ASTM C1708 C1708M-2012e1 Standard Test Methods for Self-leveling Mortars Containing Hydraulic Cements《含水凝水泥自流平沙浆的标准试验方法》.pdf
《ASTM C1708 C1708M-2012e1 Standard Test Methods for Self-leveling Mortars Containing Hydraulic Cements《含水凝水泥自流平沙浆的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1708 C1708M-2012e1 Standard Test Methods for Self-leveling Mortars Containing Hydraulic Cements《含水凝水泥自流平沙浆的标准试验方法》.pdf(7页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1708/C1708M 121Standard Test Methods forSelf-leveling Mortars Containing Hydraulic Cements1This standard is issued under the fixed designation C1708/C1708M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of
2、last revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1NOTEChanges were made editorially in October 2013.1. Scope1.1 These test methods are appropriate to evaluate theperformance of se
3、lf-leveling mortars containing hydrauliccements that are used to improve the levelness, smoothness,and flatness of existing floors. These materials may be used asan underlayment to receive floor finishes, or as an overlaymentto serve as the wear surface. The self-leveling mortars coveredby these tes
4、t methods consist of proprietary blends of hydrauliccements, along with fine aggregate, polymers, fillers, and otheradditives.1.2 UnitsThe values stated in either SI units or inch-pound units are to be regarded separately as standard. Thevalues stated in each system may not be exact equivalents;ther
5、efore, each system shall be used independently of the other.Combining values from the two systems may result in non-conformance with the standard. Some values have only SI unitsbecause the inch-pound equivalents are not used in practice.1.3 This standard does not purport to address all of thesafety
6、concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.(WarningFreshhydraulic cementitious mixtures are caustic and may causechemical
7、 burns to skin and tissue upon prolonged exposure.)22. Referenced Documents2.1 ASTM Standards:3C109/C109M Test Method for Compressive Strength ofHydraulic Cement Mortars (Using 2-in. or 50-mm CubeSpecimens)C125 Terminology Relating to Concrete and Concrete Ag-gregatesC157/C157M Test Method for Lengt
8、h Change of HardenedHydraulic-Cement Mortar and ConcreteC191 Test Methods for Time of Setting of Hydraulic Cementby Vicat NeedleC305 Practice for Mechanical Mixing of Hydraulic CementPastes and Mortars of Plastic ConsistencyC348 Test Method for Flexural Strength of Hydraulic-Cement MortarsC490 Pract
9、ice for Use ofApparatus for the Determination ofLength Change of Hardened Cement Paste, Mortar, andConcreteC670 Practice for Preparing Precision and Bias Statementsfor Test Methods for Construction MaterialsC778 Specification for SandC928/C928M Specification for Packaged, Dry, Rapid-Hardening Cement
10、itious Materials for Concrete RepairsC1005 Specification for Reference Masses and Devices forDetermining Mass and Volume for Use in the PhysicalTesting of Hydraulic CementsC1107/C1107M Specification for Packaged Dry, Hydraulic-Cement Grout (Nonshrink)E691 Practice for Conducting an Interlaboratory S
11、tudy toDetermine the Precision of a Test Method3. Terminology3.1 DefinitionsFor definitions of terms used in these testmethods, refer to Terminology C125.3.2 Definitions of Terms Specific to This Standard:3.2.1 flow, nof self-leveling mortars, the ability of afreshly-mixed, self-leveling mortar to s
12、pread under its ownweight.3.2.2 healing, nthe ability of a self-leveling mortar toreturn to its original state of levelness and smoothness afterbeing disturbed.3.2.3 mortar, self-leveling, nmortar containing hydrauliccement that, in the fresh state, exhibits flow sufficient to seekgravitational leve
13、ling.1These test methods are under the jurisdiction of ASTM Committee C09 onConcrete and ConcreteAggregates and are the direct responsibility of SubcommitteeC09.43 on Packaged Dry Combined Materials.Current edition approved July 1, 2012. Published September 2012. Orignallyapproved in 2011. Last prev
14、ious edition approved in 2011 as C170811. DOI:10.1520/C1708-12.2Section on Safety Precautions, Manual of Aggregate and Concrete Testing,Annual Book of ASTM Standards, Vol 04.02.3For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. F
15、or Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.2.4 overlayment, n in flooring, a layer of materialusually placed up
16、on the sub-floor that provides a smooth, evensurface to be left exposed as the wear surface of the floor.3.2.5 time, healing, nthe period of time from initialcontact of a self-leveling mortar with mixing water just prior tothe time at which the self-leveling mortar no longer heals butinstead leaves
17、a visible indentation or ridge in the surface afterbeing disturbed.3.2.6 time, starting, nof self-leveling mortars, the timewhen water is brought into contact with the dry ingredients ofa self-leveling mortar.3.2.7 underlayment, n in flooring, a layer of materialusually placed upon the sub-floor tha
18、t provides a smooth, evenbase for flooring.4. Significance and Use4.1 The test methods in this standard are used to evaluatefreshly mixed properties such as the initial flow, flow retention,and healing time as well as hardened properties such ascompressive strength, setting time, and flexural streng
19、th, ofself-leveling mortars.4.2 Tests are conducted under standardized conditions forcomparative purposes and results are not intended to berepresentative of performance under field conditions.5. Standard Laboratory Conditions5.1 Unless otherwise specified, curing and testing of speci-mens shall be
20、conducted at standard laboratory conditionswhich are defined as 23.0 6 2.0 C 73.5 6 3.5 F and therelative humidity of the laboratory shall be not less that 50 %.For optional tests at the manufacturers stated temperatureextremes, the curing and testing temperatures must be within62.0 C 63.5 F of the
21、stated extreme temperatures.6. Sampling6.1 Sample according to the Sampling section of Specifica-tion C1107/C1107M.7. Mixing7.1 Apparatus7.1.1 Use the mixer and scraper as specified in PracticeC305. The standard batch size is 3000 g (See Note 1)ofdryself-leveling mortar. Use a splash guard to preven
22、t excessivesplashing.WarningThe clearances between the paddle and the bowlspecified in Practice C305 are suitable when using mortar madewith standard sand as described in Specification C778.Topermit the mixer to operate freely and to avoid serious damageto the paddle and bowl when coarser aggregates
23、 are used, itmay be necessary to set the clearance adjustment bracket toprovide greater clearances than those specified in 4.1 ofPractice C305.7.1.2 Weighing devices used in determining the mass ofmaterials shall conform to Specification C1005.7.1.3 Atimer accurate to 1 s with a range of at least 60
24、 min.NOTE 1This batch size is used for self-leveling mortars with a typicalfreshly mixed density of approximately 1920 kg/m3120 lb/ft3. Adjustthe batch size as needed to accommodate densities significantly differentfrom the typical value.7.2 Procedure7.2.1 Mix the self-leveling mortar with liquid as
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1708C1708M2012E1STANDARDTESTMETHODSFORSELFLEVELINGMORTARSCONTAININGHYDRAULICCEMENTS 含水 水泥 自流 沙浆

链接地址:http://www.mydoc123.com/p-465599.html