《ASTM C302-2013 Standard Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation《预制包覆型管道隔热材料密度和尺寸规格的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C302-2013 Standard Test Method for Density and Dimensions of Preformed Pipe-Covering-Type Thermal Insulation《预制包覆型管道隔热材料密度和尺寸规格的标准试验方法》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C302 95 (Reapproved 2007)C302 13Standard Test Method forDensity and Dimensions of Preformed Pipe-Covering-TypeThermal Insulation1This standard is issued under the fixed designation C302; the number immediately following the designation indicates the year oforiginal adoption or, in the c
2、ase of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.This standard has been approved for use by agencies of the U.S. Department of Defense.1. Scope1.1 Thi
3、s test method covers the determination of the dimensions and density, after conditioning, of preformed pipe insulation.1.1.1 Procedure A is applicable to sections of one-piece pipe covering or to sections of segmental pipe covering that can bejoined together concentrically and measured as one-piece.
4、1.1.2 Procedure B is applicable to segmental pipe covering where each section of material is measured.1.1.3 Procedure C is applicable to sections of one-piece pipe covering, such as soft foam or mineral wool materials, where itis possible to penetrate the material.1.2 The values stated in inch-pound
5、 units are to be regarded as the standard. The values given in parentheses are for informationonly.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibilityof the user of this standard to establish appropriate safety and healt
6、h practices and determine the applicability of regulatorylimitations prior to use.2. Referenced Documents2.1 ASTM Standards:2C167 Test Methods for Thickness and Density of Blanket or Batt Thermal InsulationsC168 Terminology Relating to Thermal InsulationC670 Practice for Preparing Precision and Bias
7、 Statements for Test Methods for Construction MaterialsC870 Practice for Conditioning of Thermal Insulating MaterialsE691 Practice for Conducting an Interlaboratory Study to Determine the Precision of a Test Method3. Terminology3.1 DefinitionsSee Terminology C168.4. Summary of Test Method4.1 The mat
8、erial to be tested is conditioned to constant weight. The density of the pipe insulation is calculated from theconditioned mass and measured dimensions.5. Significance and Use5.1 Density measurements of preformed pipe insulation are useful in determining compliance of a product with specificationlim
9、its and in providing a relative gage of product weights. For any one kind of insulation some important physical and mechanicalproperties, such as thermal conductivity, heat capacity, strength, etc., bear a specific relationship with its density; however, on adensity basis, these properties are not d
10、irectly comparable with those for other kinds of material.1 This test method is under the jurisdiction of ASTM Committee C16 on Thermal Insulation and is the direct responsibility of Subcommittee C16.32 on MechanicalProperties.Current edition approved March 1, 2007Nov. 1, 2013. Published April 2007D
11、ecember 2013. Originally approved in 1952. Last previous edition approved in 20012007as C302 95 (Reapproved 2001)(2007). 1. DOI: 10.1520/C0302-95R07.10.1520/C0302-13.2 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Bo
12、ok of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be techn
13、ically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.Copyright ASTM International, 100 Barr Harbor Drive, PO B
14、ox C700, West Conshohocken, PA 19428-2959. United States15.2 The physical dimensions of preformed pipe insulation are important quantities not only for determining the density of thepipe insulation but also for determining the conformance to specifications. The use of multilayer insulations is commo
15、n, and thedimensions are necessary to ensure proper nesting of the layers.6. Apparatus6.1 Flexible Steel Rule, graduated in 132-in. or 1.0-mm intervals.6.2 Scale, with sufficient capacity to weigh the specimen to within 0.01 lb or 5 g.6.3 Pin Probe, as defined in Test Methods C167.6.4 Steel Rule, gr
16、aduated in 132-in. or 1.0-mm intervals.6.5 Stainless Steel Shim Stock, 2 in. (75 mm) wide, longer than the circumference of the pipe insulation, and 0.010 in. (0.25mm) thick.6.6 Pi Tape, graduated to read a diameter directly to the nearest 132 in. or 1.0 mm.6.7 Pieces of Pipe, on which to install th
17、e pipe insulation under test (only required for Procedure 3).7. Test Specimen7.1 The test specimen shall be of a commercial size.7.2 If sectional pipe segments are to be used for Procedures 1 or 3, the sections shall be joined together to form a hollowcylinder.8. Conditioning8.1 Remove any jacket on
18、 the specimen unless it is of a type that would cause disintegration of the specimen upon removal.8.2 Condition the specimen to constant mass in accordance with Practice C870.9. ProceduresProcedure A9.1 One-Piece Pipe Section:9.1.1 Weigh the conditioned pipe section to the nearest 0.01 lb or 5 g.9.1
19、.2 Measure the length of the specimen in six locations, uniformly spaced around its circumference, to the nearest 132 in. or1.0 mm.C302 1329.1.3 Measure the circumference of the specimen in six locations, uniformly spaced along its length, to the nearest 132 in. or1.0 mm.9.1.4 Measure the wall thick
20、ness at six locations, uniformly spaced, three on each end of the specimen, to the nearest 132 in.or 1.0 mm.Procedure B9.2 Segmental Pipe Sections:9.2.1 Weigh the conditioned segmental pipe section to the nearest 0.01 lb or 5 g.9.2.2 Measure the length of the arc formed by the outer surface of the s
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC3022013STANDARDTESTMETHODFORDENSITYANDDIMENSIONSOFPREFORMEDPIPECOVERINGTYPETHERMALINSULATION 预制

链接地址:http://www.mydoc123.com/p-466224.html