ASTM C1714 C1714M-2009 Standard Specification for Preblended Dry Mortar Mix for Unit Masonry《砌块用预混合型干拌砂浆的标准规范》.pdf
《ASTM C1714 C1714M-2009 Standard Specification for Preblended Dry Mortar Mix for Unit Masonry《砌块用预混合型干拌砂浆的标准规范》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1714 C1714M-2009 Standard Specification for Preblended Dry Mortar Mix for Unit Masonry《砌块用预混合型干拌砂浆的标准规范》.pdf(4页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1714/C1714M 09Standard Specification forPreblended Dry Mortar Mix for Unit Masonry1This standard is issued under the fixed designation C1714/C1714M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of last rev
2、ision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers masonry mortars whose mate-rials and design requirements are governed by SpecificationC270 but are p
3、reblended dry in a factory instead of producedfrom individual raw materials delivered to the job-site.1.2 The field-sampling, testing, directly comparable testresults, packaging, and the traceability of ingredients of preb-lended dry mortar mix differ from job site mixed mortars andthis standard spe
4、cifically addresses these issues. The tightcontrol of ingredient ratios possible with preblended dry mortaris also covered.1.3 The text of this specification refers to notes and foot-notes, which provide explanatory material. These notes andfootnotes (excluding those in tables and figures) shall not
5、 beconsidered the requirements of the standard.1.4 The values stated in either SI units or inch-pound unitsare to be regarded separately as standard. The values stated ineach system may not be exact equivalents; therefore, eachsystem shall be used independently of the other. Combiningvalues from the
6、 two systems may result in non-conformancewith the standard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-b
7、ility of regulatory limitations prior to use. WarningFreshhydraulic cementitious mixtures are caustic and may causechemical burns to skin and tissue upon prolonged exposure.2. Referenced Documents2.1 ASTM Standards:2C144 Specification for Aggregate for Masonry MortarC260 Specification for Air-Entrai
8、ning Admixtures for Con-creteC270 Specification for Mortar for Unit MasonryC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC780 Test Method for Preconstruction and ConstructionEvaluation of Mortars for Plain and Reinforced UnitMasonryC979 Specification
9、 for Pigments for Integrally ColoredConcreteC1180 Terminology of Mortar and Grout for Unit MasonryC1384 Specification for Admixtures for Masonry MortarsC1437 Test Method for Flow of Hydraulic Cement MortarC1586 Guide for Quality Assurance of Mortars3. Terminology3.1 For definition of terms used in t
10、his specification, refer toTerminology C1180.3.2 Definitions of Terms Specific to This Standard:3.3 preblended dry mortar mix, na mix of dry aggregate;portland cement and hydrated lime, blended hydraulic cement,masonry cement, hydraulic cement, or mortar cement; and maycontain additives used to enha
11、nce one or more properties suchas setting time, workability, water retention, bond and durabil-ity or color pigment; and are thoroughly blended together at thefactory without the addition of water.3.4 additive, na dry mortar material other than the Speci-fication C270 prescribed materials of aggrega
12、te and cementi-tious materials that is added to a dry mortar mix at the batchplant to modify one or more properties of the conventionalmasonry mortar.4. Classification4.1 The classifications of mortars in this specification are asdescribed in Specification C270.5. Specifying Mortar5.1 Specify type o
13、f mortar desired.5.2 Preblended dry mortar mix shall be a mortar meetingboth the requirements of Specification C270 and the require-ments of this specification.1This specification is under the jurisdiction of ASTM Committee C12 onMortars and Grouts for Unit Masonry and is the direct responsibility o
14、f Subcom-mittee C12.03 on Specifications for Mortars.Current edition approved Dec. 15, 2009. Published December 2009. DOI:10.1520/C1714_C1714M-09.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards
15、 volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.2.1 The property specification requirements of Specifica-tion C270 shall govern unless the proport
16、ion specificationrequirements are specifically requested.6. Materials6.1 Materials shall conform to Specification C270 except asfollows:6.1.1 AdditivesShall comply with the admixture require-ments of Specification C1384, except as follows:6.1.1.1 The Specification C1384 reference mortar shall bethis
17、 mortar without the additives and the Specification C1384admixed mortar shall be this mortar with the additives.6.1.1.2 When more than one additive meeting the require-ments of Specification C1384 is used, the chloride limits ofSpecification C1384 shall apply to the sum of all of theseadditives.6.1.
18、1.3 Air entraining materials shall comply with C260.6.1.1.4 Two air-entraining materials shall not be combinedin the mortar mix.6.1.2 Additives used as coloring pigments shall complywith the requirements of C979.7. Manufacture and Use7.1 All of the mortar mix materials shall be dry andmeasured by we
19、ight. The batch scales shall be calibrated atleast annually and shall be capable of consistently measuringeach ingredient to within 1 % of the total batch weight for eachingredient that is added at a rate of at least 20 % of total batchweight, and to within 5 % of the individual ingredients weightfo
20、r each ingredient that is added at a rate of less than 20 % oftotal batch weight.7.2 Each ingredient shall be added within a tolerance of610 % of the individual ingredients target weight.7.3 The weight of each mortar mix ingredient of the finalbatch shall be recorded and archived for every batch.NOT
21、E 1 This batch information is commonly referred to as a batchticket.7.4 A run number or batch number or some other markingused to ensure traceability of the batch shall be assigned toeach batch and retained as part of the batch archive.7.5 The batch information of 7.3 and 7.4 shall be archivedfor a
22、minimum of twelve months from date of manufacture.7.6 All of the dry mortar mix ingredients shall be thor-oughly blended.7.7 The preblended dry mortar mix shall be stored andcovered in such a manner as to prevent hardening, deteriora-tion, contamination, and segregation.7.8 Except for water, no mort
23、ar materials, wet or dry, shallbe added to the mortar mix or the resulting masonry mortarafter the initial blending of the dry mortar materials in the batchplant unless otherwise specified and approved by the manufac-turer of the preblended mortar mix.8. Sampling8.1 For mortars produced to property
24、specifications,samples for determining compliance with this specificationshall be sampled prior to the addition of water.8.2 Samples shall be of sufficient size to conduct all of thedesired testing.At a minimum, take three random samples of atleast 2.3 kg 5 lb each and combine them to form a singles
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1714C1714M2009STANDARDSPECIFICATIONFORPREBLENDEDDRYMORTARMIXFORUNITMASONRY 砌块 混合 型干拌 砂浆 标准规范 PDF

链接地址:http://www.mydoc123.com/p-465622.html