《ASTM C890-2006 Standard Practice for Minimum Structural Design Loading for Monolithic or Sectional Precast Concrete Water and Wastewater Structures《用于设计最小负荷结构的整体或分段预制混凝土贮水和废水管道的标准实.pdf》由会员分享,可在线阅读,更多相关《ASTM C890-2006 Standard Practice for Minimum Structural Design Loading for Monolithic or Sectional Precast Concrete Water and Wastewater Structures《用于设计最小负荷结构的整体或分段预制混凝土贮水和废水管道的标准实.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 890 06Standard Practice forMinimum Structural Design Loading for Monolithic orSectional Precast Concrete Water and WastewaterStructures1This standard is issued under the fixed designation C 890; the number immediately following the designation indicates the year oforiginal adoption or
2、, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice describes the minimum loads to be appliedwhen designing monolith
3、ic or sectional precast concrete waterand wastewater structures with the exception of concrete pipe,box culverts, utility structures, and material covered in Speci-fication C 478.1.2 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is therespon
4、sibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.3 The values stated in inch-pound units are to be regardedas the standard. The values given in parentheses are providedfor information
5、 only.2. Referenced Documents2.1 ASTM Standards:2C 478 Specification for Precast Reinforced Concrete Man-hole Sections2.2 AASHTO Standard:Standard Specifications for Highway Bridges, 16th Edi-tion32.3 ACI Standard:ACI 318 Building Code Requirements for Reinforced Con-crete43. Terminology3.1 Definiti
6、ons of Terms Specific to This Standard:3.1.1 above ground structuresall structures with theirbase at or above ground.3.1.2 bearing loadsthe foundation pressure reaction to allother loads acting on the structure.3.1.3 below ground structuresall structures other thanthose with their base at or above g
7、round.3.1.4 dead loadsthe mass of the structure and all perma-nent loads imposed on the structure.3.1.5 equipment loadsloads induced into the structure byequipment installed on mounting devices cast into the struc-ture.3.1.6 hydrostatic loadsall pressures due to the weight ofwater or other liquids.3
8、.1.7 lateral earth loadsthe lateral pressure due to theeffective weight of adjacent earth backfill.3.1.8 lifting loadsthe forces induced into the structureduring handling at the precast plant and the construction site.3.1.9 surcharge loadsthe lateral pressure due to verticalloads superimposed on the
9、 adjacent earth backfill.3.1.10 traffc loadsall loads superimposed on the structureor adjacent earth backfill due to vehicles or pedestrians.3.1.11 water and wastewater structuressolar heating res-ervoirs, septic tanks, cisterns, holding tanks, leaching tanks,extended aeration tanks, wet wells, pump
10、ing stations, greasetraps, distribution boxes, oil-water separators, treatment plants,manure pits, catch basins, drop inlets, and similar structures.4. Significance and Use4.1 This practice is intended to standardize the minimumloads to be used to structurally design a precast product.4.2 The user i
11、s cautioned that he must properly correlate theanticipated field conditions and requirements with the designloads. Field conditions may dictate loads greater than mini-mum.5. Design Loads5.1 Dead Loads:5.1.1 Permanent vertical loads typically include the weightof the road bed, walkways, earth backfi
12、ll, and access openingcovers.1This practice is under the jurisdiction of ASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.30 on Waterand Wastewater Containers.Current edition approved Jan. 1, 2006. Published January 2006. Originallyapproved in 1978.
13、 Last previous edition approved in 1999 as C 89091 (1999)e1.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3
14、Available from the American Association of State Highway and TransportationOfficials, 444 N. Capitol St., Washington, DC 20001.4Available from the American Concrete Institute, Box 19150, Detroit, MI48219-0150.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19
15、428-2959, United States.5.1.2 Recommended unit weights of materials for design areshown in Table 1.5.2 Traffc Loads:5.2.1 The vehicle and pedestrian loadings are shown inTable 2.5.2.2 The arrangement and spacing of vehicle wheels areshown in Fig. 1 and Fig. 2.5.2.3 Distribution of Wheel Loads throug
16、h Earth Fills:5.2.3.1 For structures where vehicle wheels contact the topsurface of the structure, the vehicle wheel loads will bedistributed over an area as shown in Fig. 3. The loaded areawill be:A 5 W 3 L (1)where:A = wheel load area, ft2(m2),W = wheel width, ft (m), andL = wheel length, ft (m).5
17、.2.3.2 For below ground structures where backfill separatesthe vehicle wheels and the top surface of the structure, thevehicle wheel loads will be distributed as a truncated pyramidas shown in Fig. 4.The loaded area will be:A 5 W 1 1.75 H! 3 L 1 1.75 H! (2)where:A = wheel load area, ft2(m2),W = whee
18、l width, ft (m),L = wheel length, ft (m), andH = height of backfill between wheels and structure, ft (m).5.2.3.3 When several distributed wheel load areas overlap,the total wheel load will be uniformly distributed over acomposite area defined by the outside limits of the individualareas. Such a whee
19、l load distribution is shown in Fig. 5.5.2.3.4 When the dimensions of the distributed load area orthe composite distributed load area exceed the top surface areaof the structure, only that portion of the distributed load withinthe top surface area will be considered in the design.5.2.4 The effects o
20、f impact will increase the live wheel loadsdesignated as A-16, A-12, and A-8 as shown in Table 3.TABLE 1 Unit Weights of MaterialsMaterial Weight, lbf/ft3(N/m3)Concrete (plain or reinforced) 150 (23 600)Lightweight Concrete (reinforced) 100 to 130 (15 700 to 20 400)Cast Iron 450 (70 700)Steel 490 (7
21、7 000)Aluminum 175 (27 500)Earth Fill 100 to 150 (15 700 to 23 600)Macadam 140 (22 000)TABLE 2 Vehicle and Pedestrian Load DesignationsDesignation Load, max UsesA-16 (HS20-44)A16 000 lbf (71 200 N) per wheel heavy trafficA-12 (HS15-44)A12 000 lbf (53 400 N) per wheel medium trafficA-8 (H10-44)A8 000
22、 lbf (35 600 N) per wheel light trafficA-03 300 lbf/ft2(14 400 Pa) walkwaysAThe designations in parentheses are corresponding ASSHTO designations.DesignationLoad at A Load at B Load at Clbf N lbf N lbf NA-16 (HS20-44)A4 000 17 800 16 000 71 200 12 000 53 400A-12 (HS15-44)A3 000 13 300 12 000 53 400
23、8 000 35 600A-8 (H10-44)A2 000 8 900 8 000 35 600 6 000 26 700AThe designations in parentheses are corresponding ASSHTO designations.FIG. 1 Single Vehicle Traffic Loads and SpacingC8900625.3 Hydrostatic Loads:5.3.1 The water pressure acting on any point on the outsidesurface of the structure is:PW5
24、WW3 HW(3)where:PW= hydrostatic pressure, lbf/ft2(Pa),WW= unit weight of water, lbf/ft3(N/m3), andHW= distance from the ground water surface to the pointon the structure under consideration, ft (m).5.3.2 The liquid pressure acting on any point on the insidesurface of the structure is:PL5 WL3 HL(4)whe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC8902006STANDARDPRACTICEFORMINIMUMSTRUCTURALDESIGNLOADINGFORMONOLITHICORSECTIONALPRECASTCONCRETEWATERANDWASTEWATERSTRUCTURES

链接地址:http://www.mydoc123.com/p-508676.html