ASTM C1617-2009 Standard Practice for Quantitative Accelerated Laboratory Evaluation of Extraction Solutions Containing Ions Leached from Thermal Insulation on Aqueous Corrosion of.pdf
《ASTM C1617-2009 Standard Practice for Quantitative Accelerated Laboratory Evaluation of Extraction Solutions Containing Ions Leached from Thermal Insulation on Aqueous Corrosion of.pdf》由会员分享,可在线阅读,更多相关《ASTM C1617-2009 Standard Practice for Quantitative Accelerated Laboratory Evaluation of Extraction Solutions Containing Ions Leached from Thermal Insulation on Aqueous Corrosion of.pdf(11页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C1617 09Standard Practice forQuantitative Accelerated Laboratory Evaluation ofExtraction Solutions Containing Ions Leached from ThermalInsulation on Aqueous Corrosion of Metals1This standard is issued under the fixed designation C1617; the number immediately following the designation in
2、dicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon () indicates an editorial change since the last revision or reapproval.1. Scope1.1 This practice covers procedures for a qu
3、antitative accel-erated laboratory evaluation of the influence of extractionsolutions containing ions leached from thermal insulation onthe aqueous corrosion of metals. The primary intent of thepractice is for use with thermal insulation and associatedmaterials that contribute to, or alternatively i
4、nhibit, the aqueouscorrosion of different types and grades of metals due to solubleions that are leached by water from within the insulation. Thequantitative evaluation criteria are Mass Loss Corrosion Rate(MLCR) expressed in mils per year determined from theweight loss due to corrosion of exposed m
5、etal coupons afterthey are cleaned.1.2 The insulation extraction solutions prepared for use inthe test can be altered by the addition of corrosive ions to thesolutions to simulate contamination from an external source.Ions expected to provide corrosion inhibition can be added toinvestigate their inh
6、ibitory effect.1.3 Prepared laboratory standard solutions are used asreference solutions and controls, to provide a means ofcalibration and comparison. See Fig. 1 and Table 1.1.4 Other liquids can be tested for their potential corrosive-ness including cooling tower water, boiler feed, and chemicalst
7、ocks. Added chemical inhibitors or protective coatings ap-plied to the metal can also be evaluated using the generalguidelines of the practice.1.5 This practice cannot cover all possible field conditionsthat contribute to aqueous corrosion. The intent is to provide anaccelerated means to obtain a no
8、n-subjective numeric value forjudging the potential contribution to the corrosion of metalsthat can come from ions contained in thermal insulationmaterials or other experimental solutions. The calculatednumeric value is the mass loss corrosion rate. This calculationis based on general corrosion spre
9、ad equally over the testduration and the exposed area of the experimental cells createdfor the test. Corrosion found in field situations and thisaccelerated test also involves pitting and edge effects and therate changes over time.1.6 The values stated in inch-pound units are to be regardedas standa
10、rd. The values given in parentheses are mathematicalconversions to SI units that are provided for information onlyand are not considered standard.1.7 This standard does not purport to address all of thesafety concerns, if any, associated with its use. It is theresponsibility of the user of this stan
11、dard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.2. Referenced Documents2.1 ASTM Standards:2A53/A53M Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and SeamlessA105/A105M Specification for Car
12、bon Steel Forgings forPiping ApplicationsC168 Terminology Relating to Thermal InsulationC518 Test Method for Steady-State Thermal TransmissionProperties by Means of the Heat Flow Meter ApparatusC665 Specification for Mineral-Fiber Blanket Thermal In-sulation for Light Frame Construction and Manufact
13、uredHousingC692 Test Method for Evaluating the Influence of ThermalInsulations on External Stress Corrosion Cracking Ten-dency of Austenitic Stainless SteelC739 Specification for Cellulosic Fiber Loose-Fill ThermalInsulationC795 Specification for Thermal Insulation for Use in Con-tact with Austeniti
14、c Stainless SteelC871 Test Methods for Chemical Analysis of ThermalInsulation Materials for Leachable Chloride, Fluoride,Silicate, and Sodium IonsD609 Practice for Preparation of Cold-Rolled Steel Panelsfor Testing Paint, Varnish, Conversion Coatings, and1This practice is under the jurisdiction of A
15、STM Committee C16 on ThermalInsulation and is the direct responsibility of Subcommittee C16.31 on Chemical andPhysical Properties.Current edition approved Nov. 1, 2009. Published November 2009Originallyapproved in 2005. Last previous edition approved in 2005 as C161705. DOI:10.1520/C1617-09.2For ref
16、erenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annual Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, We
17、st Conshohocken, PA 19428-2959, United States.Related Coating ProductsG1 Practice for Preparing, Cleaning, and Evaluating Corro-sion Test SpecimensG16 Guide for Applying Statistics to Analysis of CorrosionDataG31 Practice for Laboratory Immersion Corrosion Testingof MetalsG46 Guide for Examination a
18、nd Evaluation of PittingCorrosion3. Terminology3.1 Definitions:Refer to Terminology C168 for definitions relating to insu-lation.4. Summary of Practice4.1 The practice uses controlled amounts of test solutionsdelivered drip wise onto a defined area of small flat coupons ofselected test metals for th
19、e purpose of producing, comparing,and measuring the corrosion that occurs on the metals due tothe exposure. Preparation of the coupons includes sanding toremove oxidation and contamination and making the surfaceuniform and reproducible.4.2 The test is conducted at elevated temperatures, greatlyaccel
20、erating the corrosion in comparison with corrosion atroom temperature. The heat makes the solution evaporatequickly, allowing an air (oxygen) interface and making thou-sands of wet-dry-wet cycles possible in a short time.4.3 Quantitative measurements of corrosion are determinedfrom the weight change
21、 (loss) due to the corrosion of the testedNOTE 1The Fig. 1 bar graph was created using the MLCR data shown in Table 2. Standard reference tests using de-ionized water, 1 ppm, 5 ppm,and 10 ppm chloride solutions were performed on mild carbon steel coupons. The calculated MLCR test results for mild ca
22、rbon steel coupons wereseparated into four ranges. The rating criteria ranges were developed to accommodate the results obtained using this practice on the reference standardsand experimental insulation samples. The ranges used are: MLCR=0to15mils = range A; MLCR = 15.1 to 35 mils = range B; MLCR =
23、35.1 to 60mils = range C, MLCR = 60.1 and higher = range D. The bars on the graph represent the total number of occurrences within the range for each of thereference solutions.NOTE 2It is necessary for each laboratory to develop their own data, with their own individual plate or plates, metal, opera
24、tors, cleaning procedures,and environmental conditions to establish the ranges of MLCR calculated for the reference standards. The insulation or other test solutions are thenevaluated against the reference solution results.FIG. 1 Standard Reference TestsC1617 092coupons. Reference tests prepared wit
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC16172009STANDARDPRACTICEFORQUANTITATIVEACCELERATEDLABORATORYEVALUATIONOFEXTRACTIONSOLUTIONSCONTAININGIONSLEACHEDFROMTHERMALINSULATIONONAQUEOUSCORROSIONOFPDF

链接地址:http://www.mydoc123.com/p-465310.html