ASTM C260 C260M-2010a(2016) Standard Specification for Air-Entraining Admixtures for Concrete《混凝土加气掺合剂的标准规格》.pdf
《ASTM C260 C260M-2010a(2016) Standard Specification for Air-Entraining Admixtures for Concrete《混凝土加气掺合剂的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C260 C260M-2010a(2016) Standard Specification for Air-Entraining Admixtures for Concrete《混凝土加气掺合剂的标准规格》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C260/C260M 10a (Reapproved 2016)Standard Specification forAir-Entraining Admixtures for Concrete1This standard is issued under the fixed designation C260/C260M; the number immediately following the designation indicates the yearof original adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval.A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 This specification covers materials proposed for use asair-entraining admixtures to be added to concrete mixtures
3、inthe field.1.2 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the two systems may result in non-conf
4、ormancewith the standard.1.3 The text of this specification references notes andfootnotes which provide explanatory material. These notes andfootnotes (excluding those in tables and figures) shall not beconsidered as requirements of the standard.2. Referenced Documents2.1 ASTM Standards:2C183 Practi
5、ce for Sampling and the Amount of Testing ofHydraulic CementC185 Test Method for Air Content of Hydraulic CementMortarC233 Test Method for Air-Entraining Admixtures for Con-crete3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 air-entraining admixture, nfor the purpose of thiss
6、pecification, a material that is used as an ingredient ofconcrete, added to the batch immediately before or during itsmixing, for the purpose of entraining air.4. General Requirements4.1 At the request of the purchaser, the manufacturer shallstate in writing that the air-entraining admixture supplie
7、d foruse in the work is essentially identical in concentration,composition, and performance to the air-entraining admixturetested under this specification.NOTE 1It is recommended that, whenever practicable, tests with theair-entraining admixture be made using all of the ingredients of theconcrete pr
8、oposed for the specific work, because the effect produced bythe air-entraining admixture may vary with the properties of the otheringredients of the concrete.4.2 Requirements for establishing compositional or chemi-cal equivalence of a subsequent lot relative to a previous lotthat was subjected to q
9、uality tests and found to comply with therequirements of 5.1 shall be determined if agreed upon by thepurchaser and the manufacturer. At the request of thepurchaser, the manufacturer shall recommend appropriate testprocedures, such as infrared spectrophotometry (I.R.), pHvalue and solids content, fo
10、r establishing the equivalence ofmaterials from different lots or different portions of the samelot.NOTE 2Ultraviolet light absorption (UV) of solutions and infraredspectroscopy of dried residues have been found to be valuable for thesepurposes. The specific procedures to be employed and the criteri
11、a toestablish equivalence should be stipulated with due regard to the compo-sition and properties of the sample.4.3 At the request of the purchaser, the manufacturer shallstate in writing the chloride content of the air-entrainingadmixture and whether or not chloride was added during itsmanufacture.
12、NOTE 3Admixtures that contain chlorides may accelerate corrosion ofembedded metals.5. Optional Uniformity Requirements5.1 A series of two or more samples from a manufacturinglot will be considered sufficiently uniform to be properlycomposited into a single sample for quality testing providedthey do
13、not differ more than the amounts indicated in 5.4.5.2 A subsequent sample or composite sample shall beconsidered in compliance with these requirements, so long asthey differ from the reference sample by no more than theamounts listed in 5.4. The reference sample is the originalsample tested to meet
14、the requirements of 6.1. Any additionaloptional, appropriate tests, such as infrared spectroscopy andultraviolet light absorption, referred to in 4.2, also shall meetpre-agreed requirements.1This specification is under the jurisdiction of ASTM Committee C09 onConcrete and Concrete Aggregatesand is t
15、he direct responsibility of SubcommitteeC09.23 on Chemical Admixtures.Current edition approved July 1, 2016. Published August 2016. Originallyapproved in 1950. Last previous edition approved in 2010 as C260/C260M10a.DOI: 10.1520/C0260_C0260M-10AR16.2For referenced ASTM standards, visit the ASTM webs
16、ite, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor D
17、rive, PO Box C700, West Conshohocken, PA 19428-2959. United States15.3 Determinations of uniformity shall be made in accor-dance with the procedures given in the sections “Check Testsfor Uniformity” and “Procedure for Residue by Oven Drying”of Test Method C233.5.4 Allowable differences in results of
18、 uniformity determi-nations shall not exceed the following amounts:5.4.1 The manufacturer shall provide an acceptable range ofpH that does not exceed 3.0 pH units. The pH of samples testedshall fall within this range.5.4.2 The air content in percent of Test Method C185mortars prepared from successiv
19、e lots shall not differ by morethan 2.0 from that for the acceptance sample.5.4.3 The manufacturer shall provide acceptable limits ofresidue content not to exceed 612 % of the midpoint of thelimits. The residue content of samples tested shall fall withinthese limits (Note 4).NOTE 4As an example, an
20、admixture may commonly be producedwith residue content ranging from 5.0 to 6.5 %. The manufacturer wouldprovide acceptable limits of 5.06 to 6.44 %, representing 612 % of themidpoint of the limits which is 5.75 %.6. Performance Requirements6.1 The air-entraining admixture shall conform to the re-qui
21、rements in Table 1.6.1.1 Resistance to Freezing and ThawingThe relativedurability factor of concrete containing the admixture undertest shall be not less than 80. The relative durability factor shallbe calculated as follows:DF or DF1! 5 PN/300 (1)RDF 5 DF/DF1! 3100where:DF = durability factor of the
22、 concrete containing theadmixture under test,DF1= durability factor of the concrete containing thereference admixture,P = relative dynamic modulus of elasticity in percent-age of the dynamic modulus of elasticity at zerocycles (values of P will be 60 or greater),N = number of cycles at which P reach
23、es 60 %, or 300if P does not reach 60 % prior to the end of the test(300 cycles), andRDF = relative durability factor.6.1.2 Length ChangeAfter 14 days of drying, the lengthchange of the concrete containing the test admixture shall notbe more than 120 % of that of the concrete containing thereference
24、 admixture. When, after 14 days of drying, the lengthchange of the reference concrete is less than 0.030 %, thelength change of the concrete containing the test admixtureshall not be more than 0.006 percentage points greater than thatof the reference concrete.7. Sampling7.1 Opportunity shall be prov
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC260C260M2010A2016STANDARDSPECIFICATIONFORAIRENTRAININGADMIXTURESFORCONCRETE 混凝土 掺合 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-466132.html