ASTM C302-2013(2017) Standard Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation《预制包覆管道用隔热材料密度和尺寸的标准试验方法》.pdf
《ASTM C302-2013(2017) Standard Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation《预制包覆管道用隔热材料密度和尺寸的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C302-2013(2017) Standard Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation《预制包覆管道用隔热材料密度和尺寸的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C302 13 (Reapproved 2017)Standard Test Method forDensity and Dimensions of Preformed Pipe-Covering-TypeThermal Insulation1This standard is issued under the fixed designation C302; the number immediately following the designation indicates the year oforiginal adoption or, in the case of
2、revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 This test
3、method covers the determination of the dimen-sions and density, after conditioning, of preformed pipe insu-lation.1.1.1 ProcedureAis applicable to sections of one-piece pipecovering or to sections of segmental pipe covering that can bejoined together concentrically and measured as one-piece.1.1.2 Pr
4、ocedure B is applicable to segmental pipe coveringwhere each section of material is measured.1.1.3 Procedure C is applicable to sections of one-piece pipecovering, such as soft foam or mineral wool materials, whereit is possible to penetrate the material.1.2 The values stated in inch-pound units are
5、 to be regardedas the standard. The values given in parentheses are forinformation only.1.3 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety, health, and environ
6、mental practices and deter-mine the applicability of regulatory limitations prior to use.1.4 This international standard was developed in accor-dance with internationally recognized principles on standard-ization established in the Decision on Principles for theDevelopment of International Standards
7、, Guides and Recom-mendations issued by the World Trade Organization TechnicalBarriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods for Thickness and Density of Blanket orBatt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC670 Practice for
8、 Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC870 Practice for Conditioning of Thermal Insulating Ma-terialsE691 Practice for Conducting an Interlaboratory Study toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsSee Terminology C168.4. Summa
9、ry of Test Method4.1 The material to be tested is conditioned to constantweight. The density of the pipe insulation is calculated from theconditioned mass and measured dimensions.5. Significance and Use5.1 Density measurements of preformed pipe insulation areuseful in determining compliance of a pro
10、duct with specifica-tion limits and in providing a relative gage of product weights.For any one kind of insulation some important physical andmechanical properties, such as thermal conductivity, heatcapacity, strength, etc., bear a specific relationship with itsdensity; however, on a density basis,
11、these properties are notdirectly comparable with those for other kinds of material.5.2 The physical dimensions of preformed pipe insulationare important quantities not only for determining the density ofthe pipe insulation but also for determining the conformance tospecifications. The use of multila
12、yer insulations is common,and the dimensions are necessary to ensure proper nesting ofthe layers.6. Apparatus6.1 Flexible Steel Rule, graduated in132-in. or 1.0-mmintervals.6.2 Scale, with sufficient capacity to weigh the specimen towithin 0.01 lb or 5 g.6.3 Pin Probe, as defined in Test Methods C16
13、7.6.4 Steel Rule, graduated in132-in. or 1.0-mm intervals.1This test method is under the jurisdiction ofASTM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edition approved Sept. 1, 2017. Published December 2017. Originallya
14、pproved in 1952. Last previous edition approved in 2013 as C302 13. DOI:10.1520/C0302-13R17.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document S
15、ummary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United StatesThis international standard was developed in accordance with internationally recognized principles on standardization established in the Decision on Princip
16、les for theDevelopment of International Standards, Guides and Recommendations issued by the World Trade Organization Technical Barriers to Trade (TBT) Committee.16.5 Stainless Steel Shim Stock, 2 in. (75 mm) wide, longerthan the circumference of the pipe insulation, and 0.010 in.(0.25 mm) thick.6.6
17、Pi Tape, graduated to read a diameter directly to thenearest132 in. or 1.0 mm.6.7 Pieces of Pipe, on which to install the pipe insulationunder test (only required for Procedure 3).7. Test Specimen7.1 The test specimen shall be of a commercial size.7.2 If sectional pipe segments are to be used for Pr
18、ocedures1 or 3, the sections shall be joined together to form a hollowcylinder.8. Conditioning8.1 Remove any jacket on the specimen unless it is of a typethat would cause disintegration of the specimen upon removal.8.2 Condition the specimen to constant mass in accordancewith Practice C870.9. Proced
19、uresProcedure A9.1 One-Piece Pipe Section:9.1.1 Weigh the conditioned pipe section to the nearest 0.01lb or 5 g.9.1.2 Measure the length of the specimen in six locations,uniformly spaced around its circumference, to the nearest132in. or 1.0 mm.9.1.3 Measure the circumference of the specimen in sixlo
20、cations, uniformly spaced along its length, to the nearest132in. or 1.0 mm.9.1.4 Measure the wall thickness at six locations, uniformlyspaced, three on each end of the specimen, to the nearest132 in.or 1.0 mm.Procedure B9.2 Segmental Pipe Sections:9.2.1 Weigh the conditioned segmental pipe section t
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC30220132017STANDARDTESTMETHODFORDENSITYANDDIMENSIONSOFPREFORMEDPIPECOVERINGTYPETHERMALINSULATION

链接地址:http://www.mydoc123.com/p-466225.html