ASTM C279-2017 Standard Specification for Chemical-Resistant Masonry Units《抗化学砌块的标准规格》.pdf
《ASTM C279-2017 Standard Specification for Chemical-Resistant Masonry Units《抗化学砌块的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C279-2017 Standard Specification for Chemical-Resistant Masonry Units《抗化学砌块的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C279 13aC279 17Standard Specification forChemical-Resistant Masonry Units1This standard is issued under the fixed designation C279; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in
2、 parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers solid, kiln fired brick and tile made from clay, shale, or mixtures thereof, suitable for indoor andoutdoor use in ma
3、sonry construction subjected to chemical environments (see Terminology C1232).1.2 The brick and tile covered herein are intended for use in chemical environments where resistance to thermal shock may bea consideration. The brick and tile are normally used with chemical-resistant mortars.1.3 The valu
4、es stated in inch-pound units are to be regarded as standard. The values given in parentheses are mathematicalconversions to SI units that are provided for information only and are not considered standard.1.4 This standard does not purport to address all of the safety concerns, if any, associated wi
5、th its use. It is the responsibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.1.5 This international standard was developed in accordance with internationally recognized principles on standa
6、rdizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barriers to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:2C20 Test Methods for Apparent Porosity, Water Abs
7、orption, Apparent Specific Gravity, and Bulk Density of Burned RefractoryBrick and Shapes by Boiling WaterC67 Test Methods for Sampling and Testing Brick and Structural Clay TileC1232 Terminology of MasonryE11 Specification for Woven Wire Test Sieve Cloth and Test Sieves3. Terminology3.1 Definitions
8、For definitions relating to chemical-resistant masonry units, refer to Terminology C1232.4. Classification4.1 The physical and chemical properties of brick and tile differ from supplier to supplier, mainly because their composition isdetermined by the source of raw materials. Regardless of the diffe
9、rences, brick and tile are considered to be one of three types andone of two classes as follows:4.1.1 Type IFor use where low absorption and high acid resistance are not major factors.4.1.2 Type IIFor use where lower absorption and higher acid resistance are required.4.1.3 Type IIIFor use where mini
10、mum absorption and maximum acid resistance are required.NOTE 1Types I, II, and III may not differ significantly in thermal shock resistance. The suitability of a given brick, for a particular application shouldbe determined at the time of purchase by agreement between the purchaser and the supplier.
11、NOTE 2Types I and III were formerly designated Type “H” and “L” respectively.4.1.4 Class SFor use in standard applications.1 This specification is under the jurisdiction of ASTM Committee C15 on Manufactured Masonry Units and is the direct responsibility of Subcommittee C15.02 on Brickand Structural
12、 Clay Tile.Current edition approved Dec. 15, 2013June 1, 2017. Published January 2014July 2017. Originally approved in 1951. Last previous edition approved in 2013 asC279 13.C279 13a. DOI: 10.1520/C0279-13A.10.1520/C0279-17.2 For referencedASTM standards, visit theASTM website, www.astm.org, or cont
13、actASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the ASTM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have bee
14、n made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consult prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document
15、.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States14.1.5 Class XFor use where a higher degree of precision and lower permissible variation in size than that permitted for
16、ClassS is required.5. Physical Properties5.1 StrengthThe brick and tile when tested in accordance with Test Methods C67 shall conform to the requirements formodulus of rupture (flexural strength) for the type specified, as prescribed in Table 1.5.2 Water AbsorptionThe brick and tile when tested in a
17、ccordance with Test Methods C20 shall conform to the requirementsfor water absorption (based on the 2 h boil) for the type specified, as prescribed in Table 1.6. Dimensions and Permissible Variations6.1 SizesThe sizes of the brick and tile shall be as specified by the purchaser. The length, width, a
18、nd depth measurements ofthe brick or tile shall be within 63 % of the specified dimensions for Class S units and within 61.5 % of the specified dimensionsfor Class X units.6.2 WarpageThe brick and tile shall conform to the requirements as shown in Table 2.7. Finish and Appearance7.1 Surface Textures
19、Brick or tile surfaces are often textured in order to promote better bonding. Texturing is accomplishedby scoring, wire cutting, matting, or other means consistent with a manufacturers process. If texturing is done, the protrusion orindentation shall not exceed 18 in. (3 mm) in depth.7.2 The brick a
20、nd tile shall be free of open surface laminations or cracks which would impair the performance of theconstruction.NOTE 3Open laminations or cracks within the brick or tile observed in the brick or tile cut or broken during testing, should be noted with their sizeand number indicated as part of the t
21、est report. If internal open laminations or cracks, or both, are reported, the purchaser shall determine the suitabilityof such brick or tile for his application.7.3 Black HeartBrick or tile when broken may have a dark area that has a steely appearance and is sharply delineated fromthe surrounding n
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC2792017STANDARDSPECIFICATIONFORCHEMICALRESISTANTMASONRYUNITS 化学 砌块 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466170.html