ASTM C387 C387M-2006a Standard Specification for Packaged Dry Combined Materials for Mortar and Concrete.pdf
《ASTM C387 C387M-2006a Standard Specification for Packaged Dry Combined Materials for Mortar and Concrete.pdf》由会员分享,可在线阅读,更多相关《ASTM C387 C387M-2006a Standard Specification for Packaged Dry Combined Materials for Mortar and Concrete.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 387/C 387M 06aStandard Specification forPackaged, Dry, Combined Materials for Mortar andConcrete1This standard is issued under the fixed designation C 387/C 387M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers the production, properties,packaging, and testing of packaged, dry, combined materi
3、alsfor concrete and mortars. The types of concrete and mortarcovered are described in the following paragraphs in thissection. Some of the mixtures covered by this specificationmay not be available in some areas.1.1.1 High-Early Strength ConcreteFor concrete buildingand repair jobs requiring a more
4、rapid strength developmentsuch as required for the earlier removal of forms.1.1.2 Normal Strength Concrete:1.1.2.1 Normal Weight ConcreteFor general concretebuilding and repair jobs where thicknesses exceed 50 mm 2in. Typical uses include building or repairing sidewalks,patios, steps, footings, and
5、for setting posts.1.1.2.2 Lightweight Concrete Using Normal Weight SandFor concrete building and repair jobs where lower concreteweights are desirable. These mixtures will produce concretewhich is about 15 to 25 % lighter in weight than normal weightconcrete.1.1.2.3 Lightweight ConcreteFor concrete
6、building andrepair jobs where the lightest concrete weight is desirable.These mixtures will produce concrete which is about 25 to35 % lighter in weight than normal weight concrete.1.1.3 High-Strength MortarFor general concrete workrequiring thicknesses of less than 50 mm 2 in. or where ahigh-strengt
7、h grout mixture is required. Typical uses includetopping, patching, and stuccoing. Often referred to as sand mix.1.1.4 Mortars for Unit MasonryFor laying brick, block,and stone, and for masonry repairs. The following three typesof masonry mortar are covered:1.1.4.1 Type NFor general masonry work req
8、uiring nor-mal mortar properties.1.1.4.2 Type SFor use where a higher strength masonrymortar is required.1.1.4.3 Type MFor use where the highest strength ma-sonry mortar is required.1.2 The values stated in either SI or inch-pound units shallbe regarded separately as standard. The values stated in e
9、achsystem are not exact equivalents; therefore, each system shallbe used independently of the other. Combining values from thetwo systems may result in nonconformance with the standard.1.3 The following safety hazards caveat pertains only to thetest method portion of this specification. This standar
10、d does notpurport to address all of the safety concerns, if any, associatedwith its use. It is the responsibility of the user of this standardto establish appropriate safety and health practices anddetermine the applicability of regulatory limitations prior touse.2. Referenced Documents2.1 ASTM Stan
11、dards:2C33 Specification for Concrete AggregatesC 39/C 39M Test Method for Compressive Strength of Cy-lindrical Concrete SpecimensC91 Specification for Masonry CementC 109/C 109M Test Method for Compressive Strength ofHydraulic Cement Mortars(Using 2-in. or 50-mm CubeSpecimens)C 138/C 138M Test Meth
12、od for Density (Unit Weight),Yield, and Air Content (Gravimetric) of ConcreteC 143/C 143M Test Method for Slump of Hydraulic-Cement ConcreteC 144 Specification for Aggregate for Masonry MortarC 150 Specification for Portland CementC 173/C 173M Test Method for Air Content of FreshlyMixed Concrete by
13、the Volumetric MethodC 185 Test Method for Air Content of Hydraulic CementMortarC 192/C 192M Practice for Making and Curing ConcreteTest Specimens in the LaboratoryC 207 Specification for Hydrated Lime for Masonry Pur-posesC 231 Test Method for Air Content of Freshly MixedConcrete by the Pressure Me
14、thod1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregates and is the direct responsibility of SubcommitteeC09.43 on Packaged Dry Combined Materials.Current edition approved July 1, 2006. Published August 2006. Originallyapproved in 1956. Last previous
15、 edition approved in 2006 as C 387 06.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1*A Summary of Changes
16、section appears at the end of this standard.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.C 260 Specification for Air-Entraining Admixtures for Con-creteC 270 Specification for Mortar for Unit MasonryC 305 Practice for Mechanical Mi
17、xing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC 330 Specification for Lightweight Aggregates for Struc-tural ConcreteC 494/C 494M Specification for Chemical Admixtures forConcreteC 595 Specification for Blended Hydraulic CementsC 618 Specification for Coal Fly Ash and Raw or Calci
18、nedNatural Pozzolan for Use in ConcreteC 702 Practice for Reducing Samples of Aggregate toTesting SizeC 989 Specification for Ground Granulated Blast-FurnaceSlag for Use in Concrete and MortarsC 1157 Performance Specification for Hydraulic CementC 1240 Specification for Silica Fume Used in Cementiti
19、ousMixturesC 1329 Specification for Mortar CementC 1437 Test Method for Flow of Hydraulic Cement MortarC 1438 Specification for Latex and Powder Polymer Modi-fiers for Hydraulic Cement Concrete and MortarC 1506 Test Method for Water Retention of HydraulicCement-Based Mortars and PlastersE 96/E 96M T
20、est Methods for Water Vapor Transmission ofMaterials3. Ordering Information3.1 The purchaser shall specify the material desired asconcrete, high strength mortar, or mortar for use with unitmasonry, and the respective physical requirements as specifiedin Table 1 shall govern.4. Materials4.1 Materials
21、 used as ingredients in packaged, dry, com-bined materials for mortar and concrete shall conform to atleast one of the following requirements:4.1.1 Aggregates, shall conform to Specification C33,Specification C 144, or Specification C 330.4.1.2 Air-Entraining Admixtures, shall conform to Specifi-cat
22、ion C 260.4.1.3 Blended Cement, shall conform to Specification C 595or Performance Specification C 1157.4.1.4 Chemical Admixtures, shall conform to SpecificationC 494/C 494M.4.1.5 Flyash, shall conform to Specification C 618.4.1.6 Ground Granulated Blast-Furnace Slag, shall con-form to Specification
23、 C 989.4.1.7 Hydrated Lime, shall conform to Type S or Type SAofSpecification C 207.4.1.8 Latex and Powder Polymer Modifiers, shall conformto Specification C 1438.NOTE 1Type II latex polymers should not be used in applications thatmay be more than superficially wet in service.4.1.9 Masonry Cement, s
24、hall conform to Specification C91.4.1.10 Mortar Cement, shall conform to SpecificationC 1329.4.1.11 Portland Cement, shall conform to Type I, IA, II,IIA, III or IIIA of Specification C 150.4.1.12 Silica Fume, shall conform to Specification C 1240.5. Preparation of Aggregate5.1 All aggregates shall b
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC387C387M2006ASTANDARDSPECIFICATIONFORPACKAGEDDRYCOMBINEDMATERIALSFORMORTARANDCONCRETEPDF

链接地址:http://www.mydoc123.com/p-466428.html