《ASTM C1644-2006 Standard Specification for Resilient Connectors Between Reinforced Concrete On-Site Wastewater Tanks and Pipes《加固混凝土在线污水槽和管道之间回弹性连接器的标准实施规程》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1644-2006 Standard Specification for Resilient Connectors Between Reinforced Concrete On-Site Wastewater Tanks and Pipes《加固混凝土在线污水槽和管道之间回弹性连接器的标准实施规程》.pdf(5页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1644 06Standard Specification forResilient Connectors Between Reinforced Concrete On-SiteWastewater Tanks and Pipes1This standard is issued under the fixed designation C 1644; the number immediately following the designation indicates the year oforiginal adoption or, in the case of re
2、vision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This specification covers the minimum performance andmaterial requirements for resilient connecto
3、rs used for connec-tions between reinforced concrete tanks used for septic effluenttreatment/detention, including those referenced in Specifica-tions C 913 and C 1227.1.1.1 These connectors are designed to eliminate leakagebetween the pipe(s) and tank.1.2 A complete metric companion to Specification
4、 C 1644has been developedC 1644M; therefore, no metric equiva-lents are presented in this specification.NOTE 1This specification covers the design, material, and perfor-mance of the resilient connection only. Connections covered by thisspecification are adequate for hydrostatic pressures up to 5 psi
5、 (11.5 ft)without leakage when tested in accordance with Section 7. Infiltration orexfiltration quantities for an installed system are dependent upon manyfactors other than the connectors between tanks and pipes, and allowablequantities must be covered by other specifications and suitable testing of
6、the installed pipe and system.1.3 The following precautionary caveat pertains only to thetest methods portion, Section 7, of this specification. Thisstandard does not purport to address all of the safety concerns,if any, associated with its use. It is the responsibility of the userof this standard t
7、o establish appropriate safety and healthpractices and determine the applicability of regulatory limita-tions prior to use.2. Referenced Documents2.1 ASTM Standards:2A 240/A 240M Specification for Chromium andChromium-Nickel Stainless Steel Plate, Sheet, and Stripfor Pressure Vessels and for General
8、 ApplicationsC 822 Terminology Relating to Concrete Pipe and RelatedProductsC 913 Specification for Precast Concrete Water and Waste-water StructuresC 1227 Specification for Precast Concrete Septic TanksD 395 Test Methods for Rubber PropertyCompressionSetD 412 Test Methods for Vulcanized Rubber and
9、Thermo-plastic ElastomersTensionD 471 Test Method for Rubber PropertyEffect of LiquidsD 543 Practices for Evaluating the Resistance of Plastics toChemical ReagentsD 573 Test Method for RubberDeterioration in an AirOvenD 624 Test Method for Tear Strength of ConventionalVulcanized Rubber and Thermopla
10、stic ElastomersD 746 Test Method for Brittleness Temperature of Plasticsand Elastomers by ImpactD 883 Terminology Relating to PlasticsD 1149 Test Method for Rubber DeteriorationSurfaceOzone Cracking in a ChamberD 1566 Terminology Relating to RubberD 2240 Test Method for Rubber PropertyDurometerHardn
11、ess3. Terminology3.1 Definitions:3.1.1 Terms relating to plastics and rubber shall be asdefined in Terminologies D 883 and D 1566, respectively.3.1.2 Terms relating to precast concrete tanks, and relatedproducts shall be as defined in Terminology C 822 and asmodified in 3.1.3-3.1.5.3.1.3 connectorth
12、e entire assembly including resilientseals and metallic or nonmetallic mechanical devices, if any,used therein.1This specification is under the jurisdiction ofASTM Committee C27 on PrecastConcrete Structures and is the direct responsibility of Subcommittee C27.30 onPrecast Concrete Septic Tanks and
13、Grease Interceptors.Current edition approved July 1, 2006. Published July 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page o
14、nthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.3.1.4 pipethe inlet or outlet pipe connected to the tank.3.1.5 pipe stuba short section of pipe, installed in thestructure as an inlet or outlet pipe, for future conne
15、ction.4. Materials and Manufacture4.1 All materials shall be suitable for use in sanitary sewageapplications.4.1.1 Resilient MaterialsResilient materials for connec-tors shall be manufactured from natural or synthetic materialsand shall conform to the requirements prescribed in Table 1and 4.1. If a
16、splice is used in the manufacture of the seal, itsstrength shall be such that the splice can withstand a 180 bendwith no visible separation.4.1.2 Mechanical DevicesExpansion rings, tension bands,and take-up devices used for mechanically compressing theresilient portion of the connector against the p
17、ipe, or tank shallbe made from a material or materials in combination that willensure durability, strength, resistance to corrosion, and haveproperties that will ensure continued resistance to leakage. Allmetallic mechanical devices, including castings and bolt as-semblies used in or with the connec
18、tor shall be constructed ofseries 300 stainless steel in accordance with SpecificationA 240.NOTE 2Experience has shown that successful performance of thisproduct depends on the type of bedding and backfill and the care in thefield installation of the tank and connecting pipes. The owner is cautioned
19、to require inspection at the construction site.5. Principles of Design5.1 The design of the connector shall be such that positiveseal is accomplished at two locations: (1) between the connec-tor and the tank and (2) between the connector and the pipe.The seal between the connector and the tank, and
20、between theconnector and the pipe, may be made by any suitable anddurable means, provided that it meets the requirements of Table1 and Section 7.5.2 Purchaser shall require that all pipe stubs installed, toallow for future connection to the structure, be mechanicallyrestrained from movement by means
21、 of, and in addition to, theresilient connectors.6. Basis of Acceptance6.1 Each connector design shall be tested in accordancewith the requirements of Section 7. For connectors into whichmore than one pipe size may be installed, each pipe size shallbe tested independently.6.2 The acceptability of th
22、e resilient connector shall bedetermined by the results of the physical tests prescribed in thisspecification, and by inspection, to determine whether theconnector conforms to the specification with regards to designand freedom from defects.6.3 When requested, a current certification shall be fur-ni
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16442006STANDARDSPECIFICATIONFORRESILIENTCONNECTORSBETWEENREINFORCEDCONCRETEONSITEWASTEWATERTANKSANDPIPES

链接地址:http://www.mydoc123.com/p-465390.html