1、Designation: D1049 98 (Reapproved 2010)Standard Specification forRubber Insulating Covers1This standard is issued under the fixed designation D1049; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification covers acceptance testing of rubberinsul
3、ating covers for use as portable protective devices forprotection of workers from accidental contact with live elec-trical conductors, apparatus, or circuits. It includes insulatorhoods, dead-end protectors, line hose connectors, cable endcovers, and miscellaneous covers. The electrical, physical, a
4、ndchemical requirements of this specification shall apply also toany new or modified styles of covers that may be developed forspecific purposes.1.2 Three types of covers, differing in chemical and physicalcharacteristics, are provided, and are designated as Type I,non-resistant to ozone, and Type I
5、I and Type III, resistant toozone.1.3 Five classes of covers, differing in electrical character-istics, are provided, and are designated as Class 0, Class 1,Class 2, Class 3, and Class 4.1.4 Five styles of covers, differing in design characteristics,are provided, and are designated as Style A, Style
6、 B, Style C,Style D, and Style E.NOTE 1Because of the use requirements some covers are semi-rigidand others flexible.The flexible devices should remain suitably flexible forapplication and removal through normal temperatures of 29 to 54.5C(20 to 130F).1.5 This standard does not purport to address al
7、l of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. See 18.2.2. Referenced Documents2.1 ASTM Standards:2D297 Test
8、Methods for Rubber ProductsChemicalAnaly-sisD412 Test Methods for Vulcanized Rubber and Thermo-plastic ElastomersTensionD573 Test Method for RubberDeterioration in an AirOven3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 breakdownthe electrical discharge or arc occurringbetwe
9、en the electrodes and through the equipment being tested.3.1.2 flashoverthe electrical discharge or arc occurringbetween electrodes and over or around, but not through, theequipment being tested.3.1.3 ozonea very active form of oxygen that may beproduced by corona, arcing, or ultraviolet rays.3.1.4
10、ozone cutting and checkingthe cutting action pro-duced by ozone on rubber under mechanical stress into a seriesof interlacing cracks.3.1.5 rubbera generic term that includes elastomers andelastomeric compounds, regardless of origin.3.1.6 user as used in 4.3.1, the entity employing theactual worker(s
11、) using the equipment; if no separate employer,then the individual.3.1.7 voltage, maximum usethe ac voltage (rms) rating ofthe protective equipment that designates the maximum nominaldesign voltage of the energized system that may be safelyworked. The nominal design voltage is equal to the phase top
12、hase voltage on multiphase circuits.3.1.7.1 DiscussionIf there is no multiphase exposure in asystem area and the voltage exposure is limited to phase(polarity on dc systems) to ground potential, the phase (polarityon dc systems) to ground potential shall be considered to be thenominal design voltage
13、. If electrical equipment and devices areinsulated, or isolated, or both, such that the multiphase expo-sure on a grounded wye circuit is removed, then the nominaldesign voltage may be considered as the phase-to-groundvoltage on that circuit.3.1.8 voltage, nominal designa nominal value consistentwit
14、h the latest revision on ANSI C84.1, assigned to the circuitor system for the purpose of conveniently designating itsvoltage class.1This specification is under the jurisdiction of ASTM Committee F18 onElectrical Protective Equipment for Workers and is the direct responsibility ofSubcommittee F18.25
15、on Insulating Cover-Up Equipment. This standard replacesANSI Standard J6.2, which is no longer available.Current edition approved Oct. 1, 2010. Published November 2010. Originallypublished in 1949 as D1049 49 T. Last previous edition approved in 2002 asD1049 98 (2002)e1. DOI: 10.1520/D1049-98R10.2Fo
16、r referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C70
17、0, West Conshohocken, PA 19428-2959, United States.4. Significance and Use4.1 This specification covers the minimum electrical,chemical, and physical properties guaranteed by the manufac-turer and the detailed procedures by which such properties areto be determined. The purchaser may at his option p
18、erform orhave performed any of these tests in order to verify theguarantee. Claims for failure to meet the specification aresubject to verification by the manufacturer.4.2 Insulating covers are used for personal protection;therefore, when authorizing their use, a margin of safety shallbe provided be
19、tween the maximum voltage at which they areused and the proof-test voltage at which they are tested. Therelationship between proof-test voltage and the maximumvoltage at which insulating covers shall be used is shown inTable 1.4.3 Work practices vary from user to user, depending uponmany factors. Th
20、ese may include, but are not limited to,operating system voltages, construction design, work proce-dures and techniques, weather conditions, and so forth. There-fore, except for the restrictions set forth in this specificationbecause of design limitations, the use and maintenance of thisequipment is
21、 beyond the scope of this specification.4.3.1 It is common practice and the responsibility of the userof this type of protective equipment to prepare completeinstructions and regulations to govern the correct and safe useof such equipment.5. Classification5.1 Covers included under this specification
22、 shall be desig-nated as Type I, Type II, or Type III; Class 0, Class 1, Class 2,Class 3, or Class 4; StyleA, Style B, Style C, Style D, or StyleE.5.1.1 Type I, non-resistant to ozone, made from a high-gradecis-1,4-polyisoprene rubber compound of natural or syntheticorigin, properly vulcanized.5.1.2
23、 Type II, ozone resistant, made of any elastomer orcombination of elastomeric compounds.5.1.3 Type III, ozone-resistant, made of any combination ofelastomer and thermoplastic polymer, elastic in nature.5.1.4 ClassThe class designation shall be based on theelectrical properties and design characteris
24、tics as shown inTable 2 or Table 3.5.1.5 StyleThe style designation shall describe the item,size, and device or apparatus covered, protected, or connected.5.1.5.1 Style A designates insulator hoods.5.1.5.2 Style B designates dead end protectors.5.1.5.3 Style C designates line hose connectors.5.1.5.4
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMD104919982010STANDARDSPECIFICATIONFORRUBBERINSULATINGCOVERS 橡胶 绝缘 封盖物 标准规范 PDF

链接地址:http://www.mydoc123.com/p-509170.html