1、Designation: C509 06 (Reapproved 2011)Standard Specification forElastomeric Cellular Preformed Gasket and SealingMaterial1This standard is issued under the fixed designation C509; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the
2、 year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This specification applies t
3、o those elastomeric cellularmaterials of a firm grade that are manufactured in preformedshapes for use as gaskets and for use as sealing materials, in theform of compression seals or gaskets, or both, for glazing otherbuilding joint applications.NOTE 1For softer cellular elastomeric materials used i
4、n secondarysealing applications, refer to Specification D1056.1.2 Test Method C1166, as referenced in this specification,should be used to measure and describe the properties ofmaterials, products, or assemblies in response to heat andflame under controlled laboratory conditions and should not beuse
5、d to describe or appraise the fire hazard or fire risk ofmaterials, products, or assemblies under actual fire conditions.However, results of this test may be used as elements of a firerisk assessment which takes into account all of the factorswhich are pertinent to an assessment of the fire hazard o
6、f aparticular end use.1.3 The following precautionary caveat pertains only to thetest method portion, Section 11, of this specification: Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establ
7、ish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.1.4 The committee with jurisdiction over this standard is notaware of any comparable standards published by other orga-nizations.2. Referenced Documents2.1 ASTM Standards:2C717 Terminol
8、ogy of Building Seals and SealantsC1083 Test Method for Water Absorption of Cellular Elas-tomeric Gaskets and Sealing MaterialsC1166 Test Method for Flame Propagation of Dense andCellular Elastomeric Gaskets and AccessoriesD395 Test Methods for Rubber PropertyCompression SetD412 Test Methods for Vul
9、canized Rubber and Thermo-plastic ElastomersTensionD746 Test Method for Brittleness Temperature of Plasticsand Elastomers by ImpactD865 Test Method for RubberDeterioration by Heating inAir (Test Tube Enclosure)D925 Test Methods for Rubber PropertyStaining of Sur-faces (Contact, Migration, and Diffus
10、ion)D1056 Specification for Flexible Cellular MaterialsSponge or Expanded RubberD1149 Test Methods for Rubber DeteriorationCrackingin an Ozone Controlled Environment3. Terminology3.1 DefinitionsRefer to Terminology C717 for the follow-ing terms used in this specification: cellular material, elasto-m
11、eric, gasket glazing, seal, and sealing material.4. Materials and Manufacture4.1 Elastomeric cellular materials furnished to this specifi-cation shall be manufactured from natural rubber, syntheticrubber, rubber-like materials, or mixtures of these, with addedcompounding ingredients of such nature a
12、nd quality that, withproper curing, the finished product will comply with thisspecification.4.2 The cured compounds shall be suitable for use whereresistance to sunlight, weathering, oxidation, and permanentdeformation under load are of prime importance.4.3 The manufacturing process shall be such to
13、 ensure ahomogeneous cellular material free of defects that may affectserviceability.4.4 Although under this specification the manufacturer ispermitted to choose constituent materials, there is no implica-tion that the several compounds are equivalent in all physicalproperties.Any special characteri
14、stics other than those requiredby this specification, which may be needed for specific1This specification is under the jurisdiction of ASTM Committee C24 onBuilding Seals and Sealants and is the direct responsibility of Subcommittee C24.73on Compression Seal and Lock Strip Gaskets.Current edition ap
15、proved June 1, 2011. Published August 2011. Originallyapproved in 1963. Last previous edition approved in 2006 as C509 06. DOI:10.1520/C0509-06R11.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandard
16、s volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.applications, shall be specified by the purchaser, since suchcharacteristics may influence the choi
17、ce of base materials andother ingredients.5. Physical Properties5.1 The material shall conform to the requirements pre-scribed in Table 1.6. Dimensional Tolerances6.1 Permissible variation in cross-sectional dimensions shallbe as specified in Table 2 unless otherwise agreed uponbetween the purchaser
18、 and the supplier.7. Workmanship, Finish, and Appearance7.1 The elastomeric cellular materials shall be manufacturedand processed in a careful and workmanlike manner inaccordance with the best commercial practices.7.2 The surfaces of the finished material shall be reasonablysmooth and free of excess
19、ive talc or bloom.7.3 Unless otherwise specified, the material shall be black.When colored material is desired, it is recommended that othertests, agreed upon between the purchaser and the supplier, beconducted to ensure color stability.8. Number of Tests and Retests8.1 Any material that fails in on
20、e or more of the testrequirements may be retested by making two additional testsfor the requirements in which failure occurs. Failure in onesuch retest shall be cause for final rejection.8.2 Rejected material shall be disposed of as directed by thesupplier.9. Significance and Use9.1 Flame Propagatio
21、n:9.1.1 This specification has two options:9.1.1.1 Option IFlame propagation test is required.9.1.1.2 Option IIFlame propagation test is not required.9.1.2 In case no option is specified, Option I will apply.9.2 This specification has two classifications as related toozone resistance. These are Type
22、 I and Type II, with the latterhaving the greater resistance to ozone. The type should bespecified when making reference to this specification but in theevent that the type is not specified, Type II shall apply.NOTE 2Type II is included in this specification for use where greaterozone resistance is
23、required.10. Sampling10.1 When possible, the completed manufactured productof a suitable section thereof shall be used for the tests specified.Representative samples of the lot being examined shall beselected at random as required.10.2 When the finished product does not lend itself totesting or to t
24、he taking of test specimens because of compli-cated shape, small size, metal or fabric inserts, or other reasons,standard test strips shall be prepared. The standard extrudedspecimens for testing, except where a specific specimen size isdefined by a particular test method, shall be 6.4 mm (14 in.)th
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC50920062011STANDARDSPECIFICATIONFORELASTOMERICCELLULARPREFORMEDGASKETANDSEALINGMATERIAL 多孔 弹性 成型

链接地址:http://www.mydoc123.com/p-466890.html