ASTM C958-1992(2007) Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation《用重力沉积的X射线监测器测定矾土或石英的粒度分布的试验方法》.pdf
《ASTM C958-1992(2007) Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation《用重力沉积的X射线监测器测定矾土或石英的粒度分布的试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C958-1992(2007) Standard Test Method for Particle Size Distribution of Alumina or Quartz by X-Ray Monitoring of Gravity Sedimentation《用重力沉积的X射线监测器测定矾土或石英的粒度分布的试验方法》.pdf(2页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 958 92 (Reapproved 2007)Standard Test Method forParticle Size Distribution of Alumina or Quartz by X-RayMonitoring of Gravity Sedimentation1This standard is issued under the fixed designation C 958; the number immediately following the designation indicates the year oforiginal adoptio
2、n or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of the particlesize distribution
3、 of alumina or quartz powders in the rangefrom 0.5 to 50 m and having a median particle diameter from2.5 to 10 m using a sedimentation method. This test methodis one of several found valuable for the measurement ofparticle size. Instruments used for this test method employ aconstant intensity X-ray
4、beam that is passed through a sedi-menting dispersion of particles.1.2 The values stated in SI units are to be regarded as thestandard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It
5、 is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use. For specific hazardstatements, see Section 7.2. Referenced Documents2.1 ASTM Standards:2C 242 Terminology of Ceramic White
6、wares and RelatedProductsE 177 Practice for Use of the Terms Precision and Bias inASTM Test MethodsE 691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 For definitions of terms used in this test method, refer toTerminology C 242.4. Summar
7、y of Test Method4.1 An aqueous homogeneous dispersion of the specimen ispermitted to settle in a cell. The decrease in particle concen-tration over a programmed settling distance is monitored by anX-ray beam passing through the sedimenting dispersion to adetector. The specimen concentration at any g
8、iven sedimenta-tion distance is inversely proportional to the X-ray flux and theequivalent diameter (spherical) is calculated from Stokes law.NOTE 1Refer to Terminology C 242. Most equipment manufacturersrefer to this as the equivalent spherical diameter.5. Apparatus5.1 X-Ray Sedimentation Apparatus
9、.5.2 Ultrasonic Probe or BathAn ultrasonic probe ap-proximately 13-mm (12-in.) in diameter and approximately 50to 100 W or an ultrasonic bath of approximately 0.3 W/cm2(2W/in.2).6. Reagents6.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it is inte
10、nded thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused, provided it is first ascertained that the reagent is ofsufficiently high purity to permit its use with
11、out lessening theaccuracy of the determination.6.2 Distilled or Deionized Water.6.3 Dispersing LiquidDissolve 1.0 g/L of reagent gradesodium hexametaphosphate in distilled or deionized water.Discard any remaining solution after six weeks from date ofpreparation.1This test method is under the jurisdi
12、ction ofASTM Committee C21 on CeramicWhitewares and Related Products and is the direct responsibility of SubcommitteeC21.04 on Raw Materials.Current edition approved May 1, 2007. Published June 2007. Originallyapproved in 1992. Last previous edition approved in 2000 as C 95892(2000)2For referenced A
13、STM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Reagent Chemicals, American Chemical Society Specifications, AmericanChemical
14、 Society, Washington, DC. For suggestions on the testing of reagents notlisted by the American Chemical Society, see Analar Standards for LaboratoryChemicals, BDH Ltd., Poole, Dorset, U.K., and the United States Pharmacopeiaand National Formulary, U.S. Pharmaceutical Convention, Inc. (USPC), Rockvil
15、le,MD.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.7. Hazards7.1 Precautions applying to the use of low-intensity X-raysshould be observed.7.2 Users should be aware that sample concentrations usedin this test method may be higher
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC95819922007STANDARDTESTMETHODFORPARTICLESIZEDISTRIBUTIONOFALUMINAORQUARTZBYXRAYMONITORINGOFGRAVITYSEDIMENTATION

链接地址:http://www.mydoc123.com/p-508981.html