《ASTM C604-2002(2007)e1 Standard Test Method for True Specific Gravity of Refractory Materials by Gas-Comparison Pycnometer《用气体比重法测定耐火材料真实比重的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C604-2002(2007)e1 Standard Test Method for True Specific Gravity of Refractory Materials by Gas-Comparison Pycnometer《用气体比重法测定耐火材料真实比重的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 604 02 (Reapproved 2007)1Standard Test Method forTrue Specific Gravity of Refractory Materials by Gas-Comparison Pycnometer1This standard is issued under the fixed designation C 604; the number immediately following the designation indicates the year oforiginal adoption or, in the cas
2、e of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEUnits of measure statement was added editorially in March 2009.1. Scope1.1 This test method covers
3、 the determination of the truespecific gravity of solid materials, and is particularly useful formaterials that easily hydrate which are not suitable for test withTest Method C 135. This test method may be used as analternate for Test Method C 135, Test Method C 128, and TestMethod C 188 for determi
4、ning true specific gravity.1.2 UnitsThe values stated in SI units are to be regardedas standard. No other units of measurement are included in thisstandard.1.2.1 ExceptionIn 7.3 the equivalent SI unit is expressedin parenthesis.1.3 This standard does not purport to address all of thesafety concerns,
5、 if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 128 Test Method for Density, Relative Dens
6、ity (SpecificGravity), and Absorption of Fine AggregateC 135 Test Method for True Specific Gravity of RefractoryMaterials by Water ImmersionC 188 Test Method for Density of Hydraulic Cement3. Summary of Test Method3.1 The sample is powdered to ensure permeation of gasinto all pores. For practical pu
7、rposes this is assumed to be truewhen the sample passes a No. 325 (45-m) sieve. The volumeof a carefully weighed powdered sample which has first beenheated to drive off moisture and undesired combined water ismeasured by the gas-comparison pycnometer. Density is cal-culated from the sample weight in
8、 grams divided by its volumein cubic centimetres. This is also the specific gravity of thesample at room temperature compared to water at 4C.3.2 The principle of the gas-comparison pycnometer is asfollows: There are two chambers and two pistons as sketchedin Fig. 1. For purposes of illustration, the
9、 chambers areassumed to be equal in volume, and there is no sample in eithercylinder. Under these conditions, with the coupling valveclosed, any change in the position of one piston must beduplicated by an identical stroke in the other in order tomaintain the same pressure on each side of the differ
10、entialpressure indicator.3.3 If a sample, Vx, is inserted into chamber B, the couplingvalve closed and both pistons advanced the same amount fromposition 1 to position 2, the pressures will not remain the same.However the pressures can be maintained equal if piston Binstead is moved only to position
11、 3. Then the remainingdisplacement dx, from position 3 to position 2, is equal to thevolume of the sample, Vx. If piston A always is advancedexactly the same distance each time a measurement is made,the distance that piston B differs from position 2, when thepressures in both cylinders are equal, wi
12、ll always be propor-tional to the volume, Vx. The distance (dx) between positions 2and 3 can be calibrated and made to read directly in terms ofcubic centimetres, employing a digital counter.4. Significance and Use4.1 The true specific gravity of a material is the ratio of itstrue density, determine
13、d at a specific temperature, to the truedensity of water, determined at a specific temperature. Thus,the true specific gravity of a material is a primary propertywhich is related to chemical and mineralogical composition.4.2 This test method is particularly useful for hydratablematerials which are n
14、ot suitable for test with Test MethodC 135.4.3 For refractory raw materials and products the truespecific gravity is a useful value for: classification, detectingdifferences in chemical composition between supposedly like1This test method is under the jurisdiction of ASTM Committee C08 onRefractorie
15、s and is the direct responsibility of Subcommittee C08.03 on PhysicalProperties.Current edition approved March 1, 2007. Published April 2007. Originallyapproved in 1967. Last previous edition approved in 2002 as C 604 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact
16、 ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.samples, indicating miner
17、alogical phases or phase changes,calculating total porosity when the bulk density is known, andfor any other test method that requires this value for thecalculation of results.4.4 This test method is a primary standard method which issuitable for use in specifications, quality control, and researcha
18、nd development. It can also serve as a referee test method inpurchasing contracts or agreements.4.5 Fundamental assumptions inherent in this test methodare the following:4.5.1 The sample is representative of the material in general,4.5.2 The total sample has been reduced to the particle sizespecifie
19、d,4.5.3 No contamination has been introduced during process-ing of the sample,4.5.4 The ignition of the sample has eliminated all free orcombined water without inducing sintering or alteration,4.5.5 An inert gas (helium) has been used in the test, and4.5.6 The test method has been conducted in a met
20、iculousmanner.4.5.7 Deviation from any of these assumptions negates theusefulness of the results.4.6 In interpreting the results of this test method it must berecognized that the specified sample particle size is signifi-cantly finer than specified for Test Method C 135. Even thisfiner particle size
21、 for the sample does not preclude the presenceof some closed pores, and the amount of residual closed poresmay vary between materials or even between samples of thesame or like materials. The values generated by this testmethod may, therefore, be very close approximations ratherthan accurate represe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC60420022007E1STANDARDTESTMETHODFORTRUESPECIFICGRAVITYOFREFRACTORYMATERIALSBYGASCOMPARISONPYCNOMETER

链接地址:http://www.mydoc123.com/p-507741.html