ASTM C494 C494M-2011 Standard Specification for Chemical Admixtures for Concrete《混凝土用化学添加剂的标准规范》.pdf
《ASTM C494 C494M-2011 Standard Specification for Chemical Admixtures for Concrete《混凝土用化学添加剂的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C494 C494M-2011 Standard Specification for Chemical Admixtures for Concrete《混凝土用化学添加剂的标准规范》.pdf(10页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C494/C494M 11Standard Specification forChemical Admixtures for Concrete1This standard is issued under the fixed designation C494/C494M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year of last revision. A numbe
2、r in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope*1.1 This specification covers materials for use as chemicaladm
3、ixtures to be added to hydraulic-cement concrete mixturesin the field for the purpose or purposes indicated for the eighttypes as follows:1.1.1 Type AWater-reducing admixtures,1.1.2 Type BRetarding admixtures,1.1.3 Type CAccelerating admixtures,1.1.4 Type DWater-reducing and retarding admixtures,1.1
4、.5 Type EWater-reducing and accelerating admixtures,1.1.6 Type FWater-reducing, high range admixtures,1.1.7 Type GWater-reducing, high range, and retardingadmixtures, and1.1.8 Type SSpecific performance admixtures.1.2 This specification stipulates tests of an admixture withsuitable concreting materi
5、als as described in 11.1-11.3 or withcement, pozzolan, aggregates, and an air-entraining admixtureproposed for specific work (11.4). Unless specified otherwiseby the purchaser, the tests shall be made using concretingmaterials as described in 11.1-11.3.NOTE 1It is recommended that, whenever practica
6、ble, tests be madeusing the cement, pozzolan, aggregates, air-entraining admixture, and themixture proportions, batching sequence, and other physical conditionsproposed for the specific work (11.4) because the specific effects producedby chemical admixtures may vary with the properties and proportio
7、ns ofthe other ingredients of the concrete. For instance, Types F and Gadmixtures may exhibit much higher water reduction in concrete mixtureshaving higher cement factors than that listed in 12.1.1.Mixtures having a high range water reduction generally display a higherrate of slump loss. When high-r
8、ange admixtures are used to impartincreased workability (6 to 8-in. slump 150 to 200mm), the effect maybe of limited duration, reverting to the original slump in 30 to 60 mindepending on factors normally affecting rate of slump loss. The use ofchemical admixtures to produce high-slump (flowing) conc
9、rete is coveredby Specification C1017/C1017M.NOTE 2The purchaser should ensure that the admixture supplied foruse in the work is equivalent in composition to the admixture subjected totest under this specification (see Section 6, Uniformity and Equivalence).NOTE 3Admixtures that contain relatively l
10、arge amounts of chloridemay accelerate corrosion of prestressing steel. Compliance with therequirements of this specification does not constitute assurance of accept-ability of the admixture for use in prestressed concrete.1.3 This specification provides for three levels of testing.1.3.1 Level 1Duri
11、ng the initial approval stage, proof ofcompliance with the performance requirements defined inTable 1 demonstrates that the admixture meets the require-ments of this specification.Admixtures (except for Types B, C,E, and S) shall qualify for provisional compliance when thephysical requirements and a
12、ny of the alternative compressivestrength requirements in Table 1 are met. If subsequent testresults at 6 months or one year fail to meet the standardrequirement of 100 % of reference strength, the compliance ofthe admixture to this standard is withdrawn and all users of theadmixture shall be notifi
13、ed immediately. Uniformity andequivalence tests of Section 6 shall be carried out to provideresults against which later comparisons can be made (See Note4).NOTE 4Allowing for provisional compliance while retaining longerterm compressive strength requirements promotes more rapid qualificationof new m
14、aterials, but also provides assurance that new admixturetechnologies will not exhibit unexpected longer term performance. Thealternative compressive strength requirements in Table 1 are based onstatistical analysis of 103 Specification C494/C494M evaluation tests. Thealternative requirements corresp
15、ond to a 99 % probability of passingsubsequent test age requirements.21.3.2 Level 2Limited retesting is described in 5.2, 5.2.1and 5.2.2. Proof of compliance with the requirements of Table1 demonstrates continued conformity of the admixture with therequirements of the specification.1.3.3 Level 3For
16、acceptance of a lot or for measuringuniformity within or between lots, when specified by thepurchaser, the uniformity and equivalence tests of Section 6shall be used.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system
17、 may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conformancewith the standard.1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct
18、responsibility of SubcommitteeC09.23 on Chemical Admixtures.Current edition approved July 1, 2011. Published August 2011. Originallyapproved in 1962. Last previous edition approved in 2010 as C494/C494M10a.DOI: 10.1520/C0494_C0494M-11.2Supporting data have been filed at ASTM International Headquarte
19、rs and maybe obtained by requesting Research Report RR:C09-1030.1*A Summary of Changes section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.1.5 The text of this standard references notes and foot
20、noteswhich provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be consideredas requirements of the standard.1.6 The following precautionary caveat pertains only to thetest method sections, Sections 11-18 of this Specification: Thisstandard does no
21、t purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard to establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:
22、3C33 Specification for Concrete AggregatesC39/C39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC78 Test Method for Flexural Strength of Concrete (UsingSimple Beam with Third-Point Loading)C136 Test Method for Sieve Analysis of Fine and CoarseAggregatesC138/C138M Test Metho
23、d for Density (Unit Weight),Yield, and Air Content (Gravimetric) of ConcreteC143/C143M Test Method for Slump of Hydraulic-CementConcreteC150 Specification for Portland CementC157/C157M Test Method for Length Change of HardenedHydraulic-Cement Mortar and ConcreteC183 Practice for Sampling and the Amo
24、unt of Testing ofHydraulic CementC192/C192M Practice for Making and Curing ConcreteTest Specimens in the LaboratoryC231 Test Method for Air Content of Freshly Mixed Con-crete by the Pressure MethodC260 Specification for Air-Entraining Admixtures for Con-creteC403/C403M Test Method for Time of Settin
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC494C494M2011STANDARDSPECIFICATIONFORCHEMICALADMIXTURESFORCONCRETE 混凝土 化学 添加剂 标准规范 PDF

链接地址:http://www.mydoc123.com/p-466760.html