ASTM C1453-2000(2006) Standard Test Method for the Determination of Uranium by Ignition and the Oxygen to Uranium (O U) Atomic Ratio of Nuclear Grade Uranium Dioxide Powders and Pe.pdf
《ASTM C1453-2000(2006) Standard Test Method for the Determination of Uranium by Ignition and the Oxygen to Uranium (O U) Atomic Ratio of Nuclear Grade Uranium Dioxide Powders and Pe.pdf》由会员分享,可在线阅读,更多相关《ASTM C1453-2000(2006) Standard Test Method for the Determination of Uranium by Ignition and the Oxygen to Uranium (O U) Atomic Ratio of Nuclear Grade Uranium Dioxide Powders and Pe.pdf(3页珍藏版)》请在麦多课文档分享上搜索。
1、Designation: C 1453 00 (Reapproved 2006)Standard Test Method forthe Determination of Uranium by Ignition and the Oxygen toUranium (O/U) Atomic Ratio of Nuclear Grade UraniumDioxide Powders and Pellets1This standard is issued under the fixed designation C 1453; the number immediately following the de
2、signation indicates the year oforiginal adoption or, in the case of revision, the year of last revision. A number in parentheses indicates the year of last reapproval. Asuperscript epsilon (e) indicates an editorial change since the last revision or reapproval.1. Scope1.1 This test method covers the
3、 determination of uraniumand the oxygen to uranium atomic ratio in nuclear gradeuranium dioxide powder and pellets.1.2 This test method does not include provisions for pre-venting criticality accidents or requirements for health andsafety. Observance of this test method does not relieve the userof t
4、he obligation to be aware of and conform to all interna-tional, national, or federal, state and local regulations pertain-ing to possessing, shipping, processing, or using source orspecial nuclear material.1.3 This standard does not purport to address all of thesafety concerns, if any, associated wi
5、th its use. It is theresponsibility of the user of this standard to establish appro-priate safety and health practices and determine the applica-bility of regulatory limitations prior to use.1.4 This test method also is applicable to UO3and U3O8powder.2. Referenced Documents2.1 ASTM Standards:2C 696
6、 Test Methods for Chemical, Mass Spectrometric, andSpectrochemical Analysis of Nuclear-Grade Uranium Di-oxide Powders and PelletsC 753 Specification for Nuclear-Grade, Sinterable UraniumDioxide PowderC 776 Specification for Sintered Uranium Dioxide PelletsC 1267 Test Method for Uranium by Iron (II)
7、Reduction inPhosphoric Acid Followed by Chromium (VI) Titration inthe Presence of VanadiumC 1287 Test Method for Determination of Impurities inNuclear Grade Uranium Compounds by InductivelyCoupled Plasma Mass Spectrometry3. Summary of Test Method3.1 A weighed portion of UO2is converted to U3O8byrepe
8、ated ignition at 900C in air, to a constant weight.Corrections are made for nonvolatile and volatile impuritiesincluding moisture, based on independent determinations de-scribed in Test Methods C 696 and C 1287.3,44. Significance and Use4.1 The test method is designed to show whether or not amateria
9、l meets the specifications as given in SpecificationsC 753 or C 776.4.2 The powders stoichiometry is useful for predicting theoxides sintering behavior in the pellet production process.5. Interferences5.1 The moisture content must be determined and a correc-tion must be made for the moisture content
10、 otherwise a highbias will occur for the O/U ratio.5.2 A nonvolatile impurity correction must be made other-wise a high bias will occur for the uranium value.An extendedignition time may be required if significant amounts of anionsthat are difficult to decompose are present.5.3 The U3O8to uranium co
11、nversion factor and the uraniumatomic weight will require adjustment for nonnatural isotopicconcentrations otherwise a bias will be present.6. Apparatus6.1 Desiccator, containing a moisture absorbent.6.2 Muffle Furnace, capable of maintaining and controllingtemperatures to 900 6 25C.6.3 Analytical B
12、alance, capable of weighing to 6 0.1 mg.6.4 Platinumware.7. Reagents and Materials7.1 Anhydrous magnesium perchlorate Mg (ClO4)2, mois-ture absorbent, or equivalent.1This test method is under the jurisdiction of ASTM committee C26 on NuclearFuel Cycle and is the direct responsibility of Subcommittee
13、 C26.05 on Methods ofTest.Current edition approved July 1, 2006. Published September 2006. Originallyapproved in 2000. Last previous edition approved in 2000 as C 145300.2For referenced ASTM standards, visit the ASTM website, www.astm.org, orcontact ASTM Customer Service at serviceastm.org. For Annu
14、al Book of ASTMStandards volume information, refer to the standards Document Summary page onthe ASTM website.3Jones, R.J., Ed., “Selected Measurement Methods for Plutonium and Uraniumin the Nuclear Fuel Cycle,” USAEC Document TID-7029, 1963, AERDB, pp.9193.4Petit, G.D. and Keinberger, C.A., “Prepara
15、tion of Stoichiometric U3O8,”Analytical Chemistry, ANCHA Vol 25, 1961, p. 579.1Copyright ASTM International, 100 Barr Harbor Drive, PO Box C700, West Conshohocken, PA 19428-2959, United States.8. Procedure8.1 Transfer 2 to 12 g of UO2powder or pellets to a taredplatinum crucible and weigh to within
16、0.1 mg.8.1.1 UO2PowderPlace the platinum crucible containingthe UO2powder sample in a muffle furnace and ignite for 3 hat 900 6 25C.8.1.2 UO2PelletsPreheat the pellets at 500C for 3 h, inthe muffle furnace, then ignite for3hat9006 25C.8.2 Remove the crucible from the furnace, allow to cool inthe air
17、 2 to 3 minutes, then place the crucible in a desiccatorand cool to room temperature. Weigh the crucible.8.3 Repeat the ignition for 3 h at 900C and repeat step 8.2until a constant weight of 6 0.3 mg is obtained.8.4 Other ignition and cooling schemes may be used as longas the analyst verifies the pr
18、ecision and the bias of themeasurement.9. Calculation9.1 Uranium ContentCalculate as follows:U, wt% 5 0.8480 W 2 WI!/S! X 100 2 C (1)where:0.8480 = U3O8to uranium conversion factor for naturaluranium.This factor will require adjustment whenthe uranium isotopic abundance deviates fromnatural uranium.
19、 See Appendix X1.2.W = Grams of U3O8after ignition.I = Total of all detected nonvolatile impurities ex-pressed as grams of oxide per gram of ignitedU3O8. See Table 1 to obtain oxide conversionfactors for many common impurity elements en-countered. The impurities are determined as de-scribed in eithe
- 1.请仔细阅读文档,确保文档完整性,对于不预览、不比对内容而直接下载带来的问题本站不予受理。
- 2.下载的文档,不会出现我们的网址水印。
- 3、该文档所得收入(下载+内容+预览)归上传者、原创作者;如果您是本文档原作者,请点此认领!既往收益都归您。
下载文档到电脑,查找使用更方便
10000 积分 0人已下载
下载 | 加入VIP,交流精品资源 |
- 配套讲稿:
如PPT文件的首页显示word图标,表示该PPT已包含配套word讲稿。双击word图标可打开word文档。
- 特殊限制:
部分文档作品中含有的国旗、国徽等图片,仅作为作品整体效果示例展示,禁止商用。设计者仅对作品中独创性部分享有著作权。
- 关 键 词:
- ASTMC145320002006STANDARDTESTMETHODFORTHEDETERMINATIONOFURANIUMBYIGNITIONANDTHEOXYGENTOURANIUMOUATOMICRATIOOFNUCLEARGRADEURANIUMDIOXIDEPOWDERSANDPEPDF

链接地址:http://www.mydoc123.com/p-464715.html