ASTM C927-1980(2004) Standard Test Method for Lead and Cadmium Extracted from the Lip and Rim Area of Glass Tumblers Externally Decorated with Ceramic Glass Enamels《外表用陶瓷玻璃釉装饰的玻璃酒杯.pdf
《ASTM C927-1980(2004) Standard Test Method for Lead and Cadmium Extracted from the Lip and Rim Area of Glass Tumblers Externally Decorated with Ceramic Glass Enamels《外表用陶瓷玻璃釉装饰的玻璃酒杯.pdf》由会员分享,可在线阅读,更多相关《ASTM C927-1980(2004) Standard Test Method for Lead and Cadmium Extracted from the Lip and Rim Area of Glass Tumblers Externally Decorated with Ceramic Glass Enamels《外表用陶瓷玻璃釉装饰的玻璃酒杯.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 927 80 (Reapproved 2004)Standard Test Method forLead and Cadmium Extracted from the Lip and Rim Area ofGlass Tumblers Externally Decorated with Ceramic GlassEnamels1This standard is issued under the fixed designation C 927; the number immediately following the designation indicates th
2、e year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the determination of lead
3、 andcadmium extracted by acetic acid from the lip and rim area ofglassware used for drinking and which is exteriorly decoratedwith ceramic glass enamels. The procedure of extraction maybe expected to accelerate the release of lead and cadmium fromthe decorated area and to serve, therefore, as a seve
4、re test thatis unlikely to be matched under the actual conditions of usageof such glassware. This test method is specific for lead andcadmium.NOTE 1For additional information see Test Method C 738.1.2 The values stated in acceptable metric units are to beregarded as the standard. The values given in
5、 parentheses arefor information only.1.3 This standard may involve hazardous materials, opera-tions, and equipment. This standard does not purport toaddress all of the safety concerns associated with its use. It isthe responsibility of the user of this standard to establishappropriate safety and hea
6、lth practices and determine theapplicability of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 738 Test Method for Lead and Cadmium Extracted fromGlazed Ceramic Surfaces3. Terminology3.1 Definitions:3.1.1 ceramic glass decorationsceramic glass enamelsfused to glassw
7、are at temperatures above 425C (800F) toproduce a decoration.3.1.2 ceramic glass enamels (also ceramic enamels or glassenamels)predominately colored, silicate glass fluxes used todecorate glassware.3.1.3 lip and rim areathat part of a drinking vessel whichextends 20 mm below the rim on the outside o
8、f the specimen.4. Summary of Test Method4.1 Lead and cadmium are extracted from the lip and rimarea of the article under test by leaching with a 4 % acetic acidsolution at 20 to 24C (68 to 75F) for 24 h and are measuredby atomic absorption spectrophotometry using specific hollowcathode or electrodel
9、ess discharge lamps for lead and cadmiumrespectively. Results are reported as micrograms per millilitre(ppm) extracted relative to the internal volume of the glassarticle.5. Significance and Use5.1 The heavy metals, lead and cadmium, are known tocause serious health effects in man if consumed in exc
10、ess. It is,therefore, important to measure the amount that may beextracted from an area of the glass drinking vessel in contactwith the lip. Even though the amount of lead and cadmiumextracted by this test method is in no way representative of theamount of the metals extracted by actual lip contact,
11、 therelative magnitude of metals extracted from one test specimenin relation to another test specimen provides an effective toolfor discrimination.6. Interferences6.1 Since specific hollow cathode lamps or electrodelessdischarge lamps for lead and cadmium are used, there are nointerferences.7. Appar
12、atus7.1 Atomic Absorption Spectrophotometer (AAS), equippedwith a 102-mm (4-in.) single slot or Boling burner head anddigital concentration readout attachment (DCR) if available.This instrument should have a sensitivity of about 0.5 g/mL of1This test method is under the jurisdiction of ASTM Committe
13、e C14 on Glassand Glass Products and is the direct responsibility of Subcommittee C14.10 onGlass Decoration. It was developed jointly by ASTM Committee C-14 and C-21 onCeramic Whitewares and Related Products, the Society of Glass Decorators A-20Subcommittee on Ceramic Enameled Decorated Glass Tumble
14、rs, and an Inter-agency Task Force consisting of FDA, EPA, and CPSC of the U.S. Government.Current edition approved Oct. 1, 2004. Published October 2004. Originallyapproved in 1980. Last previous edition C 927 - 80 (1999).2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontac
15、t ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.lead for 1 % absorption
16、and a sensitivity of about 0.025 g/mLof cadmium for 1 % absorption. Use the operating conditionsas specified in the instrument manufacturers analytical meth-ods manual.7.2 Hollow Cathode or Electrodeless Discharge LeadLamp, set at 283.3 nm.7.3 Hollow Cathode or Electrodeless Discharge CadmiumLamp, s
17、et at 228.8 nm.7.4 Glassware of chemically resistant borosilicate glass foruse in preparing and storing reagents and solutions, and for useas test specimen containers.7.5 Detection limits of lead and cadmium shall be deter-mined and reported for individual instruments. In this testmethod, the detect
18、ion limit shall be defined as twice the meannoise level at 0 g/mL. Representative detection limits wouldbe approximately 0.01 to 0.03 g/mL for lead and 0.0005 to0.0010 g/mL for cadmium.8. Reagents8.1 Purity of ReagentsReagent grade chemicals shall beused in all tests. Unless otherwise indicated, it
19、is intended thatall reagents shall conform to the specifications of the Commit-tee on Analytical Reagents of the American Chemical Society,where such specifications are available.3Other grades may beused provided it is first ascertained that the reagent is ofsufficiently high purity to permit its us
20、e without lessening theaccuracy of the determination. Analyze each new batch ofreagents for lead and cadmium.8.2 Purity of WaterUnless otherwise indicated, referencesto water shall be understood to mean distilled or deionizedwater.8.3 Acetic Acid (4 volume %)Mix 1 volume of glacialacetic acid with 2
21、4 volumes of water.8.4 Cadmium Standard Stock Solution (1000 g/mL ofcadmium)Dissolve 0.9273 g of anhydrous cadmium sulfatein 250 mL of 1 % HCl (8.6) and dilute to 500 mL with 1 %HCl. Commercially available standard cadmium solutions mayalso be used.8.5 Detergent RinseAdd 2 mL of hand dishwashingdete
22、rgent to 1 L of lukewarm tap water.8.6 Hydrochloric Acid (1 weight %)Mix 1 volume ofconcentrated hydrochloric acid (HCl, sp gr 1.19) with 37volumes of water.8.7 Lead Standard Stock Solution (1000 g/mL)Dissolve1.598 g of lead nitrate (Pb(NO3)2) in 4 % acetic acid and diluteto 1 L with 4 % acetic acid
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC92719802004STANDARDTESTMETHODFORLEADANDCADMIUMEXTRACTEDFROMTHELIPANDRIMAREAOFGLASSTUMBLERSEXTERNALLYDECORATEDWITHCERAMICGLASSENAMELS

链接地址:http://www.mydoc123.com/p-508849.html