《ASTM C1635-2006 Standard Test Method to Evaluate Adhesion Cohesion Properties of a Sealant at Fixed Extension《在固定范围内密封剂粘结特性评价的标准试验方法》.pdf》由会员分享,可在线阅读,更多相关《ASTM C1635-2006 Standard Test Method to Evaluate Adhesion Cohesion Properties of a Sealant at Fixed Extension《在固定范围内密封剂粘结特性评价的标准试验方法》.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1635 06Standard Test Method toEvaluate Adhesion/Cohesion Properties of a Sealant atFixed Extension1This standard is issued under the fixed designation C 1635; the number immediately following the designation indicates the year oforiginal adoption or, in the case of revision, the year
2、of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method describes a laboratory procedure formeasuring the adhesion/cohesion properties of a sealant whens
3、ubjected to tensile loads resulting from an applied specifiedstrain. The adhesion/cohesion properties are evaluated before,during, and after water immersion.1.2 This test method examines the adhesive and cohesiveperformance of a sealant on a specified substrate at a strainequivalent to a multiple of
4、 the strain/movement capabilitydesignated by the manufacturer for the given sealant perSpecification C 920.1.3 The values stated in SI (metric) units are to be regardedas the standard. The inch values given in parentheses are forinformation only.1.4 This standard does not purport to address all of t
5、hesafety concerns, if any associated with its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.5 Comparable Test:1.5.1 ISO 10590, Building construction - Jointing
6、products- Sealants - Determination of adhesion/cohesion properties atmaintained extension after immersion in water1.5.2 ISO 8340, Building construction - Jointing products -Sealants - Determination of tensile properties at maintainedextension2. Referenced Documents2.1 ASTM Standards:2C 717 Terminolo
7、gy of Building Seals and SealantsC 719 Test Method for Adhesion and Cohesion of Elasto-meric Joint Sealants Under Cyclic Movement (HockmanCycle)C 920 Specification for Elastomeric Joint SealantsC 1375 Guide for Substrates Used in Testing Building Sealsand Sealants3. Terminology3.1 Definitions:3.1.1
8、casting spacersthe spacers used in the fabrication ofthe joints made from wet sealant3.1.2 separatorsthe device or item used to maintain thespecimens at fixed extension.4. Summary of Test Method4.1 Test specimens made in accordance with dimensions setforth in Test Method C 719 are fabricated and all
9、owed to cure.4.2 Test specimens are extended at standard conditions to aspecified strain and blocked at the strain for a specified periodof time.4.3 The test specimens are examined for adhesive or cohe-sive failure, or both, of the sealant at 0, 24 and 168 h.4.4 A duplicate set of three test specime
10、ns are cured atstandard conditions, extended to a specified strain, and thenimmersed (totally) in deionized water or specified medium (3specimens/liter of liquid).4.5 Immersed test specimens are observed at 0, 24 and 168and other additional specified hours.4.6 This test method uses ASTM standard sub
11、strates asdescribed in Guide C 1375. This test method does not excludethe use of any other substrate that provides a suitable flatsurface.5. Significance and Use5.1 In any sealant application, the sealant must be capable ofmaintaining an adhesive bond to the substrate when held instrain for its inte
12、nded service life.5.2 This test method is an indicator of a sealants ability toadhere under strain to a given substrate.1This test method is under the jurisdiction ofASTM Committee C24 on BuildingSeals and Sealants and is the direct responsibility of Subcommittee C24.30 onAdhesionCurrent edition app
13、roved Jan. 1, 2006. Published February 2006.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM I
14、nternational, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.5.3 The default test strain is the movement ability of thesealant as designated by the manufacturer. The default jointconfiguration is 12.7 3 12.7 3 50.8 mm (12 312 3 2 in.).Other strains and joint conf
15、igurations may be used and reportedas noted in Section 8 and Table 1.6. Apparatus and Materials6.1 Container, for immersion made of a material compatiblewith the immersion medium.6.2 Device, to provide a strain on the test specimen.6.3 Spatulas, for use in applying the sealant.6.4 Caulking Gun, for
16、extruding sealant from cartridgeswhen applicable.6.5 SubstratesTwelve substrates minimum of 25.4 3 76.2mm (1 3 3 in.) of the same finish are required for each testsample.6.6 Casting SpacersMade from polytetrafluoroethylene(PTFE) or a suitable rigid material shall be used with each testspecimen to wh
17、ich the test sealant will not bond and willprovide the appropriate joint dimensions and configurations.6.7 Substrate Cleaning Materials:6.8 Primer (if needed).6.9 Separators, to provide a constant strain on the specimenwhilst maintaining parallel bond surfaces.6.10 Deionized Water, or other specifie
18、d liquid medium forimmersion6.11 Suitable Probe Type Measuring Device, capable ofmeasuring defects in the sealant to 1 mm (132 in.)7. Procedure7.1 Preparation of Test Specimens. Six test specimens.7.1.1 Standard conditions of temperature and relative hu-midity used throughout this test method are de
19、fined as inTerminology C 717.7.1.2 Clean the substrates per the procedures set forth inTest Method C 719 and Guide C 1375.7.1.3 PrimersWhere use of primer is recommended bythe sealant manufacturer, substrate materials shall be primedwith the recommended primer or primers.7.1.4 Apply a bead of sealan
20、t 12.7 3 12.7 3 50.8 mm (12312 3 2 in.) between parallel 25.4 3 76.2 mm (1 3 3 in.)substrates (or of other desired dimensions and noted in thereport). Use appropriate casting spacers to form the proper sizebead. Use adhesive tape, rubber bands, or clamps to hold thetest assembly together before and
21、after filling it with thesealant. In the case of a pourable-type sealant, use masking orany other suitable tape to retain the sealant. Use masking tapeon top surface of substrates to prevent sealant from curing onthe top surface. Remove the tape immediately following fillingthe specimen joint cavity
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16352006STANDARDTESTMETHODTOEVALUATEADHESIONCOHESIONPROPERTIESOFASEALANTATFIXEDEXTENSION 固定 范围内

链接地址:http://www.mydoc123.com/p-465372.html