-434.6.3 Viscometer, Ubbelohde Series U-1 or Cannon-Ubbelohde No. 75.1This test method is under the jurisdiction of ASTM Committee D20 on Plasticsand is the direct responsibility of Subcommittee D20.15 on Thermoplastic Materials(Sectio
12、n D20.15.07).Current edition approved March 15, 1995. Published May 1995. Originallypublished as D 1243 52 T. Last previous edition D 1243 79 (1990)e1.This edition contains changes in Sections 1 and 2 to include an ISO equivalencystatement.2Annual Book of ASTM Standards, Vols 05.01 and 10.03.3Annual
13、 Book of ASTM Standards, Vol 08.01.4Annual Book of ASTM Standards, Vol 08.02.5Annual Book of ASTM Standards, Vol 14.03.6Available from American National Standards Institute, 11 W. 42nd St., 13thFloor, New York, NY 10036.7Available from National Institute of Standards and Technology, U. S. Dept. ofCo
14、mmerce, Washington, DC 20234.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.6.4 Water Bath,at306 0.5C, controlled to within 60.01C.6.5 Timer, as specified in Test Method D 445, graduated indivisions of 0.1 s or less.6.6 Filter Funne
15、l, fritted-glass.86.7 Thermometer, standard, in accordance with MethodE 77.7. Materials7.1 SolventCyclohexanone, analytical reagent grade orlaboratory-distilled technical grade, boiling between 155 and156C at 760 mm Hg has been found acceptable if stored in aclosed container.8. Procedure8.1 Dissolve
16、 duplicates of resin as follows: Weigh 0.260.002 g of the sample (moisture content below 0.1 %) andtransfer it to a 100-mL glass-stoppered volumetric flask. Takecare to transfer all of the weighed resin into the flask. As analternative method, the resin (0.26 0.002 g) may be weigheddirectly into a t
17、ared, 100-mL glass-stoppered volumetric flask.8.2 Add 50 to 70 mL of cyclohexanone to the flask, takingcare to wet the resin so that lumps do not form.8.3 Heat the flask at 85 6 10C until the resin is dissolved.Occasional shaking will reduce the time required for solution.Heating should not exceed 1
18、2 h and should preferably be lessto minimize degradation. If any gel-like particles can be seen,prepare a new solution.8.4 Cool the solution to the test temperature by immersingflask in the 30C bath for a minimum time of 30 min and adjustto a solution volume of 100 mL. Filter through a fritted-glass
19、filter directly into the viscometer.8.5 Measure at 30C the flow time of the prepared solution(8.4) and of the pure solvent (aged at 85 6 10C) in theviscometer. Allow 10 min for the viscometer to come totemperature equilibrium after placing it in the water bath. Theflow time of the solution or the so
20、lvent should be within 0.1 %on repeat runs on the same filling.NOTE 4Keep the Ubbelohde viscometer clean when not in use.Acetone may be used as a cleaning flush. The viscometer may be storedfilled with pure solvent or it may be stored dry.9. Calculation9.1 Calculate the relative and inherent viscosi
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD124319952000E1STANDARDTESTMETHODFORDILUTESOLUTIONVISCOSITYOFVINYLCHLORIDEPOLYMERS 氯乙烯 聚合物 溶液 粘度

链接地址:http://www.mydoc123.com/p-509506.html