ASTM C303-2007 Standard Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation《预制块和板型隔热材料尺寸和密度的标准试验方法》.pdf
《ASTM C303-2007 Standard Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation《预制块和板型隔热材料尺寸和密度的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C303-2007 Standard Test Method for Dimensions and Density of Preformed Block and Board-Type Thermal Insulation《预制块和板型隔热材料尺寸和密度的标准试验方法》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 303 07Standard Test Method forDimensions and Density of Preformed Block andBoardType Thermal Insulation1This standard is issued under the fixed designation C 303; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the y
2、ear of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the Department of Defense.1. Scope1.1 This test method covers deter
3、mination of the dimensionsand density of block and board insulation as defined inTerminology C 168.1.2 The values stated in the SI system are to be regarded asthe standard.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibilit
4、y of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C 167 Test Methods for Thickness and Density of Blanketor Batt Thermal InsulationsC 168 Terminology
5、Relating to Thermal InsulationC 390 Practice for Sampling and Acceptance of ThermalInsulation LotsC 870 Practice for Conditioning of Thermal Insulating Ma-terials3. Terminology3.1 GeneralTerminology C 168 shall be considered asapplicable to the terms used in this test method.4. Summary of Test Metho
6、d4.1 The material shall be tested in the “dry” condition or inthe “as manufactured and received” condition (see Note 1) butthe procedure must be consistent with that as given in thematerial specification. If the material is to be tested in the “dry”condition it shall be dried to constant mass. If th
7、e materialspecification does not give conditioning instructions, a condi-tioning environment of 23C 6 2C and 50 6 5 % relativehumidity per Practice C 870 shall be used. From the measuredmass and measured dimensions, the density of the product iscalculated.NOTE 1Some materials may contain volatiles s
8、uch as moisture whenmanufactured or shipped, or both.5. Significance and Use5.1 Dimensional measurements of the product thermal in-sulation are essential in determining compliance of a productwith specification limits. Dimensional measurements of vari-ous test specimens are also required by the spec
9、ific testmethod.5.2 Density measurements of the product insulation areuseful in determining compliance of a product with specifica-tion limits, and in providing a relative gage of product weights.For any one kind of insulation, some important physical andmechanical properties, such as thermal conduc
10、tivity, heatcapacity, strength, etc., bear a specific relationship with itsdensity. In order to design for equipment supports, check thematerial for the “as received density” where the moisturecontent of the product as received and then installed mayconsequential.6. Apparatus6.1 Steel measure, (rule
11、r or tape), graduated in millimetresor better, suitable for measuring dimensions to 6 1.0 % (seeNote 2).6.2 Instrument, such as caliper, dial gage, or micrometergraduated in millimetres or better, with a minimum platediameter of 6 mm, and a maximum plate of 25 by 25 mm. Thisinstrument shall be suita
12、ble for measuring the dimensions to61.0 %. This instrument shall not cause deformation of theproduct when measuring it. The pressure exerted by thismeasuring plate should not exceed 0.245 kN/mm2.6.3 Pin probe depth gage per Test Methods C 167.6.4 Scales, accurate to within5gorwithin 1 % of thespecim
13、en mass (whichever is less). If the material specificationcalls for a greater accuracy, this shall take precedence. If the1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edit
14、ion approved May 1, 2007. Published May 2007. Originallypublished as approved in 1952. Last previous edition approved in 2002 asC 303 02.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume i
15、nformation, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.samples are to be conditioned per Practice C 870 the accuracyshall be within 0.1 %.6.5 Drying Oven.NOTE 2Gene
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC3032007STANDARDTESTMETHODFORDIMENSIONSANDDENSITYOFPREFORMEDBLOCKANDBOARDTYPETHERMALINSULATION 预制

链接地址:http://www.mydoc123.com/p-466226.html