ASTM C1705 C1705M-2009(2016) Standard Specification for Structural Cementitious Panels《结构水泥板的标准规格》.pdf
《ASTM C1705 C1705M-2009(2016) Standard Specification for Structural Cementitious Panels《结构水泥板的标准规格》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1705 C1705M-2009(2016) Standard Specification for Structural Cementitious Panels《结构水泥板的标准规格》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1705/C1705M 09 (Reapproved 2016)Standard Specification forStructural Cementitious Panels1This standard is issued under the fixed designation C1705/C1705M; the number immediately following the designation indicates theyear of original adoption or, in the case of revision, the year of la
2、st revision. A number in parentheses indicates the year of lastreapproval. A superscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers structural cementitious panels.Structural cementitious panels are non-combustible, waterdurabl
3、e, fiber reinforced inorganic composite panels intendedfor use as structural panels. Structural cementitious panels canbe used as floor, roof and wall sheathing when fastened tosupports spaced in accordance with the appropriate span rating.1.2 This specification defines minimum performance re-quirem
4、ents for structural cementitious sheathing panels withrespect to structural performance, dimensional stabilityperformance, dimensional tolerance, noncombustibility, sur-face burning characteristics, long-term durability, waterdurability, mold resistance, density, moment capacity andbending stiffness
5、.1.3 This specification also defines a policy to assure on-going product quality by detecting changes in panel propertiesthat may adversely affect panel performance. Required auditsof quality activities by a third party quality assurance agencyare also defined.1.4 The values stated in either inch-po
6、und units or SI unitsare to be regarded separately as standard. Within the text, theSI units are shown in brackets. The values stated in eachsystem may not be exact equivalents; therefore, each systemshall be used independently of the other. Combining valuesfrom the two systems may result in non-con
7、formance with thestandard.1.5 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations pr
8、ior to use.2. Referenced Documents2.1 ASTM Standards:2C1185 Test Methods for Sampling and Testing Non-Asbestos Fiber-Cement Flat Sheet, Roofing and SidingShingles, and ClapboardsC1704/C1704M Test Method for Sampling and TestingStructural Cementitious PanelsD1037 Test Methods for Evaluating Propertie
9、s of Wood-Base Fiber and Particle Panel MaterialsD1761 Test Methods for Mechanical Fasteners in WoodD3273 Test Method for Resistance to Growth of Mold on theSurface of Interior Coatings in an Environmental Cham-berE84 Test Method for Surface Burning Characteristics ofBuilding MaterialsE136 Test Meth
10、od for Behavior of Materials in a VerticalTube Furnace at 750CE330 Test Method for Structural Performance of ExteriorWindows, Doors, Skylights and Curtain Walls by UniformStatic Air Pressure DifferenceE661 Test Method for Performance of Wood and Wood-Based Floor and Roof Sheathing Under Concentrated
11、Static and Impact LoadsG21 Practice for Determining Resistance of Synthetic Poly-meric Materials to Fungi3. Terminology3.1 Definitions of Terms Specific to This Standard:3.1.1 cross machine direction (XMD), nthe direction per-pendicular to the machine direction.3.1.2 edge, nedges of a panel refer to
12、 the long side of arectangular panel. For example, ona4by8ftpanel, the edgesrefer to the sides of the panel that are 8 ft long.3.1.3 end, nthe end of a panel refers to the short side of arectangular panel. For example, ona4by8ftpanel, the endrefers to the side of the panel that is 4 ft long.1This sp
13、ecification is under the jurisdiction ofASTM Committee C27 on PrecastConcrete Products and is the direct responsibility of Subcommittee C27.40 on GlassFiber Reinforced Concrete.Current edition approved April 1, 2016. Published May 2016. Originallyapproved in 2009. Last previous edition approved in 2
14、009 as C1705/C1705M - 09.DOI: 10.1520/C1705_C1705M-09R16.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.Copy
15、right ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959. United States13.1.4 fiber reinforced inorganic composite, na compositematerial composed primarily of inorganic matrix materialsreinforced primarily with inorganic fibers. Inorganic aggre-gates may be comb
16、ined with the inorganic matrix.3.1.5 machine direction (MD), nthe direction the boardtravels during manufacture.3.1.6 noncombustibility, nterm intended to describe prod-ucts that do not ignite and/or burn when subjected to fire. Testmethods are generally specified by reputable agencies such asASTM,
17、Factory Mutual, Underwriters Lab Inc., etc.3.1.7 performance standard, na standard for productsbased on performance. Performance is measured by tests thatapproximate end-use conditions.3.1.8 plant specification, nthe plant specification is uniqueto each qualified product under a given performance st
18、andard.The specification is used in the plant quality program asaudited under the approved quality control program.3.1.9 qualification policy, npolicy that describes the pro-cedures by which a plant may obtain span rating privileges forperformance-rated products policy.3.1.10 quality assurance polic
19、y, npolicy covering thethird-party auditing of plants quality control program.3.1.11 reference value, nthe numerical value establishedfor the plant specification for a given mechanical or physicalproperty.3.1.12 sample average, nthe average test value, obtainedby summing the observations and dividin
20、g by the number oftests.3.1.13 sample panel, na structural cementitious panelfrom which test specimens are cut and conditioned as neces-sary.3.1.14 sample standard deviation, na measure of testvariation. Calculated as:S 5 =(x22 (x!2/n#/n 2 1 (1)where:S = sample standard deviation,x = test observatio
21、n, andn = number of observations.3.1.15 span rating, nthe recommended maximum center-to-center support spacing in inches for the specified end useunder normal use conditions.3.1.16 specimen, nthe individual test piece cut from asample panel.3.1.17 structural cementitious panel, nnon-combustible,wate
22、r durable, fiber-reinforced inorganic composite panelsintended for use as structural panels.3.1.18 test exposure condition, nthe condition to which apanel is subjected prior to test. Generally, such conditions arereferred to as the dry or wet conditions.3.1.19 test specimen, nspecimens cut from a sa
23、mple panelthat are used for testing.3.1.20 water durability, nperformance of a product aftersustained immersion in water for a specified period of time.4. Performance Specifications for StructuralCementitious Panels4.1 Structural cementitious panels are fiber-reinforced inor-ganic composite panels i
24、ntended for use as structural panels.When used as a floor sheathing panel, structural cementitiouspanels can be used as a combination subfloor and underlayment(single floor grade) or as a sheathing grade panel, which whenused as a floor requires an underlayment panel on top of it. Ineither case, pan
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC1705C1705M20092016STANDARDSPECIFICATIONFORSTRUCTURALCEMENTITIOUSPANELS 结构 水泥板 标准 规格 PDF

链接地址:http://www.mydoc123.com/p-465595.html