ASTM C191-2018a Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle.pdf
《ASTM C191-2018a Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle.pdf》由会员分享,可在线阅读,更多相关《ASTM C191-2018a Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle.pdf(9页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C191 18C191 18a American Association StateHighway and Transportation Officials StandardAASHTO No.: T131Standard Test Methods forTime of Setting of Hydraulic Cement by Vicat Needle1This standard is issued under the fixed designation C191; the number immediately following the designation
2、indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope*1.1 These test methods determine the time
3、 of setting of hydraulic cement by means of the Vicat needle. Two test methods aregiven; MethodAis the Reference Test Method using the manually operated standard Vicat apparatus, while Method B permits theuse of an automatic Vicat machine that has, in accordance with the qualification requirements o
4、f this method, demonstratedacceptable performance.1.2 The values stated in SI units are to be regarded as standard. No other units of measurement are included in this standard.1.3 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the respons
5、ibilityof the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatorylimitations prior to use.Warning: Fresh hydraulic cementitious mixtures are caustic and may cause chemical burns to skin and tissue upon prolongedexposure.21.4 The te
6、xt of this standard references notes and footnotes which provide explanatory material. These notes and footnotes(excluding those in tables and figures) shall not be considered as requirements of the standard.NOTE 1For the method for determining the time of setting by Gillmore needles, see Test Metho
7、d C266.1.5 This international standard was developed in accordance with internationally recognized principles on standardizationestablished in the Decision on Principles for the Development of International Standards, Guides and Recommendations issuedby the World Trade Organization Technical Barrier
8、s to Trade (TBT) Committee.2. Referenced Documents2.1 ASTM Standards:3C150/C150M Specification for Portland CementC151/C151M Test Method for Autoclave Expansion of Hydraulic CementC183/C183M Practice for Sampling and the Amount of Testing of Hydraulic CementC187 Test Method for Amount of Water Requi
9、red for Normal Consistency of Hydraulic Cement PasteC219 Terminology Relating to Hydraulic CementC266 Test Method for Time of Setting of Hydraulic-Cement Paste by Gillmore NeedlesC305 Practice for Mechanical Mixing of Hydraulic Cement Pastes and Mortars of Plastic ConsistencyC511 Specification for M
10、ixing Rooms, Moist Cabinets, Moist Rooms, and Water Storage Tanks Used in the Testing of HydraulicCements and ConcretesC595/C595M Specification for Blended Hydraulic CementsC1005 Specification for Reference Masses and Devices for Determining Mass and Volume for Use in the Physical Testing ofHydrauli
11、c CementsC1157/C1157M Performance Specification for Hydraulic CementD1193 Specification for Reagent Water3. Terminology3.1 DefinitionsThe terms used in this test method are defined in accordance with Terminology C219.1 These test methods are under the jurisdiction of ASTM Committee C01 on Cement and
12、 is the direct responsibility of Subcommittee C01.30 on Time of Set.Current edition approved June 15, 2018Oct. 1, 2018. Published June 2018October 2018. Originally approved in 1944. Last previous edition approved in 20132018 asC191 13.C191 18. DOI: 10.1520/C0191-18.10.1520/C0191-18A.2 Section on Saf
13、ety, Manual of Cement Testing, Annual Book of ASTM Standards, Vol 04.01.3 For referencedASTM standards, visit theASTM website, www.astm.org, or contactASTM Customer Service at serviceastm.org. For Annual Book of ASTM Standardsvolume information, refer to the standards Document Summary page on the AS
14、TM website.This document is not an ASTM standard and is intended only to provide the user of an ASTM standard an indication of what changes have been made to the previous version. Becauseit may not be technically possible to adequately depict all changes accurately, ASTM recommends that users consul
15、t prior editions as appropriate. In all cases only the current versionof the standard as published by ASTM is to be considered the official document.*A Summary of Changes section appears at the end of this standardCopyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, P
16、A 19428-2959. United States14. Summary of Test Method4.1 A paste that is proportioned and mixed to normal consistency, as described in the Test Method C187, is molded and placedin a moist cabinet and allowed to start setting. Periodic penetration tests are performed on this paste by allowing a 1-mm
17、Vicatneedle to settle into this paste. The Vicat initial time of setting is the time elapsed between the initial contact of cement and waterand the time when the penetration is measured or calculated to be 25 mm.TheVicat final time of setting is the time elapsed betweeninitial contact of cement and
18、water and the time when the needle does not leave a complete circular impression in the paste surface.5. Significance and Use5.1 This test method provides a means of determining compliance with a specification limit for Vicat time of setting. Refer tothe appropriate specification for the cement to d
19、etermine if this test method is used for specification compliance.5.2 Time of setting measured by this method will not necessarily provide the same results as the time of setting of hydrauliccement paste measured by other methods, or the time of setting of mortar or concrete.6. Apparatus6.1 Vicat Ap
20、paratusSee Annex A1.1 and Fig. A1.1. The Vicat apparatus for this test method shall have a movable rod, B, ofmass 300 6 0.5 g.6.1.1 The end of the rod used for measuring penetration shall have a straight steel removable needle with a diameter of 1.006 0.05 mm and length no less than 50 mm.6.1.2 The
21、needle end that contacts the specimen shall be flat, plane, and at right angles to the axis of the rod.6.2 Reference Masses and Devices for Determining Mass, conforming to the requirements of Specification C1005. The devicesfor determining mass shall be evaluated for continuing precise performance u
22、tilizing the procedure in Specification C1005,Appendix X1 using a verification check mass of approximately 1000 g.6.3 Glass Graduates, 200 or 250-mL capacity, and conforming to the requirements of Specification C1005.6.4 Plane non-adsorptive plate, 100 6 5 mm square of similar planeness, corrosivity
23、, and absorptivity to that of glass (seeAnnex A1.1, Fig. A1.1, H).6.5 Flat trowel, having a sharpened straight-edged steel blade 100 to 150 mm in length. The edges when placed on a planesurface shall not depart from straightness by more than 1 mm.6.6 Conical ring, made of a rigid, non-corroding, non
24、-absorbent material and having a height of 40 6 1 mm, an inside diameterat the bottom of 70 6 3 mm, and an inside diameter at the top of 60 6 3 mm (see Annex A1.1, Fig. A1.1, G).6.7 Mixer, bowl, and paddle, conforming to Practice C305.6.8 Automatic Vicat Needle Apparatus for Method BThe apparatus sh
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1912018ASTANDARDTESTMETHODSFORTIMEOFSETTINGOFHYDRAULICCEMENTBYVICATNEEDLEPDF

链接地址:http://www.mydoc123.com/p-465966.html